IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)

Demonstration of a Robust Hybrid Classical/Quantum Accelerometer

P. Cheiney, B. Barrett, Simon Templier, Olivier Jolly, Baptiste Battelier, Philippe Bouyer, Henri Porte, Fabien Napolitano

Published Apr 1, 2019• 11 citations
Publisher

Abstract

We present a hybrid accelerometer that combines the large bandwidth and dynamic range of a mechanical accelerometer with the extreme stability of a quantum accelerometer based on cold atom interferometry. We describe our experimental setup and hybridization algorithm and, to assess the performances of the apparatus, we simulate a mobile environment in the laboratory by adding simultaneously vibration noise, temperature variations and laser intensity fluctuations. Even under these conditions, we are able to track the accelerometer bias to less than 1 μg. In a normal laboratory environment, our hybrid accelerometer then reaches a precision of 10 ng after 11 hours of integration. Finally, we present a novel system that compensates in real-time phase shifts due to vibrations and Doppler shifts that occur when changing the AI orientation. This allows us to operate optimally the atom interferometer in an arbitrary direction, opening the way toward truly mobile operation.

DOI
10.1109/isiss.2019.8739762

Related papers

A three-axis quantum accelerometer for mobile sensing applications

Baptiste Battelier, P. Cheiney, B. Barrett +6 more

We present a mobile 3D accelerometer based on matter-wave interferometry, which is capable of measuring three orthogonal accelerations, each with respect to an independent inertial reference frame defined by the surface of a mirror. On each axis, we construct a hybrid quantum/classical accelerometer by using correlations between the atoms and a mechanical accelerometer attached to the back of each reference mirror. This system combines the large bandwidth and dynamic range of classical devices with the high sensitivity and accuracy of atom interferometers. By correcting each classical accelerometer independently, we are able to track the full acceleration vector with high accuracy.

•Oct 2, 2020•3 citations

Hybrid quantum sensing using an optomechanical resonator coupled atom interferometer

Ashwin Rajagopalan

Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.

•Jan 1, 2026•0 citations

Optomechanical inertial reference for atom interferometry

A. Rajagopalan, K. Stolzenberg, D. Thomas +5 more

Atom interferometers are among the most sensitive inertial sensors, yet deployment outside the laboratory is limited by vibration noise, conventionally mitigated by external sensors or bulky isolation. Here we demonstrate a hybrid inertial sensor which fuses an optomechanical resonator and an atom interferometer by exploiting the resonator's test mass as the interferometer's reference mirror. This allows for better correlation than with two separate sensors, whose unknown transfer function is replaced by the static response of one mechanical element. The resonator achieves a displacement sensitivity of $8.6\cdot 10^{-15}$ m/$\sqrt{\mathrm{Hz}}$ with suppressed 1/f noise and yields a minimum acceleration sensitivity of $1.1\cdot10^{-6}$ m/s$^2$/$\sqrt{\mathrm{Hz}}$ over a bandwidth extending from sub-Hertz to 2.5 kHz. Under ambient laboratory conditions the integrated system removes vibration-induced phase ambiguity for accelerations up to $50\cdot 10^{-3}$ m/s$^2$ and reaches the interferometer's technical noise limit, which a commercial force-balance accelerometer does not. Because the resonance-tracking readout is largely independent of the mechanical design, the architecture transfers directly to other precision sensing platforms.

quant-pharXiv:2608.28418•Aug 31, 2026

Atom interferometry at arbitrary orientations and rotation rates

Quentin d’Armagnac de Castanet, Cyrille Des Cognets, Romain Arguel +6 more

The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.

arXiv:2402.18988•Nature Communications•Jul 30, 2024•35 citations

Tracking the vector acceleration with a hybrid quantum accelerometer triad

Simon Templier, P. Cheiney, Quentin d’Armagnac de Castanet +6 more

Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold atom–based quantum inertial sensors can potentially provide these high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultralow bias permits tracking the acceleration vector over long time scales, yielding a 50-fold improvement in stability (6 × 10 −8 g ) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 μ g , and pointing accuracy of 4 μrad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units.

arXiv:2209.13209•Science Advances•Nov 9, 2022•73 citations

Development of compact cold-atom sensors for inertial navigation

Baptiste Battelier, B. Barrett, Lauriane Fouché +7 more

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.

arXiv:1605.02454•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•84 citations
We present a hybrid accelerometer that combines the large bandwidth and dynamic range of a mechanical accelerometer with the extreme stability of a quantum accelerometer based on cold atom interferometry. We describe our experimental setup and hybridization algorithm and, to assess the performances of the apparatus, we simulate a mobile environment in the laboratory by adding simultaneously vibration noise, temperature variations and laser intensity fluctuations. Even under these conditions, we are able to track the accelerometer bias to less than 1 μg. In a normal laboratory environment, our hybrid accelerometer then reaches a precision of 10 ng after 11 hours of integration. Finally, we present a novel system that compensates in real-time phase shifts due to vibrations and Doppler shifts that occur when changing the AI orientation. This allows us to operate optimally the atom interferometer in an arbitrary direction, opening the way toward truly mobile operation.
We present a mobile 3D accelerometer based on matter-wave interferometry, which is capable of measuring three orthogonal accelerations, each with respect to an independent inertial reference frame defined by the surface of a mirror. On each axis, we construct a hybrid quantum/classical accelerometer by using correlations between the atoms and a mechanical accelerometer attached to the back of each reference mirror. This system combines the large bandwidth and dynamic range of classical devices with the high sensitivity and accuracy of atom interferometers. By correcting each classical accelerometer independently, we are able to track the full acceleration vector with high accuracy.
Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.
Atom interferometers are among the most sensitive inertial sensors, yet deployment outside the laboratory is limited by vibration noise, conventionally mitigated by external sensors or bulky isolation. Here we demonstrate a hybrid inertial sensor which fuses an optomechanical resonator and an atom interferometer by exploiting the resonator's test mass as the interferometer's reference mirror. This allows for better correlation than with two separate sensors, whose unknown transfer function is replaced by the static response of one mechanical element. The resonator achieves a displacement sensitivity of 8.6⋅10−158.6\cdot 10^{-15}8.6⋅10−15 m/Hz\sqrt{\mathrm{Hz}}Hz​ with suppressed 1/f noise and yields a minimum acceleration sensitivity of 1.1⋅10−61.1\cdot10^{-6}1.1⋅10−6 m/s2^22/Hz\sqrt{\mathrm{Hz}}Hz​ over a bandwidth extending from sub-Hertz to 2.5 kHz. Under ambient laboratory conditions the integrated system removes vibration-induced phase ambiguity for accelerations up to 50⋅10−350\cdot 10^{-3}50⋅10−3 m/s2^22 and reaches the interferometer's technical noise limit, which a commercial force-balance accelerometer does not. Because the resonance-tracking readout is largely independent of the mechanical design, the architecture transfers directly to other precision sensing platforms.
The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.
Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold atom–based quantum inertial sensors can potentially provide these high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultralow bias permits tracking the acceleration vector over long time scales, yielding a 50-fold improvement in stability (6 × 10 −8 g ) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 μ g , and pointing accuracy of 4 μrad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units.
Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.