Journal of Magnetism and Magnetic Materials

Relaxation time dependencies of optically detected magnetic resonance harmonics in highly sensitive Mx magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi, S.M.H. Khalkhali

Published Sep 8, 2018• 15 citations
Publisher
DOI
10.1016/j.jmmm.2018.09.031

Related papers

Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi +1 more

Journal of Magnetism and Magnetic Materials•Oct 16, 2016•18 citations

A rubidium Mx-magnetometer for measurements on solid state spins

Daniel Arnold, Steven Siegel, Emily Grisanti +2 more

The detection of environmental magnetic fields is well established by optically pumped atomic magnetometers. Another focus of magnetometry can be the research on magnetic or spin-active solid-state samples. Here we introduce a simple and compact design of a rubidium-based Mx magnetometer, which allows for hosting solid-state samples. The optical, mechanical, and electrical design is reported, as well as simple measurements which introduce the ground-state spin-relaxation time, the signal-to-noise ratio of a measurement, and subsequently the overall sensitivity of the magnetometer. The magnetometer is optimized for the most sensitive operation with respect to laser power and magnetic field excitation at the Larmor frequency.

arXiv:1610.09956•Review of Scientific Instruments•Feb 1, 2017•16 citations

Noise spectroscopy of nonlinear magneto-optical resonances

Lezana, Valente, Failache +4 more

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

High-accuracy CPT-based atomic magnetometer with compact optical and electronic architecture

Ruochen Zhang, Renfeng Dai, Hua Liu

We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.

Optics Letters•Sep 23, 2025•1 citation

Optical Analogs of Magnetic Resonance Spectroscopy

J. I. Steinfeld

Elsevier eBooks•Jan 1, 1974•2 citations

Effects of spin-destruction and spin-exchange collisions on alkali-metal relaxation and magnetometric response

Feng Tang, Jianjun Li, Nan Zhao

Abstract Spin-exchange (SE) and spin-destruction (SD) collisions play a central role in determining the coherence properties of alkali-metal vapors and the performance of alkali-metal magnetometers in external magnetic fields. In this work, we investigate how these collisions influence spin relaxation dynamics and magnetometric response using a generalized Bloch equation that fully accounts for the coupled evolution of spin polarizations in different hyperfine manifolds. Our results show that in the low-field regime, both SE and SD collisions contribute to the suppression of transverse spin relaxation and the slowdown of spin precession, whereas longitudinal relaxation depends weakly on the SE rate and is predominantly governed by SD interactions. Building on the established relationship between spin relaxation rates and magnetometric response, we further analyze how SE and SD collisions affect the performance of two representative magnetometer architectures: the spin-exchange relaxation-free (SERF) magnetometer and the magnetic-resonance Mx-type magnetometer. The SERF magnetometer’s response is found to be primarily determined by the SD rate, with only minor dependence on the nuclear spin quantum number. In contrast, the magnetic-resonance Mx-type magnetometer’s sensitivity is significantly affected by both the magnetic field strength and the SE rate. While the resonance linewidth decreases with reduced magnetic field, the associated measurement accuracy deteriorates markedly. Consequently, reliable magnetic field reconstruction is only achievable in the high-field regime, where the Larmor frequency greatly exceeds the SE rate.

Chinese Physics B•Jan 14, 2026•0 citations
The detection of environmental magnetic fields is well established by optically pumped atomic magnetometers. Another focus of magnetometry can be the research on magnetic or spin-active solid-state samples. Here we introduce a simple and compact design of a rubidium-based Mx magnetometer, which allows for hosting solid-state samples. The optical, mechanical, and electrical design is reported, as well as simple measurements which introduce the ground-state spin-relaxation time, the signal-to-noise ratio of a measurement, and subsequently the overall sensitivity of the magnetometer. The magnetometer is optimized for the most sensitive operation with respect to laser power and magnetic field excitation at the Larmor frequency.
We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.
Abstract Spin-exchange (SE) and spin-destruction (SD) collisions play a central role in determining the coherence properties of alkali-metal vapors and the performance of alkali-metal magnetometers in external magnetic fields. In this work, we investigate how these collisions influence spin relaxation dynamics and magnetometric response using a generalized Bloch equation that fully accounts for the coupled evolution of spin polarizations in different hyperfine manifolds. Our results show that in the low-field regime, both SE and SD collisions contribute to the suppression of transverse spin relaxation and the slowdown of spin precession, whereas longitudinal relaxation depends weakly on the SE rate and is predominantly governed by SD interactions. Building on the established relationship between spin relaxation rates and magnetometric response, we further analyze how SE and SD collisions affect the performance of two representative magnetometer architectures: the spin-exchange relaxation-free (SERF) magnetometer and the magnetic-resonance Mx-type magnetometer. The SERF magnetometer’s response is found to be primarily determined by the SD rate, with only minor dependence on the nuclear spin quantum number. In contrast, the magnetic-resonance Mx-type magnetometer’s sensitivity is significantly affected by both the magnetic field strength and the SE rate. While the resonance linewidth decreases with reduced magnetic field, the associated measurement accuracy deteriorates markedly. Consequently, reliable magnetic field reconstruction is only achievable in the high-field regime, where the Larmor frequency greatly exceeds the SE rate.