Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Towards an 27Al+ based optical clock

Ksenia Yu. Khabarova, Ilia V. Zalivako, Ilya A. Semerikov, Borisenko Alexander, Kolachevsky Nikolay

Published Apr 1, 2018• 3 citations
Publisher

Abstract

We present current status of a project aimed for development of an optical clock based on27Al+ ion and auxiliary25Mg+ ion started at LPI. Results on Mg+ ions trapping and cooling are presented as well as a clock laser design.
DOI
10.1109/eftf.2018.8409073

Related papers

Towards an 27Al+ ions optical clock

Zetian Xu, Xiaoyi Zeng, Xiaohui Shi +4 more

Magnesium ion which acts as the logic ion in27Al+ion optical clock is trapped and laser cooled in a linear ion trap. Rabi oscillation between two hyperfine ground states of25Mg+ion is observed and resonant frequency between two hyperfine ground states of25Mg+ion is measured. Earth magnetic field is compensated with three pairs of mutually perpendicular Helmholtz coils. Light shift induced by the Raman cooling beams is measured. With the photo-ionization laser of Al, Al+ion is trapped together with Mg+ion. The linewidth of the clock laser of the27Al+ion is measured to be about 0.8 Hz. The Allan deviation of the beat note from two independent lasers is 6.5×10-15at 1s.

European Frequency and Time Forum•Jun 1, 2014•0 citations

Recent progress on the27Al+ion optical clock

Zhilin Xu, W. H. Yuan, Xiangbin Zeng +5 more

An aluminium ion optical clock is under development at Huazhong University of Science and Technology. The 25 Mg + ion is chosen as logic ion to sympathetically cool an Al + ion and to detect its states. The 25 Mg + ion is cooled to the motional ground state through Raman sideband cooling as the first step for quantum logic spectroscopy. Ultra-stable lasers for the interrogation of the clock transition are developed. The instability of the laser beat frequency is 1.2 x 10 -15 at 1 s, which is close to the thermal noise limit of the reference cavity.

Journal of Physics Conference Series•Jun 1, 2016•8 citations

Progress report of an 27Al+ ion optical clock

Ke Deng, Zhilin Xu, W. H. Yuan +6 more

An Al+ion optical clock is under development at Huazhong University of Science and Technology in China. We have successfully crystallized Magnesium ions. Through micromotion compensation and trapping parameters optimization, temperature of a trapped single ion is lowered to be around 19 mK.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•0 citations

Compact Yb+optical atomic clock project: design principle and current status

Clément Lacroûte, Maël Souidi, Pierre-Yves Bourgeois +6 more

We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.

arXiv:1603.05816•Journal of Physics Conference Series•Jun 1, 2016•24 citations

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•47 citations

Towards compact transportable optical clock based on 171Yb+

Ilia V. Zalivako, Ksenia Yu. Khabarova, Ilya A. Semerikov +7 more

We report on a new project aimed for development of a transportable compact optical clock based on single171Yb+ion trapped in a ion Paul trap. The goal is to reach relative frequency instability level of 5E-16 at 24 hours averaging time.

European Frequency and Time Forum•Apr 1, 2018•1 citation
Magnesium ion which acts as the logic ion in27Al+ion optical clock is trapped and laser cooled in a linear ion trap. Rabi oscillation between two hyperfine ground states of25Mg+ion is observed and resonant frequency between two hyperfine ground states of25Mg+ion is measured. Earth magnetic field is compensated with three pairs of mutually perpendicular Helmholtz coils. Light shift induced by the Raman cooling beams is measured. With the photo-ionization laser of Al, Al+ion is trapped together with Mg+ion. The linewidth of the clock laser of the27Al+ion is measured to be about 0.8 Hz. The Allan deviation of the beat note from two independent lasers is 6.5×10-15at 1s.
An aluminium ion optical clock is under development at Huazhong University of Science and Technology. The 25 Mg + ion is chosen as logic ion to sympathetically cool an Al + ion and to detect its states. The 25 Mg + ion is cooled to the motional ground state through Raman sideband cooling as the first step for quantum logic spectroscopy. Ultra-stable lasers for the interrogation of the clock transition are developed. The instability of the laser beat frequency is 1.2 x 10 -15 at 1 s, which is close to the thermal noise limit of the reference cavity.
We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.