We report the evaluation of the systematic shifts and the total uncertainty of an
27Al+ optical clock sympathetically cooled by a
40Ca+ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the
27Al+ ion, the time dilation shift of the secular motion of our
40Ca+−27Al+ clock is smaller than the shift of a
25Mg+−27Al+ clock. The total systematic uncertainty of our
40Ca+−27Al+ quantum logic clock has been estimated to be
7.6×10−18, which was mainly limited by the uncertainty of the quadratic Zeeman shift.
Systematic uncertainty below 10^-18 in the aluminium quantum-logic clock is examined for the NIST aluminium-27 quantum-logic clock, with a published systematic uncertainty of 9.4 parts inside 10^19, the smallest total reported for any clock in its era. Principal computed quantities: total uncertainty e19 = 9.462; published total e19 = 9.4; ratio computed to published = 1.007; motion pair e19 = 6.574; motion share of variance pct = 48.28; height equivalent mm = 8.671. The governing idea, for NIST aluminium-27 quantum-logic clock, runs as follows. A single trapped ion has no density shift and almost no blackbody shift, so its budget is dominated instead by motion: the time-dilation effects of secular motion and excess micromotion, and by the second-order zeeman shift of the trapping field. Setting total uncertainty e19 at 9.462 beside published total e19 at 9.4 shows, for NIST aluminium-27 quantum-logic clock, the scale, for NIST aluminium-27 quantum-logic clock, before interpretation. Both numbers, for NIST aluminium-27 quantum-logic clock, come from the systematic uncertainty below 10^-18 in the aluminium quantum-logic clock relations. The later discussion, for NIST aluminium-27 quantum-logic clock, sets total uncertainty e19 at 9.462 against published values for NIST aluminium-27 quantum-logic clock and names, for NIST aluminium-27 quantum-logic clock, the input moving total uncertainty e19 at 9.462 furthest.
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.