Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Effect of Raman-pulse duration related to the magnetic field gradient in high-precision atom gravimeters

Yuan Sheng Cheng, Yu-Jie Tan, Min-Kang Zhou, Xiao‐Chun Duan, Cheng-Gang Shao, Zhong-Kun Hu

Published Mar 1, 2018• 4 citations
Publisher

Abstract

The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10 −10 g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.

DOI
10.1088/1674-1056/27/3/030303

Related papers

Raman pulse duration effect in high-precision atom interferometry gravimeters

Li Xia, Cheng-Gang Shao, Zhong-Kun Hu

For high-precision atom interferometry gravimeters, the effect of the Raman pulse duration will become an appreciable fraction and need to be taken into account. Its influence has been reported considering a homogeneous Earth’s gravitational field in some previous works. In this paper, by decomposing the time evolution operator into two parts, the free evolution part and the interaction part, we develop an approach to study this effect in a realistic situation where the Earth’s gravitational field is inhomogeneous. A mathematic expression for the interferometer phase shift because of the Raman pulse duration effect is obtained, which shows that the Raman pulse duration should be taken into account when the gravimeter reaches an accuracy of 10−10 g.

Journal of the Optical Society of America B•Jan 12, 2015•20 citations

Improved frequency-shift gravity-gradient compensation on canceling the Raman-pulse-duration effect in atomic gravimeters

Yajie Wang, Xiao-Yu Lu, Yu-Jie Tan +2 more

Although frequency-shift gravity-gradient compensation is currently the technique with the most potential to test the weak equivalence principle with atom interferometry at high precision, it faces an unavoidable obstacle on how to cancel the coupling between the Raman-pulse-duration effect and the gravity gradient related to the atomic initial kinematics. According to the Einstein equivalence principle, we develop a method to calculate this coupling effect in a space-stretching free-falling frame, based on which an improved frequency-shift gravity-gradient compensation technique is put forward to make high-accuracy weak-equivalence-principle tests with the microscopic particles, such as at the level of ${10}^{\ensuremath{-}14}$, more possible.

Physical Review A•Nov 5, 2018•8 citations

Mapping the absolute magnetic field and evaluating the quadratic Zeeman-effect-induced systematic error in an atom interferometer gravimeter

Qingqing Hu, Christian Freier, Bastian Leykauf +4 more

Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the $\ensuremath{\mu}\mathrm{Gal}$ regime ($1\ensuremath{\mu}\mathrm{Gal}={10}^{\ensuremath{-}8}\mathrm{m}/{\mathrm{s}}^{2}\ensuremath{\approx}{10}^{\ensuremath{-}9}\mathrm{g}$). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the gravimetric atom interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step-size-dependent magnetic field measurement uncertainty, present vector light shift and tensor light shift induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman-effect-induced gravity measurement error in GAIN as $2.04\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Gal}$. The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman-effect-induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.

arXiv:1805.05159•Physical Review A•Sep 20, 2017•38 citations

Dependence of sensitivity of atom interferometer gravimeters on the Raman laser pulse sequences

Ren Li-Chun, Zhou Lin, Runbing Li +4 more

We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.

Acta Physica Sinica•Jan 1, 2009•4 citations

Effects of pulse durations in atom interferometry with double Raman diffraction

Nadja Augst, Albert Roura

Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.

arXiv:2611.12586•Nov 9, 2026•0 citations

Improved frequency shift compensation technique and pulse sequence for multi-loop atom interference experiments

Ya-Jie Wang, Xiaoyu Lu, Jiao Zhang +6 more

Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.

Physica Scripta•Aug 19, 2024•1 citation
The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10 −10 g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.
For high-precision atom interferometry gravimeters, the effect of the Raman pulse duration will become an appreciable fraction and need to be taken into account. Its influence has been reported considering a homogeneous Earth’s gravitational field in some previous works. In this paper, by decomposing the time evolution operator into two parts, the free evolution part and the interaction part, we develop an approach to study this effect in a realistic situation where the Earth’s gravitational field is inhomogeneous. A mathematic expression for the interferometer phase shift because of the Raman pulse duration effect is obtained, which shows that the Raman pulse duration should be taken into account when the gravimeter reaches an accuracy of 10−10 g.
Although frequency-shift gravity-gradient compensation is currently the technique with the most potential to test the weak equivalence principle with atom interferometry at high precision, it faces an unavoidable obstacle on how to cancel the coupling between the Raman-pulse-duration effect and the gravity gradient related to the atomic initial kinematics. According to the Einstein equivalence principle, we develop a method to calculate this coupling effect in a space-stretching free-falling frame, based on which an improved frequency-shift gravity-gradient compensation technique is put forward to make high-accuracy weak-equivalence-principle tests with the microscopic particles, such as at the level of ${10}^{\ensuremath{-}14}$, more possible.
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the $\ensuremath{\mu}\mathrm{Gal}$ regime ($1\ensuremath{\mu}\mathrm{Gal}={10}^{\ensuremath{-}8}\mathrm{m}/{\mathrm{s}}^{2}\ensuremath{\approx}{10}^{\ensuremath{-}9}\mathrm{g}$). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the gravimetric atom interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step-size-dependent magnetic field measurement uncertainty, present vector light shift and tensor light shift induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman-effect-induced gravity measurement error in GAIN as $2.04\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Gal}$. The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman-effect-induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.
We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.
Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.
Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.