Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Raman pulse duration effect in high-precision atom interferometry gravimeters

Li Xia, Cheng-Gang Shao, Zhong-Kun Hu

Published Jan 12, 2015• 20 citations
Publisher

Abstract

For high-precision atom interferometry gravimeters, the effect of the Raman pulse duration will become an appreciable fraction and need to be taken into account. Its influence has been reported considering a homogeneous Earth’s gravitational field in some previous works. In this paper, by decomposing the time evolution operator into two parts, the free evolution part and the interaction part, we develop an approach to study this effect in a realistic situation where the Earth’s gravitational field is inhomogeneous. A mathematic expression for the interferometer phase shift because of the Raman pulse duration effect is obtained, which shows that the Raman pulse duration should be taken into account when the gravimeter reaches an accuracy of 10−10 g.

DOI
10.1364/josab.32.000248

Related papers

Effect of Raman-pulse duration related to the magnetic field gradient in high-precision atom gravimeters

Yuan Sheng Cheng, Yu-Jie Tan, Min-Kang Zhou +3 more

The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10 −10 g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.

Chinese Physics B•Mar 1, 2018•4 citations

Raman-pulse-duration effect in gravity gradiometers composed of two atom interferometers

Cheng-Gang Shao, Dekai Mao, Min-Kang Zhou +4 more

We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.

arXiv:1503.01199•Physical Review A•Nov 16, 2015•7 citations

Analytical framework for dynamic light pulse atom interferometry at short interrogation times

Richard E. Stoner, David L. Butts, Joseph M. Kinast +1 more

High-precision inertial sensing demonstrations with light pulse atom interferometry have typically used Raman pulses having durations orders of magnitude shorter than the dwell time between interferometer pulses. Environmentally robust sensors operating at high-bandwidth will be required to operate at short (millisecond scale) dwell times between Raman pulses. In such an operational mode, the Raman pulse duration becomes an appreciable fraction of the dwell time between pulses. In addition, high-precision inertial sensing applications have typically been demonstrated in mildly dynamic or nondynamic environments having low rate of change of inertial input, ensuring that applied Raman pulses satisfy the Raman resonance condition. Application of nonresonant pulses will be inevitable in sensors registering time-varying inertial input. We present a diagrammatic technique for calculation of atomic output state populations for multipulse atom optics manipulations that explicitly account for the effects of finite pulse duration and finite Raman detuning effects on the laser-induced atomic phase. We analyze several atom interferometer sequences. We report accelerometer and gyroscope phase evolution for fixed Raman laser frequency difference incorporating corrections in powers of the ratio of pulse duration to time interval between interferometer pulses. Our accelerometer result agrees with other published results.

Journal of the Optical Society of America B•Sep 13, 2011•29 citations

Improved frequency shift compensation technique and pulse sequence for multi-loop atom interference experiments

Ya-Jie Wang, Xiaoyu Lu, Jiao Zhang +6 more

Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.

Physica Scripta•Aug 19, 2024•1 citation

Effects of pulse durations in atom interferometry with double Raman diffraction

Nadja Augst, Albert Roura

Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.

arXiv:2611.12586•Nov 9, 2026•0 citations

Dependence of sensitivity of atom interferometer gravimeters on the Raman laser pulse sequences

Ren Li-Chun, Zhou Lin, Runbing Li +4 more

We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.

Acta Physica Sinica•Jan 1, 2009•4 citations
For high-precision atom interferometry gravimeters, the effect of the Raman pulse duration will become an appreciable fraction and need to be taken into account. Its influence has been reported considering a homogeneous Earth’s gravitational field in some previous works. In this paper, by decomposing the time evolution operator into two parts, the free evolution part and the interaction part, we develop an approach to study this effect in a realistic situation where the Earth’s gravitational field is inhomogeneous. A mathematic expression for the interferometer phase shift because of the Raman pulse duration effect is obtained, which shows that the Raman pulse duration should be taken into account when the gravimeter reaches an accuracy of 10−10 g.
The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10 −10 g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.
We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.
High-precision inertial sensing demonstrations with light pulse atom interferometry have typically used Raman pulses having durations orders of magnitude shorter than the dwell time between interferometer pulses. Environmentally robust sensors operating at high-bandwidth will be required to operate at short (millisecond scale) dwell times between Raman pulses. In such an operational mode, the Raman pulse duration becomes an appreciable fraction of the dwell time between pulses. In addition, high-precision inertial sensing applications have typically been demonstrated in mildly dynamic or nondynamic environments having low rate of change of inertial input, ensuring that applied Raman pulses satisfy the Raman resonance condition. Application of nonresonant pulses will be inevitable in sensors registering time-varying inertial input. We present a diagrammatic technique for calculation of atomic output state populations for multipulse atom optics manipulations that explicitly account for the effects of finite pulse duration and finite Raman detuning effects on the laser-induced atomic phase. We analyze several atom interferometer sequences. We report accelerometer and gyroscope phase evolution for fixed Raman laser frequency difference incorporating corrections in powers of the ratio of pulse duration to time interval between interferometer pulses. Our accelerometer result agrees with other published results.
Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.
Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.
We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.