Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE International Superconductive Electronics Conference (ISEC)

Readout Electronics for the Kinetic Inductance Detectors of CALDER

Lorenzo Minutolo, Fabio Bellini, L. Cardani, N. Casali, C. Cosmelli, Angelo Cruciani, M. Martínez, S. Di Domizio, M. G. Castellano, I. Colantoni, Antonio D’Addabbo, C. Tomei, M. Vignati

Published Jun 1, 2017• 0 citations
Publisher

Abstract

When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs,causing sizable variations in the kinetic inductance and, thus, the response of the LC circuit. This concept is at the basis of Kinetic Inductance Detectors (KIDs). The CALDER project aims to develope high sensitivity, cryogenic light detectors using KIDs in combination with a silicon absorber to cover, via phonon mediation, an area of several cm2 [1]. This contribution focuses on the development of a low-noise, digital and analogical,electronics for the sensor's readout and on the design and testing of a new geometry for the superconductive resonator to improve detector sensitivity.

DOI
10.1109/isec.2017.8314229

Related papers

Multiplexable kinetic inductance detectors

Ben Mazin, Peter K. Day, Jonas Stasys Zmuidzinas +1 more

We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors.This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution.The readout is based on the fact that the kinetic surface inductance L s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T c .An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit.By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 //m 3 .As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor.However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~ 10 3 detectors with a single HEMT amplifier. DETECTOR CONCEPTKinetic inductance detectors operate on the principle that a change in the number of quasiparticles in a superconductor will produce a change in the kinetic inductance.This occurs because the quasiparticles block Cooper pairs from occupying some of the electron states.Photons (or particles) are absorbed in the superconductor, producing quasiparticles, and the resulting change in the inductance is measured to produce the detector output.Bolometric detectors using kinetic inductance thermometers have been previously suggested [1, 2, 3, 4, 5, 6].However, such thermometers must be operated close to T c , since the variation of the kinetic inductance with temperature is most rapid near T c , and vanishes exponentially at low temperatures.Although it has been discussed previously [7], it is not widely appreciated that the the variation of the kinetic inductance with energy or quasiparticle number is actually fairly constant down to very low temperatures.The idea, then, is to use the kinetic inductance effect to read out changes in the quasiparticle population produced by the direct absorbtion of pair-breaking photons rather than changes in the temperature of the phonons in a bolometric absorber.How can one measure the change in the kinetic inductance of a superconductor?One way is to make the superconductor act as an inductive element in a resonant circuit.A change in the quasiparticle population will change the inductance of the superconductor, and therefore the resonance frequency of the circuit, which can be monitored by measuring the transmission phase of a constant-frequency microwave probe signal transmitted through (or reflected from) the resonator.This method is extremely attractive, due both to CP605, Low Temperature Detectors, edited by F. S. Porter et al.

AIP conference proceedings•Jan 1, 2002•48 citations

Performance of a KID: On the influence of the resonator geometry on the noise and Q-factor of a kinetic inductance detector

Kee Scholten

Space-based astronomy is in need of a photon-noise limited detector with multiplexing opportunities. The kinetic inductance detector (KID) is capable of both properties. An incoming photon breaks Cooper pairs in the superconducting layer of the KID, which leads to a change in inductance, which can be detected with phase- and amplitude read-out. Photon noise, generation-recombination noise are inevitable noise sources, but two-level system noise can be minimized by adjusting the resonator and its geometry. To gain insight in the noise and loss sources this thesis investigates the difference between microstrip and co-planar waveguide resonators; and the difference between a silicon substrate and a silicon-on-insulator substrate. Numerical analysis shows that: noise in all types of resonators are dielectric bulk dominated; an Al superconducting layer shows has different losses in terms of Q-factor, compared to a NbTiN superconducting layer, but quantitatively the same internal Q-factor in the order of 105 is achieved; an Al superconducting layer in a microstrip has 5dBc/Hz and 2dBc/Hz higher noise in the metal-air and metal-edge interfaces, respectively, compared to a NbTiN superconducting layer; an Al on Si CPW and microstrip have the same Q-factor performance; an Al on Si CPW has a 2-8dBc/Hz more noise at all interfaces compared to an Al on Si microstrip; a buried oxide layer has no influence on the loss in terms of the Q-factor for 100nm Al on Si substrate CPWs; and that the noise of an Al on SOI CPW is bulk dominated, and the dielectric bulk contributes 10dBc/Hz more to the noise, compared to an Al on Si CPW. Experimental analysis shows that a gapwidth of wgap ? 10?m for Al on SOI CPWs shows no response, due to high two-level system noise. Low Q-factors in the order of 104 have been measured for Al on SOI CPWs, which is low compared to literature. A high set-up noise of -85dBc/Hz and divergent relationships with the internal power indicate that TLS-noise does not dominate the measurements, and set-up negatively influences the measurements. In conclusion, the resonator geometry is an important factor for the performance of a KID in terms of noise and Q-factors. A buried oxide layer has no consequence for the Q-factor, and negatively affects the noise of a CPW.

•Sep 24, 2015•0 citations

Development of an Array of Kinetic Inductance Magnetometers (KIMs)

Sasha Sypkens, Farzad Faramarzi, Marco Colangelo +6 more

We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).

arXiv:2102.11001•IEEE Transactions on Applied Superconductivity•Feb 3, 2021•3 citations

A Lumped Element Kinetic Inductance device for detection of THz radiation

Simon M. Doyle, Philip D. Mauskopf, C. Dunscombe +2 more

Kinetic inductance detectors (KIDs) provide a promising solution to the problem of producing large format arrays of ultra sensitive detectors for astronomy. Traditionally KIDs have been constructed from superconducting quarter-wavelength or half-wavelength resonator elements capacitively coupled to a co-planar feed line. Photons are detected by measuring the change in quasi-particle density caused by the splitting of Cooper pairs in the superconducting resonant element. This change in quasi-particle density alters the kinetic inductance, and hence the resonant frequency of the resonant element. This arrangement requires the quasi-particles generated by photon absorption to be concentrated at positions of high current density in the resonator. This is usually achieved through antenna coupling or quasi-particle trapping. For these detectors to work at wavelengths shorter than around 500 mum where antenna coupling can introduce a significant loss of efficiency, then a direct absorption method needs to be considered [3]. One solution to this problem is the Lumped Element KID (LEKID), which shows no current variation along its length and can be arranged into a photon absorbing area coupled to free space and therefore requiring no antennas or quasi-particle trapping. This paper outlines the basic concept of the LEKID, along with theoretical performance and experimental data for these devices.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2007•6 citations

Ultrasensitive hot-electron kinetic-inductance detectors

A. Sergeev, Boris S. Karasik, I. G. Gogidze +1 more

While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.

AIP conference proceedings•Jan 1, 2002•3 citations

Non-Equilibrium Superconductivity in Kinetic Inductance Detectors for THz Photon Sensing

D. J. Goldie, S. Withington

Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed

arXiv:1401.2291•Jan 10, 2014•1 citation
When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs,causing sizable variations in the kinetic inductance and, thus, the response of the LC circuit. This concept is at the basis of Kinetic Inductance Detectors (KIDs). The CALDER project aims to develope high sensitivity, cryogenic light detectors using KIDs in combination with a silicon absorber to cover, via phonon mediation, an area of several cm2 [1]. This contribution focuses on the development of a low-noise, digital and analogical,electronics for the sensor's readout and on the design and testing of a new geometry for the superconductive resonator to improve detector sensitivity.
We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors.This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution.The readout is based on the fact that the kinetic surface inductance L s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T c .An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit.By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 //m 3 .As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor.However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~ 10 3 detectors with a single HEMT amplifier. DETECTOR CONCEPTKinetic inductance detectors operate on the principle that a change in the number of quasiparticles in a superconductor will produce a change in the kinetic inductance.This occurs because the quasiparticles block Cooper pairs from occupying some of the electron states.Photons (or particles) are absorbed in the superconductor, producing quasiparticles, and the resulting change in the inductance is measured to produce the detector output.Bolometric detectors using kinetic inductance thermometers have been previously suggested [1, 2, 3, 4, 5, 6].However, such thermometers must be operated close to T c , since the variation of the kinetic inductance with temperature is most rapid near T c , and vanishes exponentially at low temperatures.Although it has been discussed previously [7], it is not widely appreciated that the the variation of the kinetic inductance with energy or quasiparticle number is actually fairly constant down to very low temperatures.The idea, then, is to use the kinetic inductance effect to read out changes in the quasiparticle population produced by the direct absorbtion of pair-breaking photons rather than changes in the temperature of the phonons in a bolometric absorber.How can one measure the change in the kinetic inductance of a superconductor?One way is to make the superconductor act as an inductive element in a resonant circuit.A change in the quasiparticle population will change the inductance of the superconductor, and therefore the resonance frequency of the circuit, which can be monitored by measuring the transmission phase of a constant-frequency microwave probe signal transmitted through (or reflected from) the resonator.This method is extremely attractive, due both to CP605, Low Temperature Detectors, edited by F. S. Porter et al.
Space-based astronomy is in need of a photon-noise limited detector with multiplexing opportunities. The kinetic inductance detector (KID) is capable of both properties. An incoming photon breaks Cooper pairs in the superconducting layer of the KID, which leads to a change in inductance, which can be detected with phase- and amplitude read-out. Photon noise, generation-recombination noise are inevitable noise sources, but two-level system noise can be minimized by adjusting the resonator and its geometry. To gain insight in the noise and loss sources this thesis investigates the difference between microstrip and co-planar waveguide resonators; and the difference between a silicon substrate and a silicon-on-insulator substrate. Numerical analysis shows that: noise in all types of resonators are dielectric bulk dominated; an Al superconducting layer shows has different losses in terms of Q-factor, compared to a NbTiN superconducting layer, but quantitatively the same internal Q-factor in the order of 105 is achieved; an Al superconducting layer in a microstrip has 5dBc/Hz and 2dBc/Hz higher noise in the metal-air and metal-edge interfaces, respectively, compared to a NbTiN superconducting layer; an Al on Si CPW and microstrip have the same Q-factor performance; an Al on Si CPW has a 2-8dBc/Hz more noise at all interfaces compared to an Al on Si microstrip; a buried oxide layer has no influence on the loss in terms of the Q-factor for 100nm Al on Si substrate CPWs; and that the noise of an Al on SOI CPW is bulk dominated, and the dielectric bulk contributes 10dBc/Hz more to the noise, compared to an Al on Si CPW. Experimental analysis shows that a gapwidth of wgap ? 10?m for Al on SOI CPWs shows no response, due to high two-level system noise. Low Q-factors in the order of 104 have been measured for Al on SOI CPWs, which is low compared to literature. A high set-up noise of -85dBc/Hz and divergent relationships with the internal power indicate that TLS-noise does not dominate the measurements, and set-up negatively influences the measurements. In conclusion, the resonator geometry is an important factor for the performance of a KID in terms of noise and Q-factors. A buried oxide layer has no consequence for the Q-factor, and negatively affects the noise of a CPW.
We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).
Kinetic inductance detectors (KIDs) provide a promising solution to the problem of producing large format arrays of ultra sensitive detectors for astronomy. Traditionally KIDs have been constructed from superconducting quarter-wavelength or half-wavelength resonator elements capacitively coupled to a co-planar feed line. Photons are detected by measuring the change in quasi-particle density caused by the splitting of Cooper pairs in the superconducting resonant element. This change in quasi-particle density alters the kinetic inductance, and hence the resonant frequency of the resonant element. This arrangement requires the quasi-particles generated by photon absorption to be concentrated at positions of high current density in the resonator. This is usually achieved through antenna coupling or quasi-particle trapping. For these detectors to work at wavelengths shorter than around 500 mum where antenna coupling can introduce a significant loss of efficiency, then a direct absorption method needs to be considered [3]. One solution to this problem is the Lumped Element KID (LEKID), which shows no current variation along its length and can be arranged into a photon absorbing area coupled to free space and therefore requiring no antennas or quasi-particle trapping. This paper outlines the basic concept of the LEKID, along with theoretical performance and experimental data for these devices.
While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.
Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed