Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed
Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed
Low temperature microwave superconducting resonators (SRs) are attractive candidates for producing quantum-sensitive, arrayable energy or power detectors for astrophysical and other precision measurement applications. Their readout uses a microwave probe signal with quanta of energy well below the threshold for pair-breaking in the superconductor. We have calculated the non-equilibrium quasiparticle and phonon distributions generated by the photons of the probe signal of a resonator operating well below its superconducting transition temperature T c as the absorbed probe power was changed using the coupled kinetic equations described by Chang and Scalapino. The calculations give insight into a rate equation estimate which suggests that the quasiparticle distributions can be driven far from their thermal equilibrium value for typical readout powers. From the driven quasiparticle distribution functions, the driven quasiparticle number densities and lifetimes were calculated. An effective temperature to describe the driven quasiparticles was defined. The non-equilibrium lifetimes were compared to the distribution-averaged thermal lifetimes at the effective temperature and good agreement was found typically within a few per cent. We used the non-equilibrium quasiparticle distribution to model a representative SR. The complex conductivity and hence the frequency dependence of the experimentally measured forward scattering parameter S 21 of the SR as a function of absorbed power were found. The non-equilibrium S 21 cannot be accurately modeled by a thermal distribution even at its own elevated temperature, having a higher quality factor in all cases studied, although for low absorbed powers the two effective temperatures are similar. From the non-equilibrium lifetimes and number densities we determined the achievable noise equivalent power (NEP) of the resonator used as a power detector as a function of absorbed microwave power. Simpler expressions to evaluate the effective quasiparticle temperature as a function of absorbed power have also been derived. We conclude that multiple photon absorption from the microwave probe increases the quasiparticle number above the thermal background and ultimately limits the achievable NEP of the resonator at temperatures well below T c .
The response of superconducting pair-breaking detectors is dependent on the details of the quasiparticle distribution. In Kinetic Inductance Detectors (KIDs), where both pair breaking and non-pair breaking photons are absorbed simultaneously, calculating the detector response therefore requires knowledge of the often nonequilibrium distributions. The quasiparticle effective temperature provides a good approximation to these nonequilibrium distributions. We compare an analytical expression relating absorbed power and the quasiparticle effective temperature in superconducting thin films to full solutions for the nonequilibrium distributions, and find good agreement for a range of materials, absorbed powers, photon frequencies and temperatures typical of KIDs. This analytical expression allows inclusion of nonequilibrium effects in device models without solving for the detailed distributions. We also show our calculations of the frequency dependence of the detector response are in agreement with recent experimental measurements of the response of Ta KIDs at THz frequencies.
Abstract The Cooper-pair breaking efficiency quantifies the effectiveness with which incident energy, such as that delivered by photons or phonons, is converted into quasiparticles—a process central to the response of superconducting pair-breaking detectors. We measure the pair-breaking efficiency in two far-infrared kinetic inductance detectors (KIDs) operating at 4.3 THz and 15 THz by comparing photon noise and thermal generation-recombination noise. Both KIDs are lumped-element devices consisting of a tantalum interdigitated capacitor in parallel with an aluminum inductor meandered line, which also acts as a low-volume absorber. The measured pair-breaking efficiencies are 0.42 and 0.07 for the 4.3 THz and 15 THz devices, respectively. The extremely low efficiency at 15 THz, a frequency well above the aluminum Debye frequency, is mainly attributed to rapid anharmonic decay of phonons, with additional phonon relaxation in the tantalum layer further reducing the available phonon population for pair-breaking. Furthermore, a relationship between the pair-breaking efficiency and detector resolving power is derived.
While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.
We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors.This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution.The readout is based on the fact that the kinetic surface inductance L s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T c .An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit.By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 //m 3 .As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor.However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~ 10 3 detectors with a single HEMT amplifier. DETECTOR CONCEPTKinetic inductance detectors operate on the principle that a change in the number of quasiparticles in a superconductor will produce a change in the kinetic inductance.This occurs because the quasiparticles block Cooper pairs from occupying some of the electron states.Photons (or particles) are absorbed in the superconductor, producing quasiparticles, and the resulting change in the inductance is measured to produce the detector output.Bolometric detectors using kinetic inductance thermometers have been previously suggested [1, 2, 3, 4, 5, 6].However, such thermometers must be operated close to T c , since the variation of the kinetic inductance with temperature is most rapid near T c , and vanishes exponentially at low temperatures.Although it has been discussed previously [7], it is not widely appreciated that the the variation of the kinetic inductance with energy or quasiparticle number is actually fairly constant down to very low temperatures.The idea, then, is to use the kinetic inductance effect to read out changes in the quasiparticle population produced by the direct absorbtion of pair-breaking photons rather than changes in the temperature of the phonons in a bolometric absorber.How can one measure the change in the kinetic inductance of a superconductor?One way is to make the superconductor act as an inductive element in a resonant circuit.A change in the quasiparticle population will change the inductance of the superconductor, and therefore the resonance frequency of the circuit, which can be monitored by measuring the transmission phase of a constant-frequency microwave probe signal transmitted through (or reflected from) the resonator.This method is extremely attractive, due both to CP605, Low Temperature Detectors, edited by F. S. Porter et al.
Thin-film superconductors with thickness ∼30–500 nm are used as non-equilibrium quantum detectors for photons, phonons or more exotic particles. One of the most basic questions in determining their limiting sensitivity is the efficiency with which the quanta of interest couple to the detected quasiparticles. As low temperature superconducting resonators, thin films are attractive candidates for producing quantum-sensitive arrayable sensors and the readout uses an additional microwave probe. We have calculated the quasiparticle generation efficiency η s for low energy photons in a representative, clean thin-film superconductor (Al) operating well below its superconducting transition temperature as a function of film thickness, within the framework of the coupled kinetic equations described by Chang and Scalapino (1978 J. Low Temp. Phys. 31 1–32). We have also included the effect of a lower frequency probe. We show that phonon loss from the thin film reduces η s by as much as 40% compared to earlier models that considered relatively thick films or infinite volumes. We also show that the presence of the probe and signal enhances the generation efficiency slightly. We conclude that the ultimate limiting noise equivalent power of this class of detector is determined by the thin-film geometry.