Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SCALAR MULTI-PASS ATOMIC MAGNETOMETER

Michael V. Romalis, Thomas W. Kornack

Published Aug 1, 2017• 0 citations
OpenAlex

Abstract

Abstract : We investigated the feasibility of a femto-Tesla level scalar atomic magnetometer operating in Earths field. Our approach is unique in using multi-pass alkali-metal cells, quantum-non-demolition measurements, and suppression of spin-exchange relaxation to achieve the highest sensitivity per unit volume. We developed a new multi-pass cell geometry with a small internal volume and experimentally verified the predictions of our model for quantum spin noise. We also investigated the availability of pulsed pump and probe lasers to operate a high-sensitivity atomic magnetometer.

Related papers

Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells

D. Sheng, Lun Li, Nezih Dural +1 more

Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multipass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize a magnetic field sensitivity of 0.54 fT/Hz(1/2), which improves by an order of magnitude the best scalar magnetometer sensitivity and exceeds, for example, the quantum limit set by the spin-exchange collisions for a scalar magnetometer with the same measurement volume operating in a continuous regime.

arXiv:1208.1099•Physical Review Letters•Apr 18, 2013•373 citations

High-sensitivity multi-channel atomic magnetometer

Young Jin Kim

High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.

•Jan 23, 2023•0 citations

Signal-enhanced high-sensitivity atomic magnetometer based on multi-pass cell

Jin Peng, Yiran Yin, An‐Ning Xu +3 more

Abstract We propose a signal- and sensitivity-enhanced spin-exchange-relaxation-free atomic magnetometer utilizing a multi-pass cell with a highly spatially homogeneous optical pumping scheme. The relationship between the magnetometer’s performance and the number of probe beam passes is measured. The optical rotation angle exhibits a linear correlation with the number of passes, achieving 89 mrad nT−1 for a quadruple-pass cell. However, the sensitivity does not increase linearly when further increasing the optical length due to the noise limit. This work provides a method to study the enhancement performance of the magnetic response and sensitivity in atomic magnetometers by using multi-pass cells.

Applied Physics Express•Nov 1, 2024•3 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•18 citations

Low-noise high-density alkali-metal scalar magnetometer

Sylvia Smullin, Igor Savukov, Georgios Vasilakis +2 more

We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about $1.5\text{ }{\text{cm}}^{3}$. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.

arXiv:physics/0611085•Physical Review A•Sep 29, 2009•142 citations

Ultra-sensitive atomic magnetometers and their applications

M. V. Romalis

In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.

IEEE International Magnetics Conference•May 1, 2006•0 citations
Abstract : We investigated the feasibility of a femto-Tesla level scalar atomic magnetometer operating in Earths field. Our approach is unique in using multi-pass alkali-metal cells, quantum-non-demolition measurements, and suppression of spin-exchange relaxation to achieve the highest sensitivity per unit volume. We developed a new multi-pass cell geometry with a small internal volume and experimentally verified the predictions of our model for quantum spin noise. We also investigated the availability of pulsed pump and probe lasers to operate a high-sensitivity atomic magnetometer.
Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multipass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize a magnetic field sensitivity of 0.54 fT/Hz(1/2), which improves by an order of magnitude the best scalar magnetometer sensitivity and exceeds, for example, the quantum limit set by the spin-exchange collisions for a scalar magnetometer with the same measurement volume operating in a continuous regime.
High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.
Abstract We propose a signal- and sensitivity-enhanced spin-exchange-relaxation-free atomic magnetometer utilizing a multi-pass cell with a highly spatially homogeneous optical pumping scheme. The relationship between the magnetometer’s performance and the number of probe beam passes is measured. The optical rotation angle exhibits a linear correlation with the number of passes, achieving 89 mrad nT−1 for a quadruple-pass cell. However, the sensitivity does not increase linearly when further increasing the optical length due to the noise limit. This work provides a method to study the enhancement performance of the magnetic response and sensitivity in atomic magnetometers by using multi-pass cells.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about 1.5 cm31.5\text{ }{\text{cm}}^{3}1.5 cm3. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.
In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.