IEEE International Magnetics Conference

Ultra-sensitive atomic magnetometers and their applications

M. V. Romalis

Published May 1, 2006• 0 citations
Publisher

Abstract

In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.

DOI
10.1109/intmag.2006.376111

Related papers

High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation

J. C. Allred, ROBERT LYMAN, Thomas W. Kornack +1 more

Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sensitivity of $10\text{ }\mathrm{f}\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$, limited by magnetic noise produced by Johnson currents in the magnetic shields. We extend a previous theoretical analysis of spin exchange in low magnetic fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer to be $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}\text{ }\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$.

Physical Review Letters•Sep 9, 2002•1,078 citations

Magnetic-field-independent spin-exchange relaxation-free magnetometer

Mark Dikopoltsev, Uriel Levy, Or Katz

Spin-exchange relaxation-free magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the microgauss to milligauss range. At geomagnetic fields however, these sensors quickly lose their magnetic sensitivity due to spin decoherence by random spin-exchange collisions. Here we discover that atoms with nuclear spin $I=\frac{1}{2}$ can operate in the spin-exchange relaxation-free regime even at high magnetic field. We counterintuitively show that frequent collisions between a dense and optically inaccessible $(I=\frac{1}{2})$ gas with another optically accessible spin gas ($I>\frac{1}{2}$) improve the fundamental magnetic sensitivity of the latter. We analyze the performance of a dual-species potassium and atomic hydrogen magnetometer and project a fundamental sensitivity of about $10\phantom{\rule{0.28em}{0ex}}\mathrm{aT}\phantom{\rule{0.16em}{0ex}}{({\mathrm{cm}}^{3}\text{/}\mathrm{Hz})}^{1/2}$ at geomagnetic fields for feasible experimental conditions.

arXiv:2209.13086•Physical Review A•Mar 3, 2025•9 citations

Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

IEEE Transactions on Magnetics•Oct 1, 2011•53 citations

The influence of spin-destruction collisions on the precision of atomic SERF magnetometer

Lijun Liu, Shuming Cheng, Zairong Xi +1 more

High precision measurement of magnetic fields has been of great importance for both fundamental physics and practical applications. Magnetometers based on atomic spin effect provide a new technique for high precision measurement and have been enabled as the most sensitive magnetic sensors at present. However, the atomic spins used as probes to sense the magnetic fields are prone to the decoherence effects. For the atomic spin-exchange relaxation free (SERF) magnetometer which operates with high alkali atoms density in very low magnetic fields, the main relaxation mechanism is the spin-destruction collisions between atoms. In this paper, it is demonstrated by numerical simulations that the precision of the atomic SERF magnetometer is significantly affected by this spin-destruction collisions.

Chinese Control Conference (CCC)•Jul 1, 2014•0 citations

Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields

Igor Savukov, Scott J. Seltzer, Michael V. Romalis +1 more

We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.

Physical Review Letters•Aug 3, 2005•315 citations

A fast determination method for identifying the spin exchange relaxation free regime of atomic magnetometer

Yanzhang Wang, Xue Zhang, Jianan Qin +1 more

Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 1, 2016•1 citation
In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.
Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sensitivity of $10\text{ }\mathrm{f}\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$, limited by magnetic noise produced by Johnson currents in the magnetic shields. We extend a previous theoretical analysis of spin exchange in low magnetic fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer to be $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}\text{ }\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$.
Spin-exchange relaxation-free magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the microgauss to milligauss range. At geomagnetic fields however, these sensors quickly lose their magnetic sensitivity due to spin decoherence by random spin-exchange collisions. Here we discover that atoms with nuclear spin I=12I=\frac{1}{2}I=21​ can operate in the spin-exchange relaxation-free regime even at high magnetic field. We counterintuitively show that frequent collisions between a dense and optically inaccessible (I=12)(I=\frac{1}{2})(I=21​) gas with another optically accessible spin gas (I>12I>\frac{1}{2}I>21​) improve the fundamental magnetic sensitivity of the latter. We analyze the performance of a dual-species potassium and atomic hydrogen magnetometer and project a fundamental sensitivity of about 10aT(cm3/Hz)1/210\phantom{\rule{0.28em}{0ex}}\mathrm{aT}\phantom{\rule{0.16em}{0ex}}{({\mathrm{cm}}^{3}\text{/}\mathrm{Hz})}^{1/2}10aT(cm3/Hz)1/2 at geomagnetic fields for feasible experimental conditions.
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.
High precision measurement of magnetic fields has been of great importance for both fundamental physics and practical applications. Magnetometers based on atomic spin effect provide a new technique for high precision measurement and have been enabled as the most sensitive magnetic sensors at present. However, the atomic spins used as probes to sense the magnetic fields are prone to the decoherence effects. For the atomic spin-exchange relaxation free (SERF) magnetometer which operates with high alkali atoms density in very low magnetic fields, the main relaxation mechanism is the spin-destruction collisions between atoms. In this paper, it is demonstrated by numerical simulations that the precision of the atomic SERF magnetometer is significantly affected by this spin-destruction collisions.
We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.
Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.