Advanced SQUID readout of cryogenic detectors

T. A. Girard, Jakob Flokstra, M. Podt, Maria Ribeiro Gomes, J. Weenink, Pavol Valko

Published Jun 5, 2001• 0 citations
OpenAlex

Related papers

Superconducting Quantum Interference devices and readout of cryogenic particle detectors

A.W. Hamster, Michiel J. van Duuren, Jakob Flokstra +1 more

•Nov 15, 1998•0 citations

Microwave SQUID for low-temperature detector readout

Fuminori Hirayama

The Japan Society of Applied Physics•Feb 13, 2013•0 citations

Microwave SQUID multiplexer for low-temperature detector readout

Fuminori Hirayama, Satoshi Kohjiro, Daiji Fukuda +5 more

IEICE Technical Report; IEICE Tech. Rep.•Oct 18, 2012•0 citations

Multiplexed Readout of MMC Detector Arrays Using Non-hysteretic rf-SQUIDs

Sebastian Kempf, Mathias Wegner, L. Gastaldo +2 more

arXiv:1309.4929•Journal of Low Temperature Physics•Dec 30, 2013•25 citations

Progress towards a double flux-locked-loop scheme for SQuID readout of TES detector arrays

G. Torrioli, Simona Lombardo, C. Macculi +2 more

Frequency Division Multiplexing technique for reading TES detectors with SQuID devices, requires high loop-gain up to MHz frequency range in the SQuID feedback loop. Such a requirement is difficult to achieve when the feedback loop has a physical length that makes the propagation times of signals not negligible, as in the case in which the readout electronics is placed at room temperature. A novel SQuID readout scheme, called Double Loop-Flux Locked loop (DLFLL), has been proposed earlier. According to this scheme it is possible to make use of a simplified cryogenic electronics, AC coupled, featuring low power dissipation, in order to obtain a cryogenic feedback loop that results in reduced propagation times of signals. The DC and low frequency signals are managed by a standard FLL electronics working at room temperature. Here we present the progress of the integrated Double Loop system.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 24, 2014•0 citations

Simultaneous readout of 128 X-ray and gamma-ray transition-edge microcalorimeters using microwave SQUID multiplexing

John A. B. Mates, Daniel Becker, D. A. Bennett +10 more

The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the arrays into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES) microcalorimeters contain roughly 250 detectors and use time-division multiplexing with Superconducting Quantum Interference Devices (SQUIDs). The bandwidth limits of this technology constrain the number of sensors per amplifier chain, a quantity known as the multiplexing factor, to several 10s. With microwave SQUID multiplexing, we can expand the readout bandwidth and enable much larger multiplexing factors. While microwave SQUID multiplexing of TES microcalorimeters has been previously demonstrated with small numbers of detectors, we now present a fully scalable demonstration in which 128 TES detectors are read out on a single pair of coaxial cables.

Applied Physics Letters•Aug 7, 2017•106 citations
Frequency Division Multiplexing technique for reading TES detectors with SQuID devices, requires high loop-gain up to MHz frequency range in the SQuID feedback loop. Such a requirement is difficult to achieve when the feedback loop has a physical length that makes the propagation times of signals not negligible, as in the case in which the readout electronics is placed at room temperature. A novel SQuID readout scheme, called Double Loop-Flux Locked loop (DLFLL), has been proposed earlier. According to this scheme it is possible to make use of a simplified cryogenic electronics, AC coupled, featuring low power dissipation, in order to obtain a cryogenic feedback loop that results in reduced propagation times of signals. The DC and low frequency signals are managed by a standard FLL electronics working at room temperature. Here we present the progress of the integrated Double Loop system.
The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the arrays into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES) microcalorimeters contain roughly 250 detectors and use time-division multiplexing with Superconducting Quantum Interference Devices (SQUIDs). The bandwidth limits of this technology constrain the number of sensors per amplifier chain, a quantity known as the multiplexing factor, to several 10s. With microwave SQUID multiplexing, we can expand the readout bandwidth and enable much larger multiplexing factors. While microwave SQUID multiplexing of TES microcalorimeters has been previously demonstrated with small numbers of detectors, we now present a fully scalable demonstration in which 128 TES detectors are read out on a single pair of coaxial cables.