Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Compact atom interferometer using a single laser

Sheng‐wey Chiow, Nan Yu

Published Jul 1, 2017• 1 citation
Publisher

Abstract

A laser system for a light-pulse atom interferometer typically includes a number of laser sources for cooling and for atom optics to meet different frequency detuning requirements at different stages of a measurement sequence. The number of laser units required makes the achievable minimum size and power of the instrument challenging, especially for space applications. We demonstrate a compact cesium atom interferometer operated by only a single laser. This is achieved by dynamically changing the laser output frequency while maintaining spectroscopic reference to an atomic transition. We are able to generate cold atoms and obtain atom interferometer fringes all with the same laser.

DOI
10.1109/fcs.2017.8088988

Related papers

A compact laser system for a portable atom interferometry gravimeter

Qin Luo, Heng Zhang, Ke Zhang +4 more

A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.

Review of Scientific Instruments•Apr 1, 2019•44 citations

5 Transportable laser system for atom interferometry

Patrick Cheinet, Franck Pereira dos Santos, Dos Santos +4 more

We describe an optical bench in which we lock the relative frequencies or phases of a set of three lasers in order to use them in a cold atoms interferometry experiment. As a new feature, the same two lasers serve alternately to cool atoms and to realize the atomic interferometer. This requires a fast change of the optical frequencies over a few GHz. The number of required independent laser sources is then only 3, which enables the construction of the whole laser system on a single transportable optical bench. Recent results obtained with this optical setup are also presented. c © 2005 Optical Society of America OCIS codes: 140.3320, 120.3180, 140.3550, 120.3930. Within the last decades, atom interferometers have de-veloped into a highly competitive tool for precision measurements.1 Atomic fountains used as atomic clocks are the best realization of the time unit.2 Atom inter-ferometry also promises sensors to be highly sensitive to inertial forces.3–6 The use of stimulated Raman transi-tions to manipulate the atomic wave packet has proven to be an efficient way to obtain high accuracy devices.5, 6

•Oct 28, 2005•0 citations

A transportable cold atom inertial sensor for space applications

Rémi Geiger, Guillaume Stern, Patrick Cheinet +7 more

Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).

International Conference on Space Optics (ICSO)•Nov 20, 2017•3 citations

Development of compact cold-atom sensors for inertial navigation

Baptiste Battelier, B. Barrett, Lauriane Fouché +7 more

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.

arXiv:1605.02454•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•84 citations

A Portable, Compact Cold Atom Physics Package for Atom Interferometry

Michael J. Mazon, Gebriel H. Iyanu, He Wang

In this paper, we report the design, implementation and experimental results of a portable, compact cold Cs atom physics package for atom interferometer experiments. With the physics package, we trapped and deep-cooled Cs atoms to ultracold temperatures of <; 5 μK. The deep-cooling method used in this work is relatively simple and effective, with which we obtained controlled temperature adjustment between 5 and 80 μK. The portability of the physics package makes it suitable for implementing atom interferometry with various interrogation configurations and relative orientations. The system is also good for studies of compact cold atom frequency standards. With the Raman laser and light pulse manipulation system we developed in this work, this portable cold Cs atom physics package is being used for atom interferometer experiments in our laboratory.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•3 citations

A continuous cold atomic beam interferometer

Hongbo Xue, Yanying Feng, Shu Chen +4 more

We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.

arXiv:1402.3822•Journal of Applied Physics•Mar 2, 2015•39 citations
A laser system for a light-pulse atom interferometer typically includes a number of laser sources for cooling and for atom optics to meet different frequency detuning requirements at different stages of a measurement sequence. The number of laser units required makes the achievable minimum size and power of the instrument challenging, especially for space applications. We demonstrate a compact cesium atom interferometer operated by only a single laser. This is achieved by dynamically changing the laser output frequency while maintaining spectroscopic reference to an atomic transition. We are able to generate cold atoms and obtain atom interferometer fringes all with the same laser.
A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.
We describe an optical bench in which we lock the relative frequencies or phases of a set of three lasers in order to use them in a cold atoms interferometry experiment. As a new feature, the same two lasers serve alternately to cool atoms and to realize the atomic interferometer. This requires a fast change of the optical frequencies over a few GHz. The number of required independent laser sources is then only 3, which enables the construction of the whole laser system on a single transportable optical bench. Recent results obtained with this optical setup are also presented. c © 2005 Optical Society of America OCIS codes: 140.3320, 120.3180, 140.3550, 120.3930. Within the last decades, atom interferometers have de-veloped into a highly competitive tool for precision measurements.1 Atomic fountains used as atomic clocks are the best realization of the time unit.2 Atom inter-ferometry also promises sensors to be highly sensitive to inertial forces.3–6 The use of stimulated Raman transi-tions to manipulate the atomic wave packet has proven to be an efficient way to obtain high accuracy devices.5, 6
Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).
Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.
In this paper, we report the design, implementation and experimental results of a portable, compact cold Cs atom physics package for atom interferometer experiments. With the physics package, we trapped and deep-cooled Cs atoms to ultracold temperatures of <; 5 μK. The deep-cooling method used in this work is relatively simple and effective, with which we obtained controlled temperature adjustment between 5 and 80 μK. The portability of the physics package makes it suitable for implementing atom interferometry with various interrogation configurations and relative orientations. The system is also good for studies of compact cold atom frequency standards. With the Raman laser and light pulse manipulation system we developed in this work, this portable cold Cs atom physics package is being used for atom interferometer experiments in our laboratory.
We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.