Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Optimal pre- and post-selections of weak measurements for precision parameter estimation

Xiong Liu, Xiaodong Qiu, Linguo Xie, Lan E Luo, Zhaoxue Li, Zhiyou Zhang, Jinglei Du

Published May 28, 2017• 5 citations
Publisher

Abstract

Weak measurements, which offer a significant signal enhancement with pre- and post-selections, have proven to be powerful for precision metrology. However, the measured precision of the parameter of interest is always limited by the post-selection-induced probe loss, especially in the presence of technical noise. In this paper, we investigate the optimal pre- and post-selections of weak measurements for precision metrology in the presence of technical noise. While weak measurements apply more generally, we experimentally measure the spin splitting induced by the spin Hall effect of light (SHEL) to approach this issue. The highest measured precision of the spin splitting can be obtained with the post-selected state in the nonlinear intermediate regime. Surprisingly, the pre- and post-selections for the largest weak-value amplification are incapable of estimation of the spin splitting, since the amplified shift is independent of the spin splitting. Our results are not restricted to the SHEL and could be applied to other parameter estimations with weak measurements.

DOI
10.1063/1.4984264

Related papers

Weak values considered harmful

Christopher Ferrie, Joshua Combes

We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

•Jul 15, 2013•4 citations

Optimal preselection and postselection in weak measurements for observing photonic spin Hall effect

Xinxing Zhou, Xing Li, Hailu Luo +1 more

Photonic spin Hall effect (SHE) holds great potential applications in precision metrology. How to obtain a high measurement precision is an important issue to detect the photonic SHE. In this Letter, we propose using optimal preselection and postselection in weak measurements to enhance the measurement precision. We find that the maximum weak value and pointer shift can be obtained with an optimal overlap of preselection and postselection states. These findings offer the possibility for improving the precision of weak measurements and thereby have possible applications for accurately characterizing the parameters of nanostructures.

arXiv:1404.2721•Applied Physics Letters•Feb 3, 2014•51 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Precision metrology with weak measurements using spin splitting of light

Xiaodong Qiu, Linguo Xie, Jinglei Du +3 more

Since its first introduction over twenty years ago, weak measurements have gradually became an useful metrology tool in the laboratory. Due to its desirable amplification effect, a small physical variable can be detected with weak measurements. Spin splitting of light, which stems from the interaction between the spin and orbital angular momentum in optical reflection or refraction at the interface of mediums, is always a weak effect. However, the spin splitting of light can be detected easily with weak measurements. Remarkably, the spin splitting of light is sensitive to the physical parameter variations of system. Using the spin splitting as a probe, the physical parameter can be accurately estimated with weak measurements. Here, we review some of our works on precision metrology with weak measurements using the spin splitting of light as a probe, such as estimation of the magneto-optical constant of a magnetic film, determination of the focused beam waist, and measurement of the polarization state of light.

IEEE International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)•Jul 1, 2016•1 citation

Weak value amplification of Geometric Spin Hall shift of light beam

Sumit Goswami, Nirmalya Ghosh, Mandira Pal +1 more

Geometric Spin Hall effect of light (SHEL) has attracted considerable attention because of the universality of this variant of the spin Hall shift and its independence on the light-matter interactions and materials properties. However, the magnitude of geometric SHEL is typically very small, in the sub-wavelength domain, making it difficult for direct experimental observation. Here, we have applied weak measurement schemes to amplify and faithfully observe the geometric SHEL. In our experiment, the input beam is pre-selected in linear polarization basis (p- or slinear polarization) and post selections are done at nearly orthogonal linear polarizations (small angle ϵ away from the exact orthogonal).This results in weak value amplification (~cotϵ) of the resulting shift of the beam centroid. Moreover, this process also leads to selective conversion of spatial to angular nature of geometric SHEL, which along with the weak value amplification leads to manifold amplification of the resulting SHEL, enabling its reliable experimental detection. A key feature of our weak measurement scheme is that both the weak perturbation (tiny geometric SHEL) and the post selection are done simultaneously by a single optical element, namely, a linear polarizer. The dependence of the weak value of the geometric SHEL on the pre and the post selection of polarization states in both linear and elliptical basis were also investigated in details. The specifics of the different weak measurement schemes, various intriguing experimental manifestations of the weak value amplified geometric SHEL, their analysis / interpretation via polarization operator based treatment of weak measurements is presented here.

SPIE Nanophotonics•May 4, 2018•0 citations

Sub-Hertz Resonance by Weak Measurement

Jianming Wen, Weizhi Qu, Jian Sun +4 more

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus promise great potentials in precision measurements. Although frequency measurements offer the hitherto highest precision owing to stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we propose and demonstrate a WM-enhanced spectroscopy technique which is capable of narrowing the resonance to 0.1 Hz in a room-temperature atomic vapor cell. Potential of this technique for precision measurement is demonstrated through weak magnetic field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly-orthogonal manner, a sensitivity of $\text{7 fT/}\sqrt{\text{Hz}}$ near DC is achieved, using only one laser beam of $\text{7 }\text{\mu W}$ power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian, and shed new light in metrology and bio-magnetic field sensing applications.

Nonlinear Optics•Jan 1, 2019•0 citations
Weak measurements, which offer a significant signal enhancement with pre- and post-selections, have proven to be powerful for precision metrology. However, the measured precision of the parameter of interest is always limited by the post-selection-induced probe loss, especially in the presence of technical noise. In this paper, we investigate the optimal pre- and post-selections of weak measurements for precision metrology in the presence of technical noise. While weak measurements apply more generally, we experimentally measure the spin splitting induced by the spin Hall effect of light (SHEL) to approach this issue. The highest measured precision of the spin splitting can be obtained with the post-selected state in the nonlinear intermediate regime. Surprisingly, the pre- and post-selections for the largest weak-value amplification are incapable of estimation of the spin splitting, since the amplified shift is independent of the spin splitting. Our results are not restricted to the SHEL and could be applied to other parameter estimations with weak measurements.
We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
Photonic spin Hall effect (SHE) holds great potential applications in precision metrology. How to obtain a high measurement precision is an important issue to detect the photonic SHE. In this Letter, we propose using optimal preselection and postselection in weak measurements to enhance the measurement precision. We find that the maximum weak value and pointer shift can be obtained with an optimal overlap of preselection and postselection states. These findings offer the possibility for improving the precision of weak measurements and thereby have possible applications for accurately characterizing the parameters of nanostructures.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Since its first introduction over twenty years ago, weak measurements have gradually became an useful metrology tool in the laboratory. Due to its desirable amplification effect, a small physical variable can be detected with weak measurements. Spin splitting of light, which stems from the interaction between the spin and orbital angular momentum in optical reflection or refraction at the interface of mediums, is always a weak effect. However, the spin splitting of light can be detected easily with weak measurements. Remarkably, the spin splitting of light is sensitive to the physical parameter variations of system. Using the spin splitting as a probe, the physical parameter can be accurately estimated with weak measurements. Here, we review some of our works on precision metrology with weak measurements using the spin splitting of light as a probe, such as estimation of the magneto-optical constant of a magnetic film, determination of the focused beam waist, and measurement of the polarization state of light.
Geometric Spin Hall effect of light (SHEL) has attracted considerable attention because of the universality of this variant of the spin Hall shift and its independence on the light-matter interactions and materials properties. However, the magnitude of geometric SHEL is typically very small, in the sub-wavelength domain, making it difficult for direct experimental observation. Here, we have applied weak measurement schemes to amplify and faithfully observe the geometric SHEL. In our experiment, the input beam is pre-selected in linear polarization basis (p- or slinear polarization) and post selections are done at nearly orthogonal linear polarizations (small angle ϵ away from the exact orthogonal).This results in weak value amplification (~cotϵ) of the resulting shift of the beam centroid. Moreover, this process also leads to selective conversion of spatial to angular nature of geometric SHEL, which along with the weak value amplification leads to manifold amplification of the resulting SHEL, enabling its reliable experimental detection. A key feature of our weak measurement scheme is that both the weak perturbation (tiny geometric SHEL) and the post selection are done simultaneously by a single optical element, namely, a linear polarizer. The dependence of the weak value of the geometric SHEL on the pre and the post selection of polarization states in both linear and elliptical basis were also investigated in details. The specifics of the different weak measurement schemes, various intriguing experimental manifestations of the weak value amplified geometric SHEL, their analysis / interpretation via polarization operator based treatment of weak measurements is presented here.
Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus promise great potentials in precision measurements. Although frequency measurements offer the hitherto highest precision owing to stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we propose and demonstrate a WM-enhanced spectroscopy technique which is capable of narrowing the resonance to 0.1 Hz in a room-temperature atomic vapor cell. Potential of this technique for precision measurement is demonstrated through weak magnetic field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly-orthogonal manner, a sensitivity of 7 fT/Hz\text{7 fT/}\sqrt{\text{Hz}}7 fT/Hz​ near DC is achieved, using only one laser beam of $\text{7 }\text{\mu W}$ power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian, and shed new light in metrology and bio-magnetic field sensing applications.