I propose a new type of Heisenberg-limited quantum interferometer: a Mach-Zehnder interferometer whose two-mode input is frequency-degenerate twin beams, emitted by a type-II optical parametric oscillator above threshold, and from which a photon was subtracted.
We propose a Heisenberg-limited quantum interferometer whose input is twin optical beams from which one or more photons have been indistinguishably subtracted. Such an interferometer can yield Heisenberg-limited performance while at the same time giving a direct fringe reading, unlike for the twin-beam input of the Holland-Burnett interferometer. We propose a feasible experimental realization using a photon-number correlated source, such as nondegenerate parametric down-conversion, and perform realistic analyses of performance in the presence of loss and detector inefficiency.
We discuss the prospects of performing Heisenberg-limited quantum sensing and metrology using a Mach-Zehnder interferometer with input states that are superpositions of twin-Fock states and where photon number parity measurements are made on one of the output beams of the interferometer. This study is motivated by the experimental challenge of producing twin-Fock states on opposite sides of a beam splitter. We focus on the use of the so-called pair coherent states for this purpose and discuss a possible mechanism for generating them. We also discuss the prospect of using other superstitions of twin-Fock states, for the purpose of interferometry.
The best performance of a Mach-Zehnder interferometer is achieved with the input state $\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩$, NT being the total number of atoms or photons. This gives (i) a phase-shift error confidence ${C}_{68%}=2.67∕{N}_{T}$ with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling $\ensuremath{\sim}1∕{N}_{T}$ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.
The dependence of the quantum correlation of twin beams generated from a non-degenerate optical parametric oscillator on the analysis frequency was theoretically studied with semi-classical method. It was pointed out that the quantum entanglement is higher at lower analysis frequency. By means of a pair of unbalanced fiber Mach-Zehnder interferometers,the correlation noise spectrum of the intensity-difference and the phase-sum of twin beams with non-degenerate frequencies and total power of 20mW were experimentally measured,which were 3.1 and 1.3dB below the corresponding shot noise limit at 2MHz,respectively. The experimental results are in agreement with the theoretical predictions.