arXiv:quant-ph/0511059 · Physical Review A

Phase sensitivity of a Mach-Zehnder interferometer

Luca Pezzè, Augusto Smerzi

Published Jan 3, 2006• 80 citations
arXivHTMLPDF

Abstract

The best performance of a Mach-Zehnder interferometer is achieved with the input state $\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩$, ${N}_{T}$ being the total number of atoms or photons. This gives (i) a phase-shift error confidence ${C}_{68%}=2.67∕{N}_{T}$ with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling $\ensuremath{\sim}1∕{N}_{T}$ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.

DOI
10.1103/physreva.73.011801

Related papers

The Phase-sensitivity of a Mach-Zehnder Interferometer for Coherent Light

Jong-Tae Shin, Heonoh Kim, Goo-Dong Park +1 more

We have studied the sensitivity of four different phase shift measurement schemes with a Mach-Zehnder interferometer. The input light is considered to be in a coherent state and the detectors are assumed to be ideal with the quantum efficiency of unity. It is shown by direct calculation of the operators corresponding to the measurement schemes that the uncertainty of the phase-shift measurement is limited to the classical one $\frac{1}{\sqrt{m}}$ (m is the average number of the photons in the input state) regardless of the phase-shift measurement schemes.

Journal of the Optical Society of Korea•Mar 1, 1999•11 citations

Mach-Zehnder Interferometry at the Heisenberg Limit with Coherent and Squeezed-Vacuum Light

Luca Pezzè, Augusto Smerzi

We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where ${N}_{T}$ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter $r$ and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.

arXiv:0705.4631•Physical Review Letters•Feb 19, 2008•370 citations

Phase sensitivity of a quantum Mach-Zehnder interferometer for a coherent state input

Taesoo Kim, Heonoh Kim

The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.

Journal of the Optical Society of America B•Mar 12, 2009•6 citations

Phase sensitivity of a Mach-Zehnder interferometer with single-intensity and difference-intensity detection

Stefan Ataman, Anca Preda, Radu Ionicioiu

Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.

arXiv:1811.02412•Physical Review A•Oct 30, 2018•65 citations

Fidelity of quantum interferometers

Thomas B. Bahder, Paul A. Lopata

For a generic interferometer, the conditional probability density distribution $p(\ensuremath{\phi}\ensuremath{\mid}m)$, for the phase $\ensuremath{\phi}$ given measurement outcome $m$ will generally have multiple peaks. Therefore, the phase sensitivity of an interferometer cannot be adequately characterized by the standard deviation, such as $\mathrm{\ensuremath{\Delta}}\ensuremath{\phi}\ensuremath{\sim}1∕\sqrt{N}$ (the standard limit), or $\mathrm{\ensuremath{\Delta}}\ensuremath{\phi}\ensuremath{\sim}1∕N$ (the Heisenberg limit). We propose an alternative measure of phase sensitivity---the fidelity of an interferometer---defined as the Shannon mutual information between the phase shift $\ensuremath{\phi}$ and the measurement outcomes $m$. As an example application of interferometer fidelity, we consider a generic optical Mach-Zehnder interferometer, used as a sensor of a classical field. For the case where there exists no a priori information on the phase shift, we find the surprising result that maximally entangled state input leads to a lower fidelity than Fock state input, for the same photon number.

arXiv:quant-ph/0602123•Physical Review A•Nov 15, 2006•18 citations

Conclusive nonlinear phase sensitivity limit for a Mach-Zehnder interferometer with single-mode non-vacuum inputs

Jiandong Zhang, Zijing Zhang, Hu, Jun-Yan +4 more

Many works have stated that nonlinear interactions can improve phase sensitivity beyond the Heisenberg limit scaling of $1/N$ with $N$ being the mean photon number. This raises some open questions---among them the conclusive sensitivity limits with respect to single-mode inputs. Namely, when one of two inputs is vacuum, is there a shot-noise-style sensitivity bound on a nonlinear Mach-Zehnder interferometer? Within the reach of second-order nonlinear phase shifts, we make an attempt to provide an answer to this question. Based upon phase-averaging approach, this puzzle is partially resolved with careful calculations of the quantum Fisher information regarding three kinds of common inputs: Gaussian states, squeezed number states, and Schrödinger cat states. The results suggest that shot-noise-style sensitivity limit is no longer available, and the ideal candidate is squeezed vacuum.

arXiv:1906.10867•Jun 26, 2019•6 citations
The best performance of a Mach-Zehnder interferometer is achieved with the input state \ensuremath∣NT∕2+1⟩\ensuremath∣NT∕2\ensuremath−1⟩+\ensuremath∣NT∕2\ensuremath−1⟩\ensuremath∣NT∕2+1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath∣NT​∕2+1⟩\ensuremath∣NT​∕2\ensuremath−1⟩+\ensuremath∣NT​∕2\ensuremath−1⟩\ensuremath∣NT​∕2+1⟩, NT{N}_{T}NT​ being the total number of atoms or photons. This gives (i) a phase-shift error confidence {C}_{68%}=2.67∕{N}_{T} with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling \ensuremath∼1∕NT\ensuremath{\sim}1∕{N}_{T}\ensuremath∼1∕NT​ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.
We have studied the sensitivity of four different phase shift measurement schemes with a Mach-Zehnder interferometer. The input light is considered to be in a coherent state and the detectors are assumed to be ideal with the quantum efficiency of unity. It is shown by direct calculation of the operators corresponding to the measurement schemes that the uncertainty of the phase-shift measurement is limited to the classical one 1m\frac{1}{\sqrt{m}}m​1​ (m is the average number of the photons in the input state) regardless of the phase-shift measurement schemes.
We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where NT{N}_{T}NT​ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter rrr and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.
Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.
For a generic interferometer, the conditional probability density distribution $p(\ensuremath{\phi}\ensuremath{\mid}m)$, for the phase $\ensuremath{\phi}$ given measurement outcome mmm will generally have multiple peaks. Therefore, the phase sensitivity of an interferometer cannot be adequately characterized by the standard deviation, such as $\mathrm{\ensuremath{\Delta}}\ensuremath{\phi}\ensuremath{\sim}1∕\sqrt{N}$ (the standard limit), or $\mathrm{\ensuremath{\Delta}}\ensuremath{\phi}\ensuremath{\sim}1∕N$ (the Heisenberg limit). We propose an alternative measure of phase sensitivity---the fidelity of an interferometer---defined as the Shannon mutual information between the phase shift $\ensuremath{\phi}$ and the measurement outcomes mmm. As an example application of interferometer fidelity, we consider a generic optical Mach-Zehnder interferometer, used as a sensor of a classical field. For the case where there exists no a priori information on the phase shift, we find the surprising result that maximally entangled state input leads to a lower fidelity than Fock state input, for the same photon number.
Many works have stated that nonlinear interactions can improve phase sensitivity beyond the Heisenberg limit scaling of 1/N1/N1/N with NNN being the mean photon number. This raises some open questions---among them the conclusive sensitivity limits with respect to single-mode inputs. Namely, when one of two inputs is vacuum, is there a shot-noise-style sensitivity bound on a nonlinear Mach-Zehnder interferometer? Within the reach of second-order nonlinear phase shifts, we make an attempt to provide an answer to this question. Based upon phase-averaging approach, this puzzle is partially resolved with careful calculations of the quantum Fisher information regarding three kinds of common inputs: Gaussian states, squeezed number states, and Schrödinger cat states. The results suggest that shot-noise-style sensitivity limit is no longer available, and the ideal candidate is squeezed vacuum.