Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

The Quantum-Classical Boundary for Optical Interferometric Measurements

Patrick M. Birchall, Jonathan C. F. Matthews, Hugo V. Cable

Published Mar 15, 2016• 1 citation
OpenAlex

Related papers

Quantum interferometric measurements of temperature

Marcin Jarzyna, Marcin Zwierz

We provide a detailed description of the quantum interferometric thermometer, which is a device that estimates the temperature of a sample from the measurements of the optical phase. We rigorously analyze the operation of such a device by studying the interaction of the optical probe system prepared in a single-mode Gaussian state with a heated sample modeled as a dissipative thermal reservoir. We find that this approach to thermometry is capable of measuring the temperature of a sample in the nanokelvin regime. Furthermore, we compare the fundamental precision of quantum interferometric thermometers with the theoretical precision offered by the classical idealized pyrometers, which infer the temperature from a measurement of the total thermal radiation emitted by the sample. We find that the interferometric thermometer provides a superior performance in temperature sensing even when compared with this idealized pyrometer. We predict that interferometric thermometers will prove useful for ultraprecise temperature sensing and stabilization of quantum optical experiments based on the nonlinear crystals and atomic vapors.

arXiv:1412.5609•Physical Review A•Sep 10, 2015•21 citations

Quantum Limits in Optical Interferometry

Rafał Demkowicz-Dobrzański, Marcin Jarzyna, Jan Kołodyński

arXiv:1405.7703•Progress in optics•Jan 1, 2015•562 citations

Breaking the standard quantum limit for interferometric measurements

Alfredo Luis, Luis Lorenzo Sánchez-Soto

Optics Communications•May 1, 1992•17 citations

Quantum mechanics to classical mechanics boundary: N-slit heavy-atom interferometer

F.J. Duarte

The question of when quantum mechanics becomes classical mechanics is considered from an N-slit interferometric perspective. In this regard, the design of an N-slit heavy-atom interferometer is depicted and discussed. This work includes a conceptual and experimental discussion of the Diósi-Penrose hypothesis. Such hypothesis is found to be decoupled from the interferometric foundations of quantum mechanics. For the boundary situation beyond which interference, for heavy-atom aggregates, is no longer viable, a minimalist principle is suggested: spontaneous nonsuperposition, at the probability amplitude level. This is proposed as onset for the quantum → classical transition.

•Aug 21, 2024•0 citations

Quantum optical interferometry

Juan F. Hodelin

•Jan 1, 2008•0 citations

Quantum-noise-limited interferometric phase measurements

Andrew J. Stevenson, Malcolm B. Gray, Hans‐A. Bachor +1 more

Two schemes for interferometric optical phase measurement, with sensitivity limited only by quantum noise in the light, are analyzed. Direct detection is applicable to signals at modulation frequencies away from the technical noise of the light, so that quantum noise dominates the measurement. Alternatively signals otherwise obscured by classical optical noise may be recovered with a phase-modulation technique that shifts the signals to a quantum-noise-limited region of the photocurrent spectrum. The analysis is tested experimentally by using a polarimetric electric-field sensor. In the direct-detection scheme quantum-noise-limited performance produced a phase sensitivity of 0.25 µrad. The indirect scheme allowed subkilohertz signals to be extracted from classical noise 67 dB greater with sensitivity approaching the quantum noise limit.

Applied Optics•Jul 1, 1993•45 citations
We provide a detailed description of the quantum interferometric thermometer, which is a device that estimates the temperature of a sample from the measurements of the optical phase. We rigorously analyze the operation of such a device by studying the interaction of the optical probe system prepared in a single-mode Gaussian state with a heated sample modeled as a dissipative thermal reservoir. We find that this approach to thermometry is capable of measuring the temperature of a sample in the nanokelvin regime. Furthermore, we compare the fundamental precision of quantum interferometric thermometers with the theoretical precision offered by the classical idealized pyrometers, which infer the temperature from a measurement of the total thermal radiation emitted by the sample. We find that the interferometric thermometer provides a superior performance in temperature sensing even when compared with this idealized pyrometer. We predict that interferometric thermometers will prove useful for ultraprecise temperature sensing and stabilization of quantum optical experiments based on the nonlinear crystals and atomic vapors.
The question of when quantum mechanics becomes classical mechanics is considered from an N-slit interferometric perspective. In this regard, the design of an N-slit heavy-atom interferometer is depicted and discussed. This work includes a conceptual and experimental discussion of the Diósi-Penrose hypothesis. Such hypothesis is found to be decoupled from the interferometric foundations of quantum mechanics. For the boundary situation beyond which interference, for heavy-atom aggregates, is no longer viable, a minimalist principle is suggested: spontaneous nonsuperposition, at the probability amplitude level. This is proposed as onset for the quantum → classical transition.
Two schemes for interferometric optical phase measurement, with sensitivity limited only by quantum noise in the light, are analyzed. Direct detection is applicable to signals at modulation frequencies away from the technical noise of the light, so that quantum noise dominates the measurement. Alternatively signals otherwise obscured by classical optical noise may be recovered with a phase-modulation technique that shifts the signals to a quantum-noise-limited region of the photocurrent spectrum. The analysis is tested experimentally by using a polarimetric electric-field sensor. In the direct-detection scheme quantum-noise-limited performance produced a phase sensitivity of 0.25 µrad. The indirect scheme allowed subkilohertz signals to be extracted from classical noise 67 dB greater with sensitivity approaching the quantum noise limit.