Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Breaking the standard quantum limit for interferometric measurements

Alfredo Luis, Luis Lorenzo Sánchez-Soto

Published May 1, 1992• 17 citations
Publisher
DOI
10.1016/0030-4018(92)90147-j

Related papers

Interferometric Measurements Beyond the Shot-Noise Limit

Philippe Grangier, Richard E. Slusher, Bernard Yurke +1 more

NATO ASI series. Series B : Physics•Jan 1, 1989•1 citation

Quantum Limits in Optical Interferometry

Rafał Demkowicz-Dobrzański, Marcin Jarzyna, Jan Kołodyński

arXiv:1405.7703•Progress in optics•Jan 1, 2015•562 citations

Measuring Motion Below the Standard Quantum Limit by Strong Optomechanical Quantum Correlations

Junxin Chen, David Mason, Massimiliano Rossi +2 more

In interferometric displacement and force measurement, the tradeoff between imprecision noise and quantum backaction sets the standard quantum limit (SQL). By exploiting quantum correlations in an optomechanical system, we demonstrate the first sub-SQL interferometric measurement.

Quantum Information and Measurement (QIM)•Jan 1, 2019•0 citations

Measurements below the standard quantum limit in atomic interferometry

Franck Pereira dos Santos

•Jun 17, 2024•0 citations

Quantum limit of the resolution in force measurement in an active interferometric optical displacement transducer

Andrey B. Matsko

The quantum limit for resolution in force measurement using active interferometric optical transducer of displacement is proved to be less than the standard quantum limit (SQL) if one measures not the phase but a specially chosen quadrature amplitude in the output wave, squeezed by a mechanism of ponderomotive nonlinearity. Consideration of two types of active transducer having three-level atoms gain and parametric gain is given. Noises of spontaneous emission, fluctuations due to losses in mirrors and effect of radiative friction are taken into account.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 6, 1996•0 citations

Surpassing the Standard Quantum Limit Using an Optical Spring

T. J. Cullen, Ronald Pagano, Scott Aronson +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.

arXiv:2210.12222•Physical Review Letters•Sep 13, 2024•5 citations
The quantum limit for resolution in force measurement using active interferometric optical transducer of displacement is proved to be less than the standard quantum limit (SQL) if one measures not the phase but a specially chosen quadrature amplitude in the output wave, squeezed by a mechanism of ponderomotive nonlinearity. Consideration of two types of active transducer having three-level atoms gain and parametric gain is given. Noises of spontaneous emission, fluctuations due to losses in mirrors and effect of radiative friction are taken into account.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.