Journal of Applied Physics

Faraday-rotation Bell–Bloom atomic magnetometer using an alternating pump–probe beam

Songsong Li, Yi Zhang, Yuan Tian, Jie‐Hua Chen, Sihong Gu

Published Aug 25, 2021• 16 citations
Publisher

Abstract

We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.

DOI
10.1063/5.0057675

Related papers

Total-field atomic magnetometry using an elliptically-polarized frequency-modulated light beam for geomagnetic-field applications

Denis V. Brazhnikov, A. O. Makarov, K. S. Kozlova +10 more

We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field ($B$). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a $0.125$ cm$^3$ cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at $220$ fT/$\surd$Hz under $B$$\,\approx\,$$50$ $μ$T, while the shot-noise floor corresponds to $\approx\,$$20$ fT/$\surd$Hz. The bandwidth is estimated at $\approx\,$$1$ kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.

arXiv:2610.08031•Oct 6, 2026•0 citations

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•58 citations

Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Journal of Optoelectronics·laser•Jan 1, 2015•0 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•12 citations

Herriott-cavity-assisted all-optical atomic vector magnetometer

B. Cai, Chongyan Hao, Zheru Qiu +3 more

We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.

arXiv:2005.11196•Physical Review A•May 28, 2020•35 citations
We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.
We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field (BBB). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a 0.1250.1250.125 cm3^33 cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at 220220220 fT/√\surd√Hz under BBB ≈ \,\approx\,≈505050 μμμT, while the shot-noise floor corresponds to ≈ \approx\,≈202020 fT/√\surd√Hz. The bandwidth is estimated at ≈ \approx\,≈111 kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.