Symposium on Frequency Standards and Metrology

EXPERIMENTS WITH A NEW 201 Hg + ION CLOCK

Eric A. Burt, S. Taghavi-Larigani, S.N. Lea, John D. Prestage, Robert L. Tjoelker

Published May 1, 2009• 1 citation
Publisher

Abstract

In this paper we describe a new clock based on 201 Hg + . All previous mercury ion clocks have been based on 199 Hg + . We have recently completed construction of the 201 Hg + clock and will describe modifications to the design of our existing 199 Hg + clocks to accommodate the new isotope. We will also describe initial spectroscopic measurements of the hyperfine manifold, and possible future experiments. One experiment could place a limit on variations in the strong interaction fundamental constant ratio m q /Λ QCD .

DOI
10.1142/9789812838223_0043

Related papers

A new trapped ion clock based on 201HG+

S. Taghavi-Larigani, Eric A. Burt, S.N. Lea +2 more

There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave clock:199Hg+and201Hg+. Virtually all trapped mercury ion clocks to date have used the 199 isotope. We have begun to investigate the viability of a trapped ion clock based on201Hg+. We have measured the unperturbed frequency of the2S1/2F = 1, mF= 0 to2S1/2F = 2, mF=0 clock transition to be 29.9543658211(2) GHz. In this paper we describe initial measurements with201Hg+and new applications to clocks and fundamental physics.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•0 citations

Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

Eric A. Burt, Robert L. Tjoelker, S. Taghavi-Larigani

The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.

•Feb 1, 2011•0 citations

A One-Liter Mercury Ion Clock for Space and Ground Applications

John D. Prestage, Sang‒Ho Chung, Tuan M. Le +3 more

We describe progress towards the development of a small mercury (Hg+) ion clock suitable for space use. A small clock occupying a 1- to 2-liter volume and producing a stability of 10−12/ τ would significantly advance the state of space-qualified atomic clocks. Based on recent measurements, this technology should produce long-term stability as good as 10−15. I.

Interplanetary Network Progress Report•Nov 1, 2003•0 citations

Performance of Micro Mercury Trapped Ion Clock

Thai M. Hoang, Sang Kun Chung, Thanh Le +4 more

Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•10 citations

Trapping of Neutral Mercury Atoms and Prospects for Optical Lattice Clocks

Hidekazu Hachisu, K. Miyagishi, S. G. Porsev +5 more

We report vapor-cell magneto-optical trapping of Hg isotopes on the (1)S(0)-(3)P(1) intercombination transition. Six abundant isotopes, including four bosons and two fermions, were trapped. Hg is the heaviest nonradioactive atom trapped so far, which enables sensitive atomic searches for "new physics" beyond the standard model. We propose an accurate optical lattice clock based on Hg and evaluate its systematic accuracy to be better than 10;{-18}. Highly accurate and stable Hg-based clocks will provide a new avenue for the research of optical lattice clocks and the time variation of the fine-structure constant.

arXiv:0711.4638•Physical Review Letters•Feb 8, 2008•188 citations

Development of a molecular Hg2 clock to investigate fundamental physics

Marcin Witkowski, A. Linek, M. Zawada +1 more

Abstract We describe the development of an experimental system based on ultra-cold Hg atoms. We will use it to explore search possibilities for new interactions beyond the Standard Model. For this proposal, we will use two-color photoassociation and molecular clock transitions, and we will test the linearity of King’s plot with clock transitions in ultra-cold mercury.

Journal of Physics Conference Series•Nov 1, 2024•0 citations
In this paper we describe a new clock based on 201 Hg + . All previous mercury ion clocks have been based on 199 Hg + . We have recently completed construction of the 201 Hg + clock and will describe modifications to the design of our existing 199 Hg + clocks to accommodate the new isotope. We will also describe initial spectroscopic measurements of the hyperfine manifold, and possible future experiments. One experiment could place a limit on variations in the strong interaction fundamental constant ratio m q /Λ QCD .
There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave clock:199Hg+and201Hg+. Virtually all trapped mercury ion clocks to date have used the 199 isotope. We have begun to investigate the viability of a trapped ion clock based on201Hg+. We have measured the unperturbed frequency of the2S1/2F = 1, mF= 0 to2S1/2F = 2, mF=0 clock transition to be 29.9543658211(2) GHz. In this paper we describe initial measurements with201Hg+and new applications to clocks and fundamental physics.
The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.
Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.
We report vapor-cell magneto-optical trapping of Hg isotopes on the (1)S(0)-(3)P(1) intercombination transition. Six abundant isotopes, including four bosons and two fermions, were trapped. Hg is the heaviest nonradioactive atom trapped so far, which enables sensitive atomic searches for "new physics" beyond the standard model. We propose an accurate optical lattice clock based on Hg and evaluate its systematic accuracy to be better than 10;{-18}. Highly accurate and stable Hg-based clocks will provide a new avenue for the research of optical lattice clocks and the time variation of the fine-structure constant.