Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Performance of Micro Mercury Trapped Ion Clock

Thai M. Hoang, Sang Kun Chung, Thanh Le, John D. Prestage, Lin Yi, Robert L. Tjoelker, Nan Yu

Published Apr 1, 2019• 10 citations
Publisher

Abstract

Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.

DOI
10.1109/fcs.2019.8856065

Related papers

Stability Demonstration of a 15-cc Mercury-Ion Vacuum Trap Tube

Thai M. Hoang, Sang Kun Chung, Thanh Le +4 more

In this paper, we report our recent effort on developing a micro mercury trapped ion atomic clock. In particular, we present preliminary results of a mercury-ion clock using a 15-cc vacuum trap tube. The mercury-ion clock can achieve a short-term fractional frequency instability of 1.5 ×10!12τ!1/2and reach a fractional frequency instability of 3 ×10!14after averaging for an hour. The clock can remain at the 10!14fractional frequency instability level up to several hours. Furthermore, the sealed 15-cc vacuum tube has demonstrated a very long ion lifetime of over two hundred days. We also investigated the mercury vapor density inside the vacuum trap tube by measuring the coherence time of the microwave clock transition.

Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)•Jul 1, 2020•4 citations

Micro Ion Frequency Standard

Peter D. D. Schwindt, Roy H. Olsson, K.E. Wojciechowski +7 more

We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.

•Nov 19, 2009•2 citations

MERCURY TRAPPED ION FREQUENCY STANDARD FOR SPACE APPLICATIONS

Robert L. Tjoelker, Eric A. Burt, S. CHUNG +9 more

We report on the development of a small, low mass and power, and high stability mercury trapped ion frequency standard for spaceflight. The design performance goal is fractional frequency stability reaching into the 10 -6 range with technologies that allow for 10 years of continuous operational life. Key system elements include using a nitrogen buffer gas for long vacuum pump life and a multi-pole ion trap to minimize sensitivity to the second order Doppler shift.

Symposium on Frequency Standards and Metrology•May 1, 2002•13 citations

Compact Microwave Mercury Ion Clock for Deep-Space Applications

John D. Prestage, Sang Kun Chung, Lawrence Lim +1 more

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~1-2times10-13at 1 second, averaging to 10-15at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2times10-13second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a ~400degC tube bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligible diffusion losses will occur over the operation lifetime.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2007•9 citations

Integrated physics package of micromercury trapped ion clock with 10−14-level frequency stability

Thai M. Hoang, Sang Kun Chung, Thanh Le +8 more

Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of 1×10−11τ−1/2 down to 5×10−14 after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.

Applied Physics Letters•Jul 26, 2021•16 citations

Micro ion frequency standard

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +8 more

We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171Yb+ ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT) program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm3, and has a long-term frequency stability of 10-14 at one month. One of the significant challenges will be to develop miniature single-frequency lasers at 369 nm and 935 nm and the optical systems to deliver light to the ions and to collect ion fluorescence on a detector.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 4, 2011•2 citations
Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.
In this paper, we report our recent effort on developing a micro mercury trapped ion atomic clock. In particular, we present preliminary results of a mercury-ion clock using a 15-cc vacuum trap tube. The mercury-ion clock can achieve a short-term fractional frequency instability of 1.5 ×10!12τ!1/2and reach a fractional frequency instability of 3 ×10!14after averaging for an hour. The clock can remain at the 10!14fractional frequency instability level up to several hours. Furthermore, the sealed 15-cc vacuum tube has demonstrated a very long ion lifetime of over two hundred days. We also investigated the mercury vapor density inside the vacuum trap tube by measuring the coherence time of the microwave clock transition.
We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.
We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~1-2times10-13at 1 second, averaging to 10-15at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2times10-13second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a ~400degC tube bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligible diffusion losses will occur over the operation lifetime.
Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of 1×10−11τ−1/2 down to 5×10−14 after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.
We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171Yb+ ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT) program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm3, and has a long-term frequency stability of 10-14 at one month. One of the significant challenges will be to develop miniature single-frequency lasers at 369 nm and 935 nm and the optical systems to deliver light to the ions and to collect ion fluorescence on a detector.