Applied Physics Letters

Single-beam three-axis atomic magnetometer

Haichao Huang, Haifeng Dong, Lin Chen, Yang Gao

Published Aug 8, 2016• 78 citations
Publisher

Abstract

A single-beam atomic magnetometer being operated near zero-field and measuring three-axis fields simultaneously is demonstrated. We produce a rotating field on the x-0-y plane with the frequency of 90 Hz and a modulation field in the z axis at 130 Hz. The rotating field enables a nonzero z axis output when the transverse fields are zeroed using feedback systems. Based on the phase difference of π/2, x and y axes fields can be measured using one lock-in amplifier. Magnetic field sensitivities of 300 fT/Hz1∕2 in x and y axes and 3 pT/Hz1∕2 in the z axis are achieved.

DOI
10.1063/1.4960971

Related papers

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•23 citations

Three-axis atomic magnetometer based on spin precession modulation

Hao Huang, Hai Feng Dong, Xiaofei Hu +2 more

We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.

Applied Physics Letters•Nov 2, 2015•63 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•16 citations

Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams

Lin Li, Junjian Tang, Binbin Zhao +1 more

In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.

Results in Physics•Jul 13, 2023•7 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•125 citations
A single-beam atomic magnetometer being operated near zero-field and measuring three-axis fields simultaneously is demonstrated. We produce a rotating field on the x-0-y plane with the frequency of 90 Hz and a modulation field in the z axis at 130 Hz. The rotating field enables a nonzero z axis output when the transverse fields are zeroed using feedback systems. Based on the phase difference of π/2, x and y axes fields can be measured using one lock-in amplifier. Magnetic field sensitivities of 300 fT/Hz1∕2 in x and y axes and 3 pT/Hz1∕2 in the z axis are achieved.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).