Theoretical and Experimental Study of Rising Zeeman Slower Efficiency use compensatory Coils

Hong Chang

Published Jan 1, 2011• 0 citations
OpenAlex

Abstract

We present a Zeeman Slower used for strontium optical clock.Adding compensatory coil can increase slower actual distance and ultimate magnetic field gradient,thus increasing captured atom number in Strontium first cooling stage(blue MOT).Theoretical analysis Zeeman slower constructed in new method can trapping 31.17% more atoms than made by a single set of coil.We measured the velocity distribution of atomic beam use time-of-flight method.The most probable velocity decreased from 380m/s to 43m/s,the width also become narrower.Experiment study show that two coils Zeeman slower can trap 1.81×10688Sr atoms in first cooling stage.While single coil Zeeman slower can trap 1.26×106 atoms in same experimental condition.Therefore adding compensatory coils increase trapping atom number by 30.4%,consistent with the theoretical analysis.

Related papers

Maximized cooling efficiency for a Zeeman slower operating at optimized magnetic field profile

Zhuan-Xian Xiong, Yun Long, Huixing Xiao +3 more

We build a Zeeman slower with consecutive coils and use it to load an Yb magneto-optical trap (MOTs).Cooling efficiency is measured by the fluorescence intensity of the atomic cloud trapped by the MOT.An optimized magnetic field profile can acquire the maximum cooling efficiency, corresponding to a good compromise between the smaller magnetic field mismatch and the high capture velocity.Our studies provide useful information on how the performance of the Zeeman slower can be improved.

Chinese Optics Letters•Jan 1, 2011•1 citation

Miniaturization of physics system in Sr optical clock

Zhao Fang-Jing, Gao Feng, 韩建新 HAN Jian-xin +6 more

The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.

Acta Physica Sinica•Jan 1, 2018•4 citations

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations

Designing Zeeman slower for strontium atoms - towards optical atomic clock

Marcin Bober, Jerzy Zachorowski, Wojciech Gawlik

We report on design and construction of a Zeeman slower for strontium atoms which will be used in an optical atomic clock experiment. The paper describes briefly required specifications of the device, possible solutions, and concentrates on the chosen design. The magnetic field produced by the built Zeeman slower has been measured and compared with the simulations. The system consisting of an oven and Zeeman slower are designed to produce an atomic beam of 10-12 s-1 flux and final velocity of ~30 m/s.

arXiv:1006.1554•Optica Applicata•Jun 8, 2010•10 citations

Zeeman slowing atoms using the magnetic field from a magneto-optical trap

Wen Yan, Yuan Yao, Yuxin Sun +3 more

We study a Zeeman slower using the magnetic field generated by a pair of coils for a magneto-optical trap. The efficiency of the Zeeman slower is shown to be dependent on the intensity and frequency detuning of the laser light for slowing the atoms. With the help of numerical analysis, optimal experimental parameters are explored. Experimentally, the optimal frequency detuning and intensity of the slowing beam are explored, and 4 × 107 ytterbium atoms are trapped in the magneto-optical trap.

Chinese Optics Letters•Jan 1, 2019•1 citation

Trapping and cooling of atoms

C. J. Pethick, H. Smith

The advent of the laser opened the way to the development of powerful new methods for manipulating and cooling atoms which were exploited in the realization of Bose–Einstein condensation in alkali atom vapours. To set the stage we describe a typical experiment, which is shown schematically in Fig. 4.1. A beam of sodium atoms emerges from an oven at a temperature of about 600 K, corresponding to a speed of about 800 m s –1 , and is then passed through a so-called Zeeman slower, in which the velocity of the atoms is reduced to about 30 m s –1 , corresponding to a temperature of about 1 K. In the Zeeman slower, a laser beam propagates in the direction opposite that of the atomic beam, and the radiation force produced by absorption of photons retards the atoms. Due to the Doppler effect, the frequency of the atomic transition in the laboratory frame is not generally constant, since the atomic velocity varies. However, by applying an inhomogeneous magnetic field designed so that the Doppler and Zeeman effects cancel, the frequency of the transition in the rest frame of the atom may be held fixed. On emerging from the Zeeman slower the atoms are slow enough to be captured by a magneto-optical trap (MOT), where they are further cooled by interactions with laser light to temperatures of order 100 μK. Another way of compensating for the changing Doppler shift is to increase the laser frequency in time, which is referred to as ‘chirping’. In other experiments the MOT is filled by transferring atoms from a second MOT where atoms are captured directly from the vapour.

Cambridge University Press eBooks•Nov 29, 2001•0 citations
We present a Zeeman Slower used for strontium optical clock.Adding compensatory coil can increase slower actual distance and ultimate magnetic field gradient,thus increasing captured atom number in Strontium first cooling stage(blue MOT).Theoretical analysis Zeeman slower constructed in new method can trapping 31.17% more atoms than made by a single set of coil.We measured the velocity distribution of atomic beam use time-of-flight method.The most probable velocity decreased from 380m/s to 43m/s,the width also become narrower.Experiment study show that two coils Zeeman slower can trap 1.81×10688Sr atoms in first cooling stage.While single coil Zeeman slower can trap 1.26×106 atoms in same experimental condition.Therefore adding compensatory coils increase trapping atom number by 30.4%,consistent with the theoretical analysis.
The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.
We report on design and construction of a Zeeman slower for strontium atoms which will be used in an optical atomic clock experiment. The paper describes briefly required specifications of the device, possible solutions, and concentrates on the chosen design. The magnetic field produced by the built Zeeman slower has been measured and compared with the simulations. The system consisting of an oven and Zeeman slower are designed to produce an atomic beam of 10-12 s-1 flux and final velocity of ~30 m/s.
The advent of the laser opened the way to the development of powerful new methods for manipulating and cooling atoms which were exploited in the realization of Bose–Einstein condensation in alkali atom vapours. To set the stage we describe a typical experiment, which is shown schematically in Fig. 4.1. A beam of sodium atoms emerges from an oven at a temperature of about 600 K, corresponding to a speed of about 800 m s –1 , and is then passed through a so-called Zeeman slower, in which the velocity of the atoms is reduced to about 30 m s –1 , corresponding to a temperature of about 1 K. In the Zeeman slower, a laser beam propagates in the direction opposite that of the atomic beam, and the radiation force produced by absorption of photons retards the atoms. Due to the Doppler effect, the frequency of the atomic transition in the laboratory frame is not generally constant, since the atomic velocity varies. However, by applying an inhomogeneous magnetic field designed so that the Doppler and Zeeman effects cancel, the frequency of the transition in the rest frame of the atom may be held fixed. On emerging from the Zeeman slower the atoms are slow enough to be captured by a magneto-optical trap (MOT), where they are further cooled by interactions with laser light to temperatures of order 100 μK. Another way of compensating for the changing Doppler shift is to increase the laser frequency in time, which is referred to as ‘chirping’. In other experiments the MOT is filled by transferring atoms from a second MOT where atoms are captured directly from the vapour.