Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Physics Sae Mulli

Temperature Measurement by Using Time of Flight to Magneto Optically Trapped $^{87}$Rb Atoms

Hoon Yu, Hyun Kyung Lee, Mi Hyun Choi, Jung Bog Kim

Published Apr 30, 2012• 2 citations
Publisher
DOI
10.3938/npsm.62.399

Related papers

Absolute atomic collision cross section measurements using Rb atoms confined in magneto-optic and magnetic traps

David E. Fagnan, J. Wang, Bruce G. Klappauf +2 more

Bulletin of the American Physical Society•May 21, 2009•0 citations

Temperature measurements of laser trapped rubidium

T. Dinneen, Christopher D. Wallace, K. Y. N. Tan +2 more

Temperatures of rubidium atoms confined in a magneto-optical trap have been measured using time-of-flight. By varying the parameters of the trap, we find that lower temperatures are obtained with lower laser intensities, larger laser detunings, lower atomic densities, and with the 85 vs. the 87 isotope. Temperatures are below the Doppler limit (140 {mu}K for Rb) in most cases. By measuring the size of the trapped cloud as well as the temperature, we can infer the spring constant of the trap. For comparison purposes, we can measure temperatures in optical molasses by turning off the magnetic field of the trap.

Bulletin of the American Physical Society•May 1, 1993•0 citations

Temperature determination for magneto optical trapped atoms using a single parameter transient absorption

R.R. Silva, K. M. F. Magalhães, E. A. L. Henn +2 more

Optics Communications•May 27, 2006•5 citations

Measurement of the Number and Temperature of the Cold atoms EIT Medium

Hai Wang

The experimental setup for cooling and trapping~(87)Rb atoms in magneto-optical trap(MOT) and the process of them are briefly introduced in this paper.The number of cold atoms is measured by detecting the fluorescence emitted from~(87)Rb atoms.The laser probe beam is set at the positions which are 4mm,7mm,10mm below the atoms cloud,the short-distance time-of-flight(TOF) Absorption signals are obtained during the falling of atoms.The average temperature of cold atoms is obtained by numerical simulating.The results show that the number of cold atoms is about 10~(9),the density is about 10~(11)/cm~3 and the cooling temperature of atomic cloud is about 200 μK,such cold atoms can be used as good EIT medium.

Acta Sinica Quantum Optica•Jan 1, 2007•0 citations

Measurements of temperature and the Zeeman shift of trapped Rb atoms using a coherent transient technique

I. Y. Chan, A. Andreyuk, M. Weel +3 more

APS•May 1, 2004•0 citations

Characterization of the Magneto-Optical Trap for Rb Atoms

J. W. F. Liwag, Joseph Manyaga, Marlon Patiño +2 more

A magneto-optical trap (MOT) for rubidium (Rb) atoms has been in operation at the University of San Carlos Optoelectronics Research Laboratory in Cebu City since 1998. The experimental design for this MOT is based on the system described by Wieman et al. (1995). This system formed the backbone of the research which resulted in the first observation of Bose-Einstein condensation (BEC) by the same group in 1995. An essential step for realizing this remarkable result was the accuracy in the timing mechanism of the experiment. To obtain an MOT in which we can switch the laser and magnetic fields with sub-millisecond accuracy, we have put considerable efforts to realize a computer-controlled system. Previous measurements have been used to validate our new results. The realization of a fast switch for the trapping laser creates the opportunity to measure time-of-flight (TOF) signals. These ballistic measurements can be used to infer the temperature of the cloud of trapped atoms. We hope to continue working on this automated system of the MOT towards BEC as a long-term goal of our research group.

Science Diliman•Jul 4, 2012•1 citation
Temperature Measurement by Using Time of Flight to Magneto Optically Trapped 87^{87}87Rb Atoms
Temperatures of rubidium atoms confined in a magneto-optical trap have been measured using time-of-flight. By varying the parameters of the trap, we find that lower temperatures are obtained with lower laser intensities, larger laser detunings, lower atomic densities, and with the 85 vs. the 87 isotope. Temperatures are below the Doppler limit (140 {mu}K for Rb) in most cases. By measuring the size of the trapped cloud as well as the temperature, we can infer the spring constant of the trap. For comparison purposes, we can measure temperatures in optical molasses by turning off the magnetic field of the trap.
The experimental setup for cooling and trapping~(87)Rb atoms in magneto-optical trap(MOT) and the process of them are briefly introduced in this paper.The number of cold atoms is measured by detecting the fluorescence emitted from~(87)Rb atoms.The laser probe beam is set at the positions which are 4mm,7mm,10mm below the atoms cloud,the short-distance time-of-flight(TOF) Absorption signals are obtained during the falling of atoms.The average temperature of cold atoms is obtained by numerical simulating.The results show that the number of cold atoms is about 10~(9),the density is about 10~(11)/cm~3 and the cooling temperature of atomic cloud is about 200 μK,such cold atoms can be used as good EIT medium.
A magneto-optical trap (MOT) for rubidium (Rb) atoms has been in operation at the University of San Carlos Optoelectronics Research Laboratory in Cebu City since 1998. The experimental design for this MOT is based on the system described by Wieman et al. (1995). This system formed the backbone of the research which resulted in the first observation of Bose-Einstein condensation (BEC) by the same group in 1995. An essential step for realizing this remarkable result was the accuracy in the timing mechanism of the experiment. To obtain an MOT in which we can switch the laser and magnetic fields with sub-millisecond accuracy, we have put considerable efforts to realize a computer-controlled system. Previous measurements have been used to validate our new results. The realization of a fast switch for the trapping laser creates the opportunity to measure time-of-flight (TOF) signals. These ballistic measurements can be used to infer the temperature of the cloud of trapped atoms. We hope to continue working on this automated system of the MOT towards BEC as a long-term goal of our research group.