Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A MEASUREMENT CIRCUIT TO TEST BELL'S INEQUALITIES IN A MACROSCOPIC SUPERCONDUCTING DEVICE

Claudia D. Tesche

Published Mar 1, 1991• 0 citations
Publisher

Abstract

A measurement circuit for the flux state of an rf SQUID is described which has elements analogous to those used in a conventional EPR experiment. These elements include dc SQUID switches which act like polarizers, and dissipative dc SQUID magnetometers which act like particle detectors. These elements can be used in an experimental search for violations of macrorealism and non-invasive measurability in a macroscopic system.

DOI
10.1142/9789814439251_0032

Related papers

A hysteretic dc SQUID reading the flux states of an rf SQUID

C. Cosmelli, P. Carelli, Maria Gabriella Castellano +3 more

We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•12 citations

RF SQUID BASED DEVICES FOR MQC

Luigi Longobardi, Valentina Corato, C. Granata +4 more

We present different types of integrated planar SQUID devices in view of Macroscopic Quantum Coherence (MQC) experiments. These devices include an rf SQUID as a probe to test the MQC, coupled to a readout system based on a dc SQUID sensor. Both dc SQUID and flux transformer are in a gradiometric configuration to minimize the electromagnetic noise from environment. We report data on dc SQUID performances as well as preliminary results on the decay from the metastable flux state for rf SQUID-based devices above the crossover temeperature (classical limit).

International Journal of Modern Physics B•Mar 10, 2003•0 citations

Josephson device for quantum experiments

C. Granata, Valentina Corato, Luigi Longobardi +3 more

We present the characterization of a fully integrated Josephson device consisting of a rf-superconducting quantum interference device (SQUID) coupled to a readout system based on a dc SQUID sensor. Particular care in the design is devoted to minimize the electromagnetic noise coming from the environment. We report data on dc SQUID performances as well as on the decay rate from metastable flux states of the rf SQUID in the classical regime. The low dissipation level and the good insulation of the probe from the external noise are encouraging in view of macroscopic quantum experiments.

Applied Physics Letters•Apr 22, 2002•20 citations

Macroscopic quantum device based on a rf SQUID system

C. Granata, Valentina Corato, Luigi Longobardi +4 more

The growing amount of theoretical interest in the area of quantum computing have stimulated in recent years research with the aim of developing a corresponding technology. Superconducting Josephson systems appear to be among the most promising candidates. We present the characterization of a fully integrated Josephson device consisting of an RF SQUID coupled to a readout system based on a dc SQUID sensor. We report measurements of the dc SQUID performances showing a high intrinsic responsivity and a low flux noise, giving a good signal to noise ratio in the small signal mode. In the classical regime data on the decay rate from the metastable flux states of RF SQUID are also reported. The low dissipation level and the good insulation of the probe from the external noise are encouraging in view of macroscopic quantum experiments. Work is in progress to improve the design of the device to increase its application capability toward the quantum regime.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•2 citations

Tracing the characteristics of a flux qubit with a hysteretic dc-superconducting quantum interference device comparator

Maria Gabriella Castellano, F. Chiarello, Roberto Leoni +6 more

A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.

Journal of Applied Physics•Dec 4, 2003•4 citations

Observation of macroscopic quantum tunnelling in a rf superconducting quantum interference device system

Valentina Corato, S. Rombetto, P. Silvestrini +3 more

We present the experimental observation of the effects of macroscopic quantum tunnelling in a SQUID device, consisting of a rf SQUID coupled to a readout system based on a dc SQUID sensor. Data on the decay rate from the metastable flux states of a rf SQUID are reported, both in the classical and quantum regimes. The low dissipation level and the good insulation of the probe from external noise are encouraging in view of building a macroscopic quantum coherent system.

Superconductor Science and Technology•Apr 15, 2004•9 citations
A measurement circuit for the flux state of an rf SQUID is described which has elements analogous to those used in a conventional EPR experiment. These elements include dc SQUID switches which act like polarizers, and dissipative dc SQUID magnetometers which act like particle detectors. These elements can be used in an experimental search for violations of macrorealism and non-invasive measurability in a macroscopic system.
We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.
We present different types of integrated planar SQUID devices in view of Macroscopic Quantum Coherence (MQC) experiments. These devices include an rf SQUID as a probe to test the MQC, coupled to a readout system based on a dc SQUID sensor. Both dc SQUID and flux transformer are in a gradiometric configuration to minimize the electromagnetic noise from environment. We report data on dc SQUID performances as well as preliminary results on the decay from the metastable flux state for rf SQUID-based devices above the crossover temeperature (classical limit).
We present the characterization of a fully integrated Josephson device consisting of a rf-superconducting quantum interference device (SQUID) coupled to a readout system based on a dc SQUID sensor. Particular care in the design is devoted to minimize the electromagnetic noise coming from the environment. We report data on dc SQUID performances as well as on the decay rate from metastable flux states of the rf SQUID in the classical regime. The low dissipation level and the good insulation of the probe from the external noise are encouraging in view of macroscopic quantum experiments.
The growing amount of theoretical interest in the area of quantum computing have stimulated in recent years research with the aim of developing a corresponding technology. Superconducting Josephson systems appear to be among the most promising candidates. We present the characterization of a fully integrated Josephson device consisting of an RF SQUID coupled to a readout system based on a dc SQUID sensor. We report measurements of the dc SQUID performances showing a high intrinsic responsivity and a low flux noise, giving a good signal to noise ratio in the small signal mode. In the classical regime data on the decay rate from the metastable flux states of RF SQUID are also reported. The low dissipation level and the good insulation of the probe from the external noise are encouraging in view of macroscopic quantum experiments. Work is in progress to improve the design of the device to increase its application capability toward the quantum regime.
A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.