Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

171 YB + SINGLE-ION OPTICAL FREQUENCY STANDARDS

Chr. Tamm, B. Lipphardt, T. E. Mehlstäubler, Maksim V. Okhapkin, I. Sherstov, Björn Stein, E. Peik

Published May 1, 2009• 0 citations
Publisher

Abstract

Singly ionized ytterbium offers a number of possibilities to realize frequency standards in the optical frequency range. Two narrow-linewidth reference transitions, one at a wavelength 436 nm and the other at 467 nm, are of particular interest for practical implementations of single-ion optical clocks. The frequency ratio of these transitions is expected to be a very sensitive probe for the constancy of the fine structure constant. We outline our related experimental work and in particular the status of the 436 nm (688 THz) single-ion optical frequency standard developed at PTB.

DOI
10.1142/9789812838223_0026

Related papers

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Combined optical–infrared single-ion frequency standard

Philip H. Taylor, M. Roberts, G. P. Barwood +1 more

A combined infrared-optical frequency-standard scheme has been demonstrated with a single ion of ytterbium. The optical (2)S(1/2)-(2)D(5/2) reference transition at 411 nm and the infrared (2)F(7/2)-(2)D(5/2) 3.43-microm transition were driven sequentially. The structure of the infrared (2)F(7/2)-(2)D(5/2) reference transition at 3.43 microm has also been studied. Infrared transition linewidths of 300 kHz were observed. The output of a Nd:YAG laser and an extended-cavity diode laser were difference-frequency mixed in a crystal of AgGaS(2) to produce narrow-linewidth light at 3.43 microm . Both lasers were frequency stabilized to high-finesse reference cavities.

Optics Letters•Feb 15, 1998•18 citations

Towards a High-Performance Optical Clock Based on Single 171-Yb Ion

Yani Zuo, Shaoyang Dai, Shiying Cao +5 more

With the development of optical frequency comb and ultra-stable laser techniques, the performance of optical frequency standards has been improved significantly over the past decades. Single charged Yb ions have an alkali-like atomic structure and have ultra-long storage time. And the ytterbium single-ion optical frequency standards have two clock transitions (E2 & E3). In this paper, we will introduce the progress in the development of a highly accurate optical frequency standard based on single ytterbium-171 ion at the National Institute of Metrology (NIM), China.

IEEE Optoelectronics Global Conference (OGC)•Sep 15, 2021•2 citations

Yb+ single-ion optical frequency standard with systematic uncertainty at the 10−17 level

Nils Huntemann, B. Lipphardt, Maksim V. Okhapkin +2 more

The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

Progress toward a single ytterbium ion optical clock

Paul Taylor, Stephen A. Webster, Matthew Roberts +3 more

Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations
Singly ionized ytterbium offers a number of possibilities to realize frequency standards in the optical frequency range. Two narrow-linewidth reference transitions, one at a wavelength 436 nm and the other at 467 nm, are of particular interest for practical implementations of single-ion optical clocks. The frequency ratio of these transitions is expected to be a very sensitive probe for the constancy of the fine structure constant. We outline our related experimental work and in particular the status of the 436 nm (688 THz) single-ion optical frequency standard developed at PTB.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
A combined infrared-optical frequency-standard scheme has been demonstrated with a single ion of ytterbium. The optical (2)S(1/2)-(2)D(5/2) reference transition at 411 nm and the infrared (2)F(7/2)-(2)D(5/2) 3.43-microm transition were driven sequentially. The structure of the infrared (2)F(7/2)-(2)D(5/2) reference transition at 3.43 microm has also been studied. Infrared transition linewidths of 300 kHz were observed. The output of a Nd:YAG laser and an extended-cavity diode laser were difference-frequency mixed in a crystal of AgGaS(2) to produce narrow-linewidth light at 3.43 microm . Both lasers were frequency stabilized to high-finesse reference cavities.
With the development of optical frequency comb and ultra-stable laser techniques, the performance of optical frequency standards has been improved significantly over the past decades. Single charged Yb ions have an alkali-like atomic structure and have ultra-long storage time. And the ytterbium single-ion optical frequency standards have two clock transitions (E2 & E3). In this paper, we will introduce the progress in the development of a highly accurate optical frequency standard based on single ytterbium-171 ion at the National Institute of Metrology (NIM), China.
The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.
Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .