Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Polarizing Ultra-Cold Neutrons for the Superconducting Trap PENeLOPE

R. Picker, Wolfgang Schreyer, F. HAAS, F. J. Hartmann, Martin Jan Losekamm, Stephan Martin Paul, R. Stoepler, Christian Tietze

Published Mar 27, 2014• 1 citation
Publisher

Abstract

PENeLOPE (Precision Experiment on the Neutron Lifetime Operating with Proton Extraction) is a novel experiment to measure the lifetime of the free neutron. It features magneto-gravitational storage of ultra-cold neutrons; only one spin state of the neutrons can be stored magnetically, hence a polarization system is necessary. In contrast to most other magnetic storage experiments, the magnetic field is ramped up from zero after filling, which results in a complete spatial and energetic separation of the two spin states; this allows the use of novel techniques in cleaning the trap from the unwanted spin state in addition to pre-polarization. A polarization of 99.98% should be achievable.

DOI
10.1142/9789814571678_0016

Related papers

A magnetic trap for high-field seeking neutron spin states

Th. Brenner, S. Chesnevskaya, P. Fierlinger +7 more

A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

Physics Letters B•Dec 24, 2014•2 citations

Quantum effects in a one-dimensional magnetic gravitational trap for ultracold neutrons

Aleksandr I Frank, Viktor G. Nosov

The problem of storing ultracold neutrons over a plane magnetic mirror in the presence of gravity is considered. For neutrons with a definite polarization, the sum of the magnetic and gravitational potentials can have a minimum and, hence, form a magnetic gravitational trap. For low energies of vertical motion, the neutron state in this well is quantized. The possibility of accomplishing the corresponding quantum gravitational experiment is analyzed.

Journal of Experimental and Theoretical Physics Letters•Apr 1, 2004•7 citations

First ever storage of ultracold neutrons in a magnetic trap made of permanent magnets

В. Ф. Ежов, A. Z. Andreev, A.A. Glushkov +13 more

Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.

Journal of Research of the National Institute of Standards and Technology•Jul 1, 2005•23 citations

Vibration-Induced Loss of Ultra-Cold Neutrons in a Magneto-Gravitational Trap

D. J. Salvat, P. L. Walstrom

We investigate the loss of Ultra-Cold Neutrons (UCN) in a magneto-gravitational trap due to microphonic vibrations. The presence of vibrations may cause the spectrum of trapped UCN to shift to an energy higher than the potential energy of the trap, and UCN may therefore escape the trap on a time scale similar to the neutron β decay lifetime of ~ 881 s. For the geometry of the UCN τ trap at Los Alamos National Laboratory (LANL), we present a simplified model of the trap in the presence of vibrations, and observe the magnitude of energy transfers that are imparted on the UCN. From this, we estimate the frequency and amplitude of vibrations that may cause the loss of 10 −4 of the neutrons over a storage time of 1000 s. We use an accelerometer to measure the frequency and amplitude of microphonic vibrations in the UCN experimental area at LANL, and find them to be similar to those used in the model. Potential implications and future work are discussed.

•Mar 27, 2014•2 citations

Characterizing the AC-MOT

M. Anholm

Magneto-Optical Traps (MOTs) have long been used to produce samples of cold trapped neutral atoms, which can be used in the measurement of a variety of physical quantities and theories. Until recently, one limitation of this type of trap was the necessity for the presence of a relatively large magnetic field which would decay only slowly after the trapping mechanism was turned off. This residual magnetic field is expected to partially destroy any atomic polarization induced, for example, by optical pumping. As a result, the precision of any physical measurement which requires polarization is limited. We will discuss the construction of our version of a newer type of MOT, the AC-MOT [2], which is designed specifically so as to minimize residual magnetic fields. We have found that our AC-MOT has lifetimes and cloud sizes similar to those we measured in our DC-MOT. We intend to use a trap similar to this in upcoming nuclear beta decay parity-violation measurements. We also discuss the numerical evolution of the optical Bloch equations in the presence of transverse and longitudinal magnetic fields, so as to quantify the effect of a magnetic field on atomic polarization.

•Jan 1, 2014•0 citations

Creating long-lived neutral-atom traps in a cryogenic environment

Phil A. Willems, Kenneth G. Libbrecht

We describe techniques for creating long-lived magneto-optical and magnetostatic traps for neutral atoms. These traps exist in a sealed cryogenic environment with a temperature near 4 K, where the background gas pressure can be extremely low. To date we have observed cesium magneto-optical traps with background-limited lifetimes in excess of 1 h, and magnetostatic traps with lifetimes of nearly 10 min. From these observations we use the known He-Cs van der Waals collision cross section to infer typical background gas pressures in our apparatus below 4\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}12}$ Torr. With hardware improvements we expect this pressure can be made much lower, extending the magnetostatic-trap lifetimes one to two orders of magnitude. Furthermore, with a cryogenic system one can use superconducting magnets and SQUID detectors to trap and to nondestructively sense spin-polarized atoms. With superconducting microstructures one can achieve very large magnetic-field gradients and curvatures, as high as \ensuremath{\sim}${10}^{6}$ G/cm and \ensuremath{\sim}${10}^{9}$ G/${\mathrm{cm}}^{2}$, respectively, for use in magnetic and magneto-optical traps.

Physical Review A•Feb 1, 1995•45 citations
PENeLOPE (Precision Experiment on the Neutron Lifetime Operating with Proton Extraction) is a novel experiment to measure the lifetime of the free neutron. It features magneto-gravitational storage of ultra-cold neutrons; only one spin state of the neutrons can be stored magnetically, hence a polarization system is necessary. In contrast to most other magnetic storage experiments, the magnetic field is ramped up from zero after filling, which results in a complete spatial and energetic separation of the two spin states; this allows the use of novel techniques in cleaning the trap from the unwanted spin state in addition to pre-polarization. A polarization of 99.98% should be achievable.
A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.
Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.
We investigate the loss of Ultra-Cold Neutrons (UCN) in a magneto-gravitational trap due to microphonic vibrations. The presence of vibrations may cause the spectrum of trapped UCN to shift to an energy higher than the potential energy of the trap, and UCN may therefore escape the trap on a time scale similar to the neutron β decay lifetime of ~ 881 s. For the geometry of the UCN τ trap at Los Alamos National Laboratory (LANL), we present a simplified model of the trap in the presence of vibrations, and observe the magnitude of energy transfers that are imparted on the UCN. From this, we estimate the frequency and amplitude of vibrations that may cause the loss of 10 −4 of the neutrons over a storage time of 1000 s. We use an accelerometer to measure the frequency and amplitude of microphonic vibrations in the UCN experimental area at LANL, and find them to be similar to those used in the model. Potential implications and future work are discussed.
Magneto-Optical Traps (MOTs) have long been used to produce samples of cold trapped neutral atoms, which can be used in the measurement of a variety of physical quantities and theories. Until recently, one limitation of this type of trap was the necessity for the presence of a relatively large magnetic field which would decay only slowly after the trapping mechanism was turned off. This residual magnetic field is expected to partially destroy any atomic polarization induced, for example, by optical pumping. As a result, the precision of any physical measurement which requires polarization is limited. We will discuss the construction of our version of a newer type of MOT, the AC-MOT [2], which is designed specifically so as to minimize residual magnetic fields. We have found that our AC-MOT has lifetimes and cloud sizes similar to those we measured in our DC-MOT. We intend to use a trap similar to this in upcoming nuclear beta decay parity-violation measurements. We also discuss the numerical evolution of the optical Bloch equations in the presence of transverse and longitudinal magnetic fields, so as to quantify the effect of a magnetic field on atomic polarization.
We describe techniques for creating long-lived magneto-optical and magnetostatic traps for neutral atoms. These traps exist in a sealed cryogenic environment with a temperature near 4 K, where the background gas pressure can be extremely low. To date we have observed cesium magneto-optical traps with background-limited lifetimes in excess of 1 h, and magnetostatic traps with lifetimes of nearly 10 min. From these observations we use the known He-Cs van der Waals collision cross section to infer typical background gas pressures in our apparatus below 4\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}12}$ Torr. With hardware improvements we expect this pressure can be made much lower, extending the magnetostatic-trap lifetimes one to two orders of magnitude. Furthermore, with a cryogenic system one can use superconducting magnets and SQUID detectors to trap and to nondestructively sense spin-polarized atoms. With superconducting microstructures one can achieve very large magnetic-field gradients and curvatures, as high as \ensuremath{\sim}106{10}^{6}106 G/cm and \ensuremath{\sim}109{10}^{9}109 G/cm2{\mathrm{cm}}^{2}cm2, respectively, for use in magnetic and magneto-optical traps.