Chinese Physics B

Cooling of rubidium atoms in pulsed diffuse laser light

Hua-Dong Cheng, Xucheng Wang, Ling Xiao, Wenzhuo Zhang, Liang Liu, Yuzhu Wang

Published Feb 1, 2011• 8 citations
Publisher

Abstract

This paper reports an experiment on laser cooling of 87 Rb atoms in pulsed diffuse light, which is the key step towards a compact cold atom clock. It deduces an empirical formula to simulate the pulse cooling process based on the loading of cold atoms in cooling time and the loss in the dead time, which is in agreement with the experimental data. The formula gives a reference to select the parameters for the cold atom clock.

DOI
10.1088/1674-1056/20/2/023701

Related papers

Enhanced cooling of rubidium atoms in two-frequency diffuse lights

Wenzhuo Zhang, Hua-Dong Cheng, Ling Xiao +2 more

In this paper we describe an experiment of efficient cooling of $^{87}$Rb atoms in two-frequency diffuse laser lights. Compared with single frequency diffuse light, two-frequency diffuse lights have wider velocity capture range and thus can cool more atoms. In our experiment, the maximum number of cooled atoms can reach up to $3.9\times10^9$. Such a result is quite useful in building a compact cold atom clock.

arXiv:0901.1707•Jan 13, 2009•0 citations

Laser cooling of rubidium atoms from background vapor in diffuse light

Hua-Dong Cheng, Wenzhuo Zhang, Hongyu Ma +2 more

In this paper we describe an experiment on laser cooling of $^{87}\mathrm{Rb}$ atoms directly from a vapor background in diffuse light. Diffuse light is produced in a ceramic integrating sphere by multiple scattering of two laser beams injected through multimode fibers. A probe beam, whose propagation direction is either horizontal or vertical, is used to detect cold atoms. We measured the absorption spectra of the cold atoms by scanning the frequency of the probe beam, and observed both the absorption signal and the time of flight signal after we switched off the cooling light, from which we estimated the temperature and the number of cold atoms. This method is clearly attractive for building a compact cold atom clock.

Physical Review A•Feb 5, 2009•39 citations

Diffuse laser cooling based on the 6 P 3 / 2 excited state of rubidium atoms via 420 nm blue light

Jia Zhang, Xun Gao, Zheng Xiao +5 more

To date, the laser cooling of rubidium atoms has inevitably relied on 780 nm cooling light corresponding to the first excited state 5 P 3 / 2 . Here, we demonstrate diffuse laser cooling of Rb 87 atoms using the 420 nm 5 S 1 / 2 → 6 P 3 / 2 transition without a preceding 780 nm cooling stage. A high-power 420 nm laser is used as the cooling light to produce cold atoms in a 1-m-long diffuse-cooling cell. Absorption spectroscopy yields a cold-atom density of approximately 1.4 × 10 11 m − 3 . We compare the cooling performance of the 420 nm and conventional 780 nm diffuse-cooling schemes and verify the feasibility of using the high-excited-state transition as an independent cooling channel in this large-volume diffuse-cooling system. This approach provides an alternative cooling/pumping pathway for continuous cold-atom active optical clocks, where compatibility with the clock-lasing process and reduced cooling-light-induced perturbations are important. It is also expected to open up research directions and application prospects in frontier fields such as Rydberg atoms, quantum information, and so on.

arXiv:2511.16220•Physical Review Research•Aug 18, 2026•2 citations

Loading of cold87Rb atom with diffuse light in an integrating sphere

肖玲 Ling Xiao, 王旭成 Xucheng Wang, 张文卓 Wenzhuo Zhang +3 more

Cold 87 Rb atom's loading in an integrating sphere with diffuse light is analyzed theoretically and experimentally.The experimental results show that diffuse light cooling has the greatest efficiency to cool the most atoms when the red detuning between the frequencies of cooling light and atom transition is about 3.3Γ (Γ is the natural linewidth, 6.065 MHz).Theoretical analysis using rate equation and numerical calculations on the cold atom number and loading time agree with the experimental results.This integrating sphere cooling would be a novel method for cooling atoms and lead to a new and robust cold atom source for atomic clock.

Chinese Optics Letters•Jan 1, 2010•7 citations

Scheme for a compact cold-atom clock based on diffuse laser cooling in a cylindrical cavity

Peng Liu, Yan-Ling Meng, Jinyin Wan +5 more

We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of $24.5$ Hz with a contrast of $95.6%$ when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.

arXiv:1509.07650•Physical Review A•Dec 3, 2015•42 citations

Laser cooling of rubidium 85 atoms in integrating sphere

Xucheng Wang Xucheng Wang, Hua-Dong Cheng, Ling Xiao +4 more

We cool 85 Rb atoms in an integrating sphere directly from a vapor background using diffuse light generated by multiple reflections of laser beams in the inner surface of the integrating sphere.We compare and analyze the different features of cold 85 Rb atoms and cold 87 Rb atoms in diffuse light cooling, which are important in applying 85 Rb and 87 Rb isotopes in many experiments on testing fundamental physics.

Chinese Optics Letters•Jan 1, 2012•7 citations
This paper reports an experiment on laser cooling of 87 Rb atoms in pulsed diffuse light, which is the key step towards a compact cold atom clock. It deduces an empirical formula to simulate the pulse cooling process based on the loading of cold atoms in cooling time and the loss in the dead time, which is in agreement with the experimental data. The formula gives a reference to select the parameters for the cold atom clock.
In this paper we describe an experiment of efficient cooling of 87^{87}87Rb atoms in two-frequency diffuse laser lights. Compared with single frequency diffuse light, two-frequency diffuse lights have wider velocity capture range and thus can cool more atoms. In our experiment, the maximum number of cooled atoms can reach up to 3.9×1093.9\times10^93.9×109. Such a result is quite useful in building a compact cold atom clock.
In this paper we describe an experiment on laser cooling of 87Rb^{87}\mathrm{Rb}87Rb atoms directly from a vapor background in diffuse light. Diffuse light is produced in a ceramic integrating sphere by multiple scattering of two laser beams injected through multimode fibers. A probe beam, whose propagation direction is either horizontal or vertical, is used to detect cold atoms. We measured the absorption spectra of the cold atoms by scanning the frequency of the probe beam, and observed both the absorption signal and the time of flight signal after we switched off the cooling light, from which we estimated the temperature and the number of cold atoms. This method is clearly attractive for building a compact cold atom clock.
To date, the laser cooling of rubidium atoms has inevitably relied on 780 nm cooling light corresponding to the first excited state 5 P 3 / 2 . Here, we demonstrate diffuse laser cooling of Rb 87 atoms using the 420 nm 5 S 1 / 2 → 6 P 3 / 2 transition without a preceding 780 nm cooling stage. A high-power 420 nm laser is used as the cooling light to produce cold atoms in a 1-m-long diffuse-cooling cell. Absorption spectroscopy yields a cold-atom density of approximately 1.4 × 10 11 m − 3 . We compare the cooling performance of the 420 nm and conventional 780 nm diffuse-cooling schemes and verify the feasibility of using the high-excited-state transition as an independent cooling channel in this large-volume diffuse-cooling system. This approach provides an alternative cooling/pumping pathway for continuous cold-atom active optical clocks, where compatibility with the clock-lasing process and reduced cooling-light-induced perturbations are important. It is also expected to open up research directions and application prospects in frontier fields such as Rydberg atoms, quantum information, and so on.
Cold 87 Rb atom's loading in an integrating sphere with diffuse light is analyzed theoretically and experimentally.The experimental results show that diffuse light cooling has the greatest efficiency to cool the most atoms when the red detuning between the frequencies of cooling light and atom transition is about 3.3Γ (Γ is the natural linewidth, 6.065 MHz).Theoretical analysis using rate equation and numerical calculations on the cold atom number and loading time agree with the experimental results.This integrating sphere cooling would be a novel method for cooling atoms and lead to a new and robust cold atom source for atomic clock.
We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of 24.524.524.5 Hz with a contrast of 95.695.6%95.6 when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.