Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Progress Toward a Two-Photon Optical Atomic Clock in Neutral Silver

David McKenna, Carol E. Tanner

Published Jun 6, 2012• 0 citations
OpenAlex

Related papers

Toward a Portable Optical Atomic Clock in Neutral Silver (Ag)

Carol E. Tanner

Bulletin of the American Physical Society•Jun 16, 2011•0 citations

Progress toward a Sr optical atomic clock in an optical lattice

Andrew D. Ludlow, T. Ido, Martin M. Boyd +5 more

Bulletin of the American Physical Society•May 18, 2005•0 citations

Optical atomic clocks based on ultracold neutral strontium atoms

T. Ido, Martin M. Boyd, Andrew D. Ludlow +5 more

Conference on Lasers and Electro-Optics•Jan 1, 2005•0 citations

Progress toward a spin squeezed optical atomic clock beyond the standard quantum limit

Boris Braverman, Akio Kawasaki, Vladan Vuletić

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

Progress towards optical frequency standards based on two-photon transitions in atomic silver

Mark D. Plimmer, Thomas Badr, Stéphane Guérandel +8 more

We report advances towards the development of frequency standards based on narrow two-photon transitions in the silver atom at 576 and 661 nm from the ground 4d105s2S1/2 state to the 2D3/2,5/2 levels of the configuration 4d95s2. We describe detection schemes for metastable atoms, localisation of the position of the metastable 2D5/2 level and diode-pumped Nd:YLF lasers around 1.3 μm destined to replace dye lasers for both cooling and spectroscopy of the clock transition. Our result for the position of the 2D5/2 level is more than a factor of two improvement over previous vales.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 21, 2004•1 citation

Progress Towards the Development of a Portable All-optical Atomic Clock Based on a Two-photon Transition in Warm Atomic Vapor

S. Jana, B. K. Sahoo, Arijit Sharma

Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.

URSI Regional Conference on Radio Science (URSI-RCRS)•Dec 1, 2022•1 citation
We report advances towards the development of frequency standards based on narrow two-photon transitions in the silver atom at 576 and 661 nm from the ground 4d105s2S1/2 state to the 2D3/2,5/2 levels of the configuration 4d95s2. We describe detection schemes for metastable atoms, localisation of the position of the metastable 2D5/2 level and diode-pumped Nd:YLF lasers around 1.3 μm destined to replace dye lasers for both cooling and spectroscopy of the clock transition. Our result for the position of the 2D5/2 level is more than a factor of two improvement over previous vales.
Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.