Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Progress towards optical frequency standards based on two-photon transitions in atomic silver

Mark D. Plimmer, Thomas Badr, Stéphane Guérandel, Yann Louyer, S. CHALLEMEL DU ROZIER, P. Juncar, M. Himbert, Joshua D. Silver, F. Biraben, F. Nez, G. Hagel

Published Jun 21, 2004• 1 citation
Publisher

Abstract

We report advances towards the development of frequency standards based on narrow two-photon transitions in the silver atom at 576 and 661 nm from the ground 4d105s2S1/2 state to the 2D3/2,5/2 levels of the configuration 4d95s2. We describe detection schemes for metastable atoms, localisation of the position of the metastable 2D5/2 level and diode-pumped Nd:YLF lasers around 1.3 μm destined to replace dye lasers for both cooling and spectroscopy of the clock transition. Our result for the position of the 2D5/2 level is more than a factor of two improvement over previous vales.

DOI
10.1117/12.566996

Related papers

A 780 nm optical frequency standard based on diffuse laser cooled 87Rb atoms

Xiaolei Guan, Jia Zhang, Xun Gao +3 more

We demonstrate an optical frequency standard by locking the output frequency of an external cavity diode laser to the 780 nm D2 transition of diffuse laser cooled 87Rb atoms using frequency modulation spectroscopy (FMS). A 50-cm-long cold atomic cloud is obtained within a ϕ 2 cm ×l 50 cm vacuum glass tube, featuring greater simplicity and reliability. By analyzing the impact of power and detuning of cooling and repumping lasers, and power of frequency-modulated laser on FMS based on cold atoms, we choose the optimal parameter and lock the laser frequency to the 87Rb 52S1/2 (F = 2) → 52P3/2 (F′ = 3) cycling transition. The cold-atom-based optical frequency standard achieves an in-loop frequency stability of 3.3 × 10−15 at 1 s, with peak-to-peak frequency fluctuations being less than 50 Hz within 6000 s. This represents the integration of cold atoms into an optical frequency standard utilizing FMS for frequency stabilization. In contrast to the common cold-atom optical frequency standards, our approach requires fewer lasers and eliminates the need for a complex and expensive Pound–Drever–Hall (PDH) system. Its low complexity makes it a promising candidate for development into a space cold-atom clock, promoting advancements in space science and navigational positioning. Additionally, it possesses great potential to serve as an absolute wavelength standard.

Applied Physics Letters•Jan 20, 2025•12 citations

Progress in the development of an optical frequency standard at 192.6 THz based on a two-photon transition of rubidium atoms at Laval University

Christine Latrasse, M. Poulin, Driss Touahri +2 more

We have developed frequency standards at 192.6 THz (1556.2 nm) based on the two-photon transitions in rubidium at 385.2 THz (778.1 nm). These standards use a high power DFB laser at 1556.2 nm and second harmonic generation (SHG) in a periodically poled lithium niobate (PPLN) crystal. The linewidth of the DFB is reduced to the kHz level using optical feedback from a confocal cavity. The SH light is used to injection-lock a 778.1 nm laser diode which allows to observe and lock the 1556.2 nm laser to the (5S/sub 1/2/,F/sub g/=2-5D/sub 5/2/,F/sub e/=4) two-photon transition /sup 87/Rb. Allan variance measurements between identical standards show a beat stability 2.5/spl times/10/sup -13///spl tau//sup 1/2/ for observation times between 100 ms and 10 s and a level of 5.8/spl times/10/sup -14/ for 100 s is obtained. These standards have been moved recently to the National Research Council, Ottawa, Canada in order to measure their absolute frequency.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation

Compact frequency standard at 1556 nm based on the two-photon transition in rubidium at 778 nm

Michel Poulin, Christine Latrasse, Driss Touahri +2 more

This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 1998•0 citations

Research progress on active optical clocks

Jingbiao Chen, Wei Zhang

Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.

Chinese Science Bulletin (Chinese Version)•Jul 1, 2015•3 citations

Narrow-linewidth Brillouin laser for a two-photon rubidium frequency standard

Anonymous, River Beard, Andrei Isichenko +5 more

High-precision, portable, and deployable frequency standards are required for modern navigation and communication technologies. Optical frequency standards are attractive for their improved stability over their microwave counterparts; however, increased complexities have anchored them in the laboratory. Sacrificing the sensitivity of the most stable optical clocks has led to the recent development of deployable and portable optical frequency standards, leveraging hot atomic or molecular vapor. The short-term limit for a majority of previous reports on two-photon rubidium standards is either the shot-noise or intermodulation limit hindering the 1 s fractional frequency stability to around 1 × 10 − 13 . The answer for the shot-noise limit is to increase optical power and collected fluorescence, while the intermodulation limit solution requires improvements in laser linewidth, stimulated Brillouin scattering (SBS) lasers are known to reduce frequency noise, suppressing noise of the pump laser. We investigate an optical frequency standard based on the two-photon transition in Rb 87 probed with a narrow photonic integrated circuit SBS laser with a quality factor over 130 million and instantaneous linewidth < 10 Hz . The use of a narrow clock laser coupled with operating at higher optical intensities yielded clock instabilities of 2 × 10 − 14 at 1 s, currently the best reported short-term stability for a two-photon rubidium optical frequency standard.

arXiv:2602.09364•Physical Review Applied•Jul 14, 2026•0 citations

Two-photon two-color diode laser spectroscopy of the Rb 5D5/2state

Timothy T. Grove, V. Sánchez-Villicaña, B C Duncan +2 more

We report on spectroscopic measurements of the Rb 5 D 5/2 state performed using two-photon excitation with a resonant intermediate state. With the two beams (5 S 1/2 → 5 P 3/2 at 780 nm and 5 P 3/2 → 5 D 5/2 at 776 nm) counterpropagating, the spectra are Doppler-free and the signals are very robust, even in a room temperature vapor. This is due to the near match of the transition wavelengths. The 5 D 5/2 hyperfine constants have been measured and compared to previous determinations. We have also performed the excitation in a sample of laser-cooled atoms and compare these results to those obtained at room temperature. The fact that the 5 P 3/2 → 5 D 5/2 transition is narrow, robust, diode-laser accessible, and relatively immune to AC-Stark shifts, may make it a promising candidate for a frequency reference at 776 nm.

Physica Scripta•Sep 1, 1995•74 citations
We report advances towards the development of frequency standards based on narrow two-photon transitions in the silver atom at 576 and 661 nm from the ground 4d105s2S1/2 state to the 2D3/2,5/2 levels of the configuration 4d95s2. We describe detection schemes for metastable atoms, localisation of the position of the metastable 2D5/2 level and diode-pumped Nd:YLF lasers around 1.3 μm destined to replace dye lasers for both cooling and spectroscopy of the clock transition. Our result for the position of the 2D5/2 level is more than a factor of two improvement over previous vales.
We demonstrate an optical frequency standard by locking the output frequency of an external cavity diode laser to the 780 nm D2 transition of diffuse laser cooled 87Rb atoms using frequency modulation spectroscopy (FMS). A 50-cm-long cold atomic cloud is obtained within a ϕ 2 cm ×l 50 cm vacuum glass tube, featuring greater simplicity and reliability. By analyzing the impact of power and detuning of cooling and repumping lasers, and power of frequency-modulated laser on FMS based on cold atoms, we choose the optimal parameter and lock the laser frequency to the 87Rb 52S1/2 (F = 2) → 52P3/2 (F′ = 3) cycling transition. The cold-atom-based optical frequency standard achieves an in-loop frequency stability of 3.3 × 10−15 at 1 s, with peak-to-peak frequency fluctuations being less than 50 Hz within 6000 s. This represents the integration of cold atoms into an optical frequency standard utilizing FMS for frequency stabilization. In contrast to the common cold-atom optical frequency standards, our approach requires fewer lasers and eliminates the need for a complex and expensive Pound–Drever–Hall (PDH) system. Its low complexity makes it a promising candidate for development into a space cold-atom clock, promoting advancements in space science and navigational positioning. Additionally, it possesses great potential to serve as an absolute wavelength standard.
We have developed frequency standards at 192.6 THz (1556.2 nm) based on the two-photon transitions in rubidium at 385.2 THz (778.1 nm). These standards use a high power DFB laser at 1556.2 nm and second harmonic generation (SHG) in a periodically poled lithium niobate (PPLN) crystal. The linewidth of the DFB is reduced to the kHz level using optical feedback from a confocal cavity. The SH light is used to injection-lock a 778.1 nm laser diode which allows to observe and lock the 1556.2 nm laser to the (5S/sub 1/2/,F/sub g/=2-5D/sub 5/2/,F/sub e/=4) two-photon transition /sup 87/Rb. Allan variance measurements between identical standards show a beat stability 2.5/spl times/10/sup -13///spl tau//sup 1/2/ for observation times between 100 ms and 10 s and a level of 5.8/spl times/10/sup -14/ for 100 s is obtained. These standards have been moved recently to the National Research Council, Ottawa, Canada in order to measure their absolute frequency.
This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.
Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.
High-precision, portable, and deployable frequency standards are required for modern navigation and communication technologies. Optical frequency standards are attractive for their improved stability over their microwave counterparts; however, increased complexities have anchored them in the laboratory. Sacrificing the sensitivity of the most stable optical clocks has led to the recent development of deployable and portable optical frequency standards, leveraging hot atomic or molecular vapor. The short-term limit for a majority of previous reports on two-photon rubidium standards is either the shot-noise or intermodulation limit hindering the 1 s fractional frequency stability to around 1 × 10 − 13 . The answer for the shot-noise limit is to increase optical power and collected fluorescence, while the intermodulation limit solution requires improvements in laser linewidth, stimulated Brillouin scattering (SBS) lasers are known to reduce frequency noise, suppressing noise of the pump laser. We investigate an optical frequency standard based on the two-photon transition in Rb 87 probed with a narrow photonic integrated circuit SBS laser with a quality factor over 130 million and instantaneous linewidth < 10 Hz . The use of a narrow clock laser coupled with operating at higher optical intensities yielded clock instabilities of 2 × 10 − 14 at 1 s, currently the best reported short-term stability for a two-photon rubidium optical frequency standard.
We report on spectroscopic measurements of the Rb 5 D 5/2 state performed using two-photon excitation with a resonant intermediate state. With the two beams (5 S 1/2 → 5 P 3/2 at 780 nm and 5 P 3/2 → 5 D 5/2 at 776 nm) counterpropagating, the spectra are Doppler-free and the signals are very robust, even in a room temperature vapor. This is due to the near match of the transition wavelengths. The 5 D 5/2 hyperfine constants have been measured and compared to previous determinations. We have also performed the excitation in a sample of laser-cooled atoms and compare these results to those obtained at room temperature. The fact that the 5 P 3/2 → 5 D 5/2 transition is narrow, robust, diode-laser accessible, and relatively immune to AC-Stark shifts, may make it a promising candidate for a frequency reference at 776 nm.