Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Performance of a prototype microwave frequency standard based on trapped /sup 171/Yb/sup +/ ions

Peter Fisk, Matthew J. Sellars, M.A. Lawn, C. Coles, Anthony G. Mann, D. G. Blair

Published Dec 17, 2002• 5 citations
Publisher

Abstract

A microwave frequency standard based on buffer-gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap has been demonstrated in prototype form. The standard exhibits a fractional Allan deviation /spl sigma//sub y/(/spl tau/)=3.7/spl times/10/sup -13/ /spl tau//sup -1/2/ for /spl tau/>
DOI
10.1109/freq.1994.398255

Related papers

Very high Q microwave spectroscopy on trapped /sup 171/Yb/sup +/ ions: application as a frequency standard

Peter Fisk, Matthew J. Sellars, M.A. Lawn +3 more

A microwave frequency standard based on buffer-gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap has been demonstrated in prototype form. The standard exhibits a fractional frequency instability characterized by an Allan deviation /spl sigma//sub y/(/spl tau/)=3.7/spl times/10/sup -13//spl tau//sup -1/2/ for /spl tau/>

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1995•46 citations

Very-high Q microwave resonances in trapped /sup 171/Yb/sup +/ ions: application as a microwave frequency standard

Peter Fisk, M.A. Lawn, C. Coles +2 more

The 12.6 GHz microwave resonance in /sup 171/Yb/sup +/ ions confined in a linear Paul trap is interrogated using a cryogenic sapphire resonator-based microwave source. Line Q factors of up to 1.1/spl times/10/sup 13/ have been observed. We report on the performance of the ion trap-sapphire resonator system as a prototype 12.6 GHz frequency standard.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•0 citations

A microwave frequency standard based on laser-cooled /sup 171/Yb/sup +/ ions

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled /sup 171/Yb/sup +/ ions. The projected performance of this standard (frequency uncertainty /spl les/ 4 /spl times/ 10/sup -15/ and stability 5 /spl times/ 10/sup -14/ /spl tau//sup -1/2/ for a 10 s Ramsey time) is comparable to that of a cesium fountain.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•0 citations

Progress at CSIRO Australia towards a microwave frequency standard based on trapped, laser-cooled /sup 171/Yb/sup +/ ions

Peter Fisk, M.A. Lawn, C. Coles

The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•1 citation

Optical frequency standard investigations on trapped /sup 171/Yb/sup +/

Chr. Tamm, D. Engelke

Summary form only given, as follows.Single /sup 171/Yb ions are laser cooled in a Paul trap, using laser sources based on semiconductor diode lasers. Excitation of the potential frequency-standard reference transition to the /sup 2/D/sub 3/2/, (F=2) hyperfine sublevel of /sup 171/Yb/sup +/ at a wavelength of 435.5 nm is demonstrated.

Conference on Precision Electromagnetic Measurements•Dec 24, 2002•0 citations

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.

Symposium on Frequency Standards and Metrology•May 1, 2002•11 citations
The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>
We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.