Conference on Precision Electromagnetic Measurements

Improving the Accuracy of the CA Optical Frequency Standard

Chris W. Oates, G. Wilpers, E. A. Curtis, Leo W. Hollberg

Published Jun 1, 2004• 0 citations
Publisher

Abstract

We demonstrate the reduction of residual Doppler shifts for a laser-cooled neutral atom optical frequency standard to near negligible levels through use of second-stage laser cooling and atom interferometry. For the NIST Ca optical clock, this opens up the possibility for uncertainties of less than 1 part in 1016
DOI
10.1109/cpem.2004.305590

Related papers

Ultracold atoms and precise time standards

Gretchen K. Campbell, William D. Phillips

Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Sep 19, 2011•31 citations

Optical Clock with Ultracold Neutral Atoms

G. Wilpers, T. Binnewies, C. Degenhardt +3 more

We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard, we show how to reduce the relative uncertainty to below 10(-15). We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.36, which is 70% of the ultimate limit achievable with atoms at rest. A novel scheme was applied to detect these atom interferences with the prospect to reach the quantum projection noise limit at an exceptional low instability of 4 x 10(-17) in 1 s.

arXiv:physics/0205049•Physical Review Letters•Nov 15, 2002•146 citations

Calcium optical frequency standard

F. Riehle, H. Schnatz, B. Lipphardt +5 more

A laser that is frequency stabilized to the intercombination transition at (lambda) equals 657 nm of laser cooled 40Ca atoms by means of time-domain atom interferences has been developed at PTB. The relative uncertainty of this optical frequency standard is 2.5 X 10-13 and the frequency of the laser has been measured with both, a conventional frequency measurement chain and a femtosecond laser. To reduce the uncertainty of this standard the dependence of its frequency on various parameters was investigated by using phase sensitive and frequency sensitive atom interferometers. Upper bounds were derived for various contributions to the uncertainty as e.g. the influence of gravitational acceleration, collisions of the ballistic atoms, or curvature of the wave fronts of the interrogating laser beams. Further reduction of the uncertainty of the standard is expected from the application of sub-Doppler cooling techniques. A method was devised based on the narrow intercombination transition that enabled us to reduce the velocity spread of the Ca atoms in one dimension close to the recoil limit. The method uses the repeated selection and accumulation of slow atoms from the pre-cooled atomic cloud and the repeated rethermalization of the remaining atoms and results in an increased visibility of the interference structure.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•1 citation

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations

Atom interferometric method for eliminating Doppler effects in precision measurements

G. Wilpers, Chris W. Oates, Leo W. Hollberg

Abstract: We present a method to reduce the residual Doppler effect by almost two orders of magnitude in our optical frequency standard. The approach combines atom interferometry and launching of microkelvin neutral atoms.

Conference on Lasers and Electro-Optics•May 16, 2004•0 citations

Development of an atomic frequency standard in the optical domain based on ultracold Ytterbium atoms

Marco Zoppi

The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage

•Jan 1, 2012•0 citations
Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.
We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard, we show how to reduce the relative uncertainty to below 10(-15). We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.36, which is 70% of the ultimate limit achievable with atoms at rest. A novel scheme was applied to detect these atom interferences with the prospect to reach the quantum projection noise limit at an exceptional low instability of 4 x 10(-17) in 1 s.
A laser that is frequency stabilized to the intercombination transition at (lambda) equals 657 nm of laser cooled 40Ca atoms by means of time-domain atom interferences has been developed at PTB. The relative uncertainty of this optical frequency standard is 2.5 X 10-13 and the frequency of the laser has been measured with both, a conventional frequency measurement chain and a femtosecond laser. To reduce the uncertainty of this standard the dependence of its frequency on various parameters was investigated by using phase sensitive and frequency sensitive atom interferometers. Upper bounds were derived for various contributions to the uncertainty as e.g. the influence of gravitational acceleration, collisions of the ballistic atoms, or curvature of the wave fronts of the interrogating laser beams. Further reduction of the uncertainty of the standard is expected from the application of sub-Doppler cooling techniques. A method was devised based on the narrow intercombination transition that enabled us to reduce the velocity spread of the Ca atoms in one dimension close to the recoil limit. The method uses the repeated selection and accumulation of slow atoms from the pre-cooled atomic cloud and the repeated rethermalization of the remaining atoms and results in an increased visibility of the interference structure.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.
The work described in this thesis was done at the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), in the optic division, within the Ph.D. of Metrology of the Politecnico di Torino. My work consisted in developing a new generation optical frequency standard based on Ytterbium atoms: the goal of this project is to realize a clock whose performance overcomes the ones of the standard which actually realizes the Second, the atomic Cesium fountain. This means realizes an apparatus which shows stability and accuracy better then the fountain ones: a possible way adopted in several new generation clock is using optical transitions, because they offer an higher quality factor of the clock transition itself, which means a better stability and the possibility to reach the 10^-17 level in the global accuracy of the clock. The fundamental idea of a clock is to realize as close as possible the basic idea under the actual definition of the Second, that is to fix the unit if time with a particular atomic transition, when the atom is completely unperturbed. Accomplishing this prescription means a lot of work in cooling down the atoms until the 10^-6 K regime using laser cooling techniques, developing a trap where atoms can be excited by the clock laser (the optical lattice) and of course a very careful frequency and amplitude stabilization of the clock laser itself is needed to reach our goal. The work described in this thesis regards the development of the two cooling stages of the Yb atoms and it is presented as follows. Chapter 1 explains with more details why an optical clock is needed to improve the accuracy of the actual realization of the Second, then describing the theoretical framework in which the clock will be developed. Chapter 2 contains a description of the experimental apparatus used, with more attention on the instrumentation related to the laser cooling of the atoms. Chapter 3 is about the characterization of the first cooling stage, both in a static and in a dynamic way, with some attention on the theoretical model developed to perform both the characterizations. Chapter 4 focuses on the development of the second cooling stage and it describes the actual state of the art of this stage