Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Proposed Active Optical Frequency Standards based on Magneto-optical Trap Trapped Atoms

Wei Zhuang, Deshui Yu, Zhenhui Chen, Kaikai Huang, Jingbiao Chen

Published May 1, 2007• 9 citations
Publisher

Abstract

A new conception of optical frequency standards, active optical frequency standards (AOFS) is under developing. In this report, we propose a novel scheme for active optical frequency standards based on magneto-optical trap (MOT) trapped atoms. With the advantages of 4-level atomic system proposed here, this scheme overcomes the main limitations on the accuracy of active optical clock based on atomic beam due to Doppler effect.

DOI
10.1109/freq.2007.4319039

Related papers

Research progress on active optical clocks

Jingbiao Chen, Wei Zhang

Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.

Chinese Science Bulletin (Chinese Version)•Jul 1, 2015•3 citations

Different ways to active optical frequency standards

Duo Pan, Xiaobo Xue, Xiaogang Zhang +1 more

Active optical frequency standard, or active optical clock, is a new concept of optical frequency standard, where a weak feedback with phase coherence information in optical bad-cavity limitation is formed, and the continuous self-sustained coherent stimulated emission between two atomic transition levels with population inversion is realized. Through ten years of both theoretical and experimental exploration, the narrow linewidth and suppression of cavity pulling effect of active optical frequency standard have been initially proved. In this paper, after a simple review, we will mainly present the most recent experimental progresses of active optical frequency standards in Peking University, including 4-level cesium active optical frequency standards and active Faraday optical frequency standards. The future development of active optical frequency standards is also discussed.

Journal of Physics Conference Series•Jun 1, 2016•1 citation

Cesium-133 magneto-optical trap at CENAM

J.M. Romero-Lopez, I. Lopez-Dominguez, E.L. De Carlos +1 more

With the aim of developing a cold cesium atom primary frequency standard, a cesium-133 magneto-optical trap (MOT) has been developed at CENAM's Time and Frequency Division. In this paper we present and discuss the main components of the MOT: the optical, vacuum, and mechanical systems.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•2 citations

Progress of Active Optical Frequency Standard based on thermal Ca atomic beam

Wei Zhuang, Jingbiao Chen

The experiment system for Active Optical Frequency Standard(AOFS) based on thermal Ca atomic beam has been set up. Making use of magnetic field for the atomic beam, we have realized population inversion between ground state1S0and metastable state3P1(m=0) which is primary for AOFS. Detection results are presented by applying electron-shelving technique on thermal Ca atomic beam.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•7 citations

A frequency standard based on a continuous beam of laser cooled atoms

P. Berthoud, Alain Joyet, P. Thomann +1 more

A frequency standard based on a continuous beam of laser cooled atoms as an alternative to a pulsed scheme of an atomic fountain is currently investigated. A general overview of such a device and its main parts are presented. Two mechanisms of continuous extraction of atoms from an anisotropic magneto-optical trap are experimentally demonstrated. Stability and accuracy issues are discussed.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•0 citations

A clock transition for future optical frequency standard with trapped atoms

Irène Ventrillard, Audrey Quessada, Anders Brusch +7 more

Direct observation and frequency measurement of /sup 1/S/sub 0//spl rarr//sup 3/P/sub 0 /line within an accuracy of 20 kHz is reported. The resonance frequency with an accuracy of /spl sim/ 100 kHz is reported by indirect measurement of the energy difference between /sup 1/S/sub 0/ and /sup 3/P/sub 0/ states. It is performed by successive frequency measurements of atomic transitions with higher linewidth, easier to observe: /sup 1/S/sub 0/ - /sup 3/P/sub 1/, /sup 3/P/sub 1/ - /sup 3/S/sub 1/ and /sup 3/S/sub 1/ - /sup 3/P/sub 0/ transitions. To perform direct observation of the clock transition, atoms are cooled to a temperature of /spl sim/ 2 mK in a magneto-optical trap (MOT). Although the saturation broadening of the transition is orders of magnitude smaller than the Doppler width (1.5 MHz), a detectable signal is achieved by inducing a small leak in the MOT with a laser tuned to resonance. Atoms accumulate in the metastable /sup 3/P/sub 0 /state where they escape the trap. The resonance is detected by a decrease in the MOT fluorescence signal with a contrast of 1%.

European Quantum Electronics Conference (EQEC)•Jan 1, 2003•6 citations
A new conception of optical frequency standards, active optical frequency standards (AOFS) is under developing. In this report, we propose a novel scheme for active optical frequency standards based on magneto-optical trap (MOT) trapped atoms. With the advantages of 4-level atomic system proposed here, this scheme overcomes the main limitations on the accuracy of active optical clock based on atomic beam due to Doppler effect.
Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.
Active optical frequency standard, or active optical clock, is a new concept of optical frequency standard, where a weak feedback with phase coherence information in optical bad-cavity limitation is formed, and the continuous self-sustained coherent stimulated emission between two atomic transition levels with population inversion is realized. Through ten years of both theoretical and experimental exploration, the narrow linewidth and suppression of cavity pulling effect of active optical frequency standard have been initially proved. In this paper, after a simple review, we will mainly present the most recent experimental progresses of active optical frequency standards in Peking University, including 4-level cesium active optical frequency standards and active Faraday optical frequency standards. The future development of active optical frequency standards is also discussed.
Direct observation and frequency measurement of /sup 1/S/sub 0//spl rarr//sup 3/P/sub 0 /line within an accuracy of 20 kHz is reported. The resonance frequency with an accuracy of /spl sim/ 100 kHz is reported by indirect measurement of the energy difference between /sup 1/S/sub 0/ and /sup 3/P/sub 0/ states. It is performed by successive frequency measurements of atomic transitions with higher linewidth, easier to observe: /sup 1/S/sub 0/ - /sup 3/P/sub 1/, /sup 3/P/sub 1/ - /sup 3/S/sub 1/ and /sup 3/S/sub 1/ - /sup 3/P/sub 0/ transitions. To perform direct observation of the clock transition, atoms are cooled to a temperature of /spl sim/ 2 mK in a magneto-optical trap (MOT). Although the saturation broadening of the transition is orders of magnitude smaller than the Doppler width (1.5 MHz), a detectable signal is achieved by inducing a small leak in the MOT with a laser tuned to resonance. Atoms accumulate in the metastable /sup 3/P/sub 0 /state where they escape the trap. The resonance is detected by a decrease in the MOT fluorescence signal with a contrast of 1%.