Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Optimization of the Dick effect in an optical lattice clock

Philip G. Westergaard, Jérôme Lodewyck, P. Lemonde

Published Apr 1, 2009• 0 citations
Publisher

Abstract

We discuss the optimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a non-destructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 middot 10-16tau-1/2for the lattice clock.

DOI
10.1109/freq.2009.5168387

Related papers

Minimizing the dick effect in an optical lattice clock

Philip G. Westergaard, Jérôme Lodewyck, P. Lemonde

We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a nondestructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 x 10(-16tau-1/2) for the lattice clock.

arXiv:0909.0909•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2010•60 citations

The Dick effect for an optical frequency standard

Audrey Quessada, Richard P. Kovacich, I. Courtillot +3 more

We present an analysis of the frequency stability degradation of an optical atomic frequency standard which is operated sequentially, and that is caused by the frequency noise of the laser used to interrogate the clock transition. This is an extension to optical frequencies of the 'Dick effect' already studied in atomic microwave frequency standards. It is shown that the simple concept of laser linewidth is not the relevant parameter to estimate the frequency stability degradation. Rather, the details of the laser frequency noise spectral density must be accounted for together with the parameters of the interrogation method. We compute the optical Dick effect in the case of a four pulse Ramsey–Bordé interferometer. We show that it may be minimized by optimizing the time sequence so that only the Fourier frequencies with minimum laser noise are sampled. Finally, we evaluate the degradation which would be obtained with one of our lasers used as an interrogation oscillator. This laser reaches a white noise floor S ν ( f ) = 10 −2 Hz 2 /Hz at a Fourier frequency of 100 Hz. We show that with this particular laser, a relative frequency stability of the order of 10 −16 in a 1 s averaging time can be reached using realistic experimental parameters.

Journal of Optics B Quantum and Semiclassical Optics•Apr 1, 2003•107 citations

Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

Xiao-Yong Liu, Peng Liu, Jie Li +20 more

Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.

arXiv:2509.15100•Physical Review Letters•Nov 26, 2025•15 citations

Duty cycle engineering for improved optical lattice clock stability

Filip Butuc-Mayer, Matthew Johnson, Chen-Hao Feng +3 more

Abstract We describe a method of duty cycle engineering in optical lattice clocks to reduce clock instability through tailoring of the Dick effect noise contribution. We apply dynamically decoupled interrogation sequences to realise an estimated improvement in single clock instability approaching a factor of two, as well as providing a route to zero dead-time operation for two interleaved clocks which are otherwise unable to reach the required duty cycle. We show through simulations and synchronous measurements of clocks NPL-Sr1 and NPL-Sr2 that a quantum projection noise limited instability < 3 − 10−17 τ −1/2 can be realised in a near ideal zero dead-time configuration.

Journal of Physics Conference Series•Nov 1, 2024•0 citations

Dick Effect in a Microwave Frequency Standard Based on Laser-Cooled 113 Cd+ Ions

Jianwei Zhang, K. Miao, Lijun Wang

The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.

Chinese Physics Letters•Jan 1, 2015•13 citations

Contributing to TAI with Sr optical lattice clocks

Sławomir Bilicki, Eva Bookjans, Grégoire Vallet +3 more

In this paper, we present recent experiments conducted with two87Sr optical lattice clocks operated at LNE-SYRTE. We report on the first calibrations of TAI with optical clocks, a necessary step towards the redefinition of the SI second. Additionally, we report on the experimental realization of a cavity-assisted non-destructive detection whose improved signal-to-noise ratio can improve the stability of optical clocks by reducing the Dick effect instability contribution, possibly beyond the quantum projection noise. Finally, we discuss the possibility to operate lattice clocks with semi-conductor sources as a lattice trap laser, by evaluating the frequency shift induced by their incoherent background light.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•3 citations
We discuss the optimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a non-destructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 middot 10-16tau-1/2for the lattice clock.
We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a nondestructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 x 10(-16tau-1/2) for the lattice clock.
We present an analysis of the frequency stability degradation of an optical atomic frequency standard which is operated sequentially, and that is caused by the frequency noise of the laser used to interrogate the clock transition. This is an extension to optical frequencies of the 'Dick effect' already studied in atomic microwave frequency standards. It is shown that the simple concept of laser linewidth is not the relevant parameter to estimate the frequency stability degradation. Rather, the details of the laser frequency noise spectral density must be accounted for together with the parameters of the interrogation method. We compute the optical Dick effect in the case of a four pulse Ramsey–Bordé interferometer. We show that it may be minimized by optimizing the time sequence so that only the Fourier frequencies with minimum laser noise are sampled. Finally, we evaluate the degradation which would be obtained with one of our lasers used as an interrogation oscillator. This laser reaches a white noise floor S ν ( f ) = 10 −2 Hz 2 /Hz at a Fourier frequency of 100 Hz. We show that with this particular laser, a relative frequency stability of the order of 10 −16 in a 1 s averaging time can be reached using realistic experimental parameters.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
Abstract We describe a method of duty cycle engineering in optical lattice clocks to reduce clock instability through tailoring of the Dick effect noise contribution. We apply dynamically decoupled interrogation sequences to realise an estimated improvement in single clock instability approaching a factor of two, as well as providing a route to zero dead-time operation for two interleaved clocks which are otherwise unable to reach the required duty cycle. We show through simulations and synchronous measurements of clocks NPL-Sr1 and NPL-Sr2 that a quantum projection noise limited instability < 3 − 10−17 τ −1/2 can be realised in a near ideal zero dead-time configuration.
The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.
In this paper, we present recent experiments conducted with two87Sr optical lattice clocks operated at LNE-SYRTE. We report on the first calibrations of TAI with optical clocks, a necessary step towards the redefinition of the SI second. Additionally, we report on the experimental realization of a cavity-assisted non-destructive detection whose improved signal-to-noise ratio can improve the stability of optical clocks by reducing the Dick effect instability contribution, possibly beyond the quantum projection noise. Finally, we discuss the possibility to operate lattice clocks with semi-conductor sources as a lattice trap laser, by evaluating the frequency shift induced by their incoherent background light.