Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

A Superconducting Cold-Electron Bolometer with SIS’ and Josephson Tunnel Junctions

L. S. Kuzmin

Published Jan 18, 2008• 12 citations
Publisher
DOI
10.1007/s10909-007-9654-9

Related papers

Superconducting cold-electron bolometer with proximity traps

L. S. Kuzmin

Microelectronic Engineering•Jul 16, 2003•11 citations

A parallel/series array of superconducting cold-electron bolometers with SIS' tunnel junctions

L. S. Kuzmin

A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 17, 2008•3 citations

The design and instrumentation of a superconducting bolometer

Jerald Ray Hyde

•Jan 1, 2015•0 citations

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

Journal of Experimental and Theoretical Physics Letters•May 1, 2005•6 citations

High speed hot-electron superconducting bolometer

G. N. Gol'tsman

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 30, 1993•0 citations

Terahertz transmission spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, Evgueni Stepantsov +4 more

For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 8, 2004•3 citations
A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.
For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.