IEEE Transactions on Applied Superconductivity

Energy Relaxation Times in a Nb Persistent Current Qubit

Yang Yu, William D. Oliver, D. Nakada, J.C. Lee, Karl K. Berggren, Terry P. Orlando

Published Jun 1, 2005• 4 citations
Publisher

Abstract

We measured the energy relaxation time in a Nb superconducting persistent current qubit using a time-resolved fast measurement scheme. The energy relaxation time is longer than 10/spl mu/s, showing a strong potential of realizing quantum computation with Nb-based superconducting qubits.
DOI
10.1109/tasc.2005.850078

Related papers

Energy Relaxation Time between Macroscopic Quantum Levels in a Superconducting Persistent-Current Qubit

Yang Yu, D. Nakada, Janice C. Lee +5 more

We measured the intrawell energy relaxation time tau(d) approximately 24 micros between macroscopic quantum levels in the double well potential of a Nb persistent-current qubit. Interwell population transitions were generated by irradiating the qubit with microwaves. Zero population in the initial well was then observed due to a multilevel decay process in which the initial population relaxed to lower energy levels during the driven transitions. The decoherence time, estimated from tau(d) within the spin-boson model, is about 20 micros for this configuration with a Nb superconducting qubit.

arXiv:cond-mat/0311289•Physical Review Letters•Mar 18, 2004•43 citations

Methods to achieve near-millisecond energy relaxation and dephasing times for a superconducting transmon qubit

Mikko Tuokkola, Yoshiki Sunada, Heidi Kivijärvi +6 more

Abstract Superconducting qubits are one of the most promising physical systems for implementing quantum computers. However, executing quantum algorithms of practical computational advantage requires further improvements in the fidelities of qubit operations, which are currently limited by the energy relaxation and dephasing times of the qubits. Here, we report our measurement results of a high-coherence transmon qubit with energy relaxation and echo dephasing times surpassing those in the existing literature. We measure a qubit frequency of 2.9 GHz, an energy relaxation time T 1 with a median of 425 μs and a maximum of (666 ± 33)μs, and an echo dephasing time $${T}_{2}^{{{{\rm{echo}}}}}$$ T 2 echo with a median of 541 μs and a maximum of (1057 ± 138)μs. We report in detail our design, fabrication process, and measurement setup to facilitate the reproduction and wide adoption of high-coherence transmon qubits in the academia and industry.

arXiv:2407.18778•Nature Communications•Jul 8, 2025•98 citations

Multi-Photon, Multi-Level Dynamics in a Superconducting Persistent-Current Qubit

Yu, Y., William D. Oliver, J. C. Lee +3 more

Single-, two-, and three-photon transitions were driven amongst five quantum states of a niobium persistent-current qubit. A multi-level energy-band diagram was extracted using microwave spectroscopy, and avoided crossings were directly measured between the third and fourth excited states. The energy relaxation times between states connected by single-photon and multi-photon transitions were approximately 30 - 100 microseconds. Three-photon coherent oscillations were observed between the qubit ground and fourth excited states with a decoherence time of approximately 50 nanoseconds.

arXiv:cond-mat/0508587•Aug 24, 2005•6 citations

Energy Relaxation Time between Macroscopic Quantum Levels in a Superconducting Persistent-Current Qubit

D. Nakada, J. C. Lee, Yi Yu

Physical Review A•Jan 1, 2004•0 citations

Experimental Findings on the Superconducting Quantum Annealing Circuit and those Applications to a Gate-Type Quantum Computer

Daisuke Saida

The superconducting quantum annealing circuit is constructed with four Nb layers and Josephson junctions with a critical current density of 1 μA/μm2. Three key points exist to perform the quantum annealing in experiments. First, the shape of the energy potential of the qubit should be accurately designed. Second, the current pulses for modulation of the shape of the energy potential must propagate to the qubit accurately. Third is the suppression of noise in the environment where the qubit is placed. Furthermore, calibration of the measurement data is necessary with consideration of the experimental environment. In this paper, I will present a mechanism for realizing quantum annealing from two perspectives: a theoretical model and an experiment. Experimental findings on quantum annealing will contribute to study of the surrounding circuit of a gate-type quantum computer.

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)•Jul 19, 2024•0 citations

Characterization and Comparison of Energy Relaxation in Fluxonium Qubits

Kate Azar, Lamia Ateshian, Mallika T. Randeria +19 more

Fluxonium superconducting qubits have demonstrated long coherence times and high single- and two-qubit gate fidelities, making them a favorable building block for superconducting quantum processors. We investigate the dominant limitations to fluxonium qubit energy relaxation time $T_1$ using a set of eight planar, aluminum-on-silicon qubits. We find that a circuit-based model for capacitive dielectric loss best captures the frequency dependence of $T_1$, which we analyze within both a two-level and a six-level energy relaxation model. We convert the measured $T_1$ into an effective capacitive quality factor $Q_\mathrm{C}^{\mathrm{eff}}$ to compare qubits on equal footing, accounting for independently estimated contributions from $1/f$ flux noise and radiative loss to the control and readout circuitry. We apply this methodology to compare qubits from two fabrication processes: a baseline process and one that applies a fluorine-based wet treatment prior to Josephson junction deposition. We resolve a small improvement of (13.8 $\pm$ 8.4$)\%$ in the process mean $Q_\mathrm{C}^{\mathrm{eff}}$, indicating that the fluorine treatment may have reduced loss from the metal-substrate interface, but did not address the primary source of loss in these fluxonium qubits.

quant-pharXiv:2603.23636•Physical Review Research•Mar 26, 2026•8 citations
We measured the intrawell energy relaxation time tau(d) approximately 24 micros between macroscopic quantum levels in the double well potential of a Nb persistent-current qubit. Interwell population transitions were generated by irradiating the qubit with microwaves. Zero population in the initial well was then observed due to a multilevel decay process in which the initial population relaxed to lower energy levels during the driven transitions. The decoherence time, estimated from tau(d) within the spin-boson model, is about 20 micros for this configuration with a Nb superconducting qubit.
Abstract Superconducting qubits are one of the most promising physical systems for implementing quantum computers. However, executing quantum algorithms of practical computational advantage requires further improvements in the fidelities of qubit operations, which are currently limited by the energy relaxation and dephasing times of the qubits. Here, we report our measurement results of a high-coherence transmon qubit with energy relaxation and echo dephasing times surpassing those in the existing literature. We measure a qubit frequency of 2.9 GHz, an energy relaxation time T 1 with a median of 425 μs and a maximum of (666 ± 33)μs, and an echo dephasing time T2echo{T}_{2}^{{{{\rm{echo}}}}}T2echo​ T 2 echo with a median of 541 μs and a maximum of (1057 ± 138)μs. We report in detail our design, fabrication process, and measurement setup to facilitate the reproduction and wide adoption of high-coherence transmon qubits in the academia and industry.
Single-, two-, and three-photon transitions were driven amongst five quantum states of a niobium persistent-current qubit. A multi-level energy-band diagram was extracted using microwave spectroscopy, and avoided crossings were directly measured between the third and fourth excited states. The energy relaxation times between states connected by single-photon and multi-photon transitions were approximately 30 - 100 microseconds. Three-photon coherent oscillations were observed between the qubit ground and fourth excited states with a decoherence time of approximately 50 nanoseconds.
The superconducting quantum annealing circuit is constructed with four Nb layers and Josephson junctions with a critical current density of 1 μA/μm2. Three key points exist to perform the quantum annealing in experiments. First, the shape of the energy potential of the qubit should be accurately designed. Second, the current pulses for modulation of the shape of the energy potential must propagate to the qubit accurately. Third is the suppression of noise in the environment where the qubit is placed. Furthermore, calibration of the measurement data is necessary with consideration of the experimental environment. In this paper, I will present a mechanism for realizing quantum annealing from two perspectives: a theoretical model and an experiment. Experimental findings on quantum annealing will contribute to study of the surrounding circuit of a gate-type quantum computer.
Fluxonium superconducting qubits have demonstrated long coherence times and high single- and two-qubit gate fidelities, making them a favorable building block for superconducting quantum processors. We investigate the dominant limitations to fluxonium qubit energy relaxation time T1T_1T1​ using a set of eight planar, aluminum-on-silicon qubits. We find that a circuit-based model for capacitive dielectric loss best captures the frequency dependence of T1T_1T1​, which we analyze within both a two-level and a six-level energy relaxation model. We convert the measured T1T_1T1​ into an effective capacitive quality factor QCeffQ_\mathrm{C}^{\mathrm{eff}}QCeff​ to compare qubits on equal footing, accounting for independently estimated contributions from 1/f1/f1/f flux noise and radiative loss to the control and readout circuitry. We apply this methodology to compare qubits from two fabrication processes: a baseline process and one that applies a fluorine-based wet treatment prior to Josephson junction deposition. We resolve a small improvement of (13.8 ±\pm± 8.4)%)\%)% in the process mean QCeffQ_\mathrm{C}^{\mathrm{eff}}QCeff​, indicating that the fluorine treatment may have reduced loss from the metal-substrate interface, but did not address the primary source of loss in these fluxonium qubits.