Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Frequency stabilization of lasers by locking to an atomic isoclinic point

N. P. Wells, James C. Camparo

Published Jun 1, 2010• 1 citation
Publisher

Abstract

To overcome the temperature sensitivity of lasers locked to Doppler-broadened transitions, we propose a scheme in which the laser is locked to an isoclinic point of the atom's spectrum: a frequency at which the first derivative of the absorption spectrum does not change upon a physical change of the sample. Here, we demonstrate that an isoclinic point exists in the Rb87D1spectrum at 795 nm, and that it is located midway between the Fg=2 → Fe=1 and Fg=2 → Fe=2 transitions. Locking a VCSEL diode laser to this isoclinic point, we have been able to demonstrate a very low sensitivity of the locked laser's frequency to temperature variations of the atomic vapor.

DOI
10.1109/freq.2010.5556317

Related papers

Frequency Stabilization of Diode Laser Using Dichroic-Atomic-Vapor Laser Lock Signals and Thin Rb Vapor Cell

Sayaka Imanishi, U. Tanaka, Shinji Urabe

We report the frequency stabilization of a diode laser by applying the dichroic-atomic-vapor laser lock (DAVLL) method to a thin Rb vapor cell. A 1-mm-long Rb vapor cell is used to obtain a sub-Doppler spectrum that is required for frequency locking, which is easier than in the case of using a saturated absorption spectrometer. A 794-nm diode laser is tuned to the Rb D 1 line, and sub-Doppler signals are observed by introducing a pumping beam and a probe beam in a perpendicular direction. We obtain error signals by subtracting the signals of σ+ polarized beams from that of σ- polarized beams in the presence of a magnetic field and stabilized the 794 nm diode laser frequency without modulating laser parameters. The stability of the 794-nm diode laser is evaluated using other independently stabilized diode laser.

Japanese Journal of Applied Physics•Sep 1, 2005•14 citations

Frequency-stabilized diode laser with the Zeeman shift in an atomic vapor

Kristan L. Corwin, Zheng‐Tian Lu, Carter F. Hand +2 more

We demonstrate a robust method of stabilizing a diode laser frequency to an atomic transition. This technique employs the Zeeman shift to generate an antisymmetric signal about a Doppler-broadened atomic resonance, and therefore offers a large recapture range as well as high stability. The frequency of a 780-nm diode laser, stabilized to such a signal in Rb, drifted less than 0.5 MHz peak-peak (1 part in 10(9)) in 38 h. This tunable frequency lock can be constructed inexpensively, requires little laser power, rarely loses lock, and can be extended to other wavelengths by use of different atomic species.

Applied Optics•May 20, 1998•381 citations

Temperature-insensitive laser frequency stabilization with magnetic tuning

Lucas J. Willis, M. J. Lim

We have implemented a tunable laser frequency lock with a wide recapture range and low sensitivity to temperature fluctuation, based on electronically power-normalized Doppler-broadened absorption spectra. The method requires no frequency modulation. A distributed-feedback diode laser locked to this system exhibits submegahertz stability over many hours. It has been used to magneto-optically trap rubidium atoms for a full day.

Applied Optics•Apr 24, 2008•5 citations

Rb87 D1 isoclinic point

N. P. Wells, James C. Camparo

In the research presented here, we reconsider the problem of obtaining stable resonant features in linear absorption spectroscopy, which has application to ultraminiature atomic physics where sub-Doppler spectroscopic techniques are not always optimal. In particular, we consider the applicability of isoclinic points for precision atomic spectroscopy. These are defined as ``[a] wavelength, wave number, or frequency at which the first derivative of an absorption spectrum of a sample does not change upon a chemical reaction or physical change of the sample,'' and we demonstrate the existence of isoclinic points in the ${D}_{1}$ spectra of $I=3/2$ alkali-metal isotopes, where $I$ is the nuclear spin. We then consider the ${D}_{1}$ isoclinic point of $^{87}\mathrm{Rb}$ in detail, showing that a slight $^{85}\mathrm{Rb}$ contamination in real $^{87}\mathrm{Rb}$ samples should have no significant effect on the frequency stability of the isoclinic point and that optical pumping by a linearly polarized laser should also not affect the isoclinic point's stability (i.e., the isoclinic point is insensitive to laser intensity). Finally, we perform an experiment demonstrating that the $^{87}\mathrm{Rb}$ ${D}_{1}$ isoclinic point has a temperature shift more than an order of magnitude smaller than that of the most isolated transition in the $^{87}\mathrm{Rb}$ ${D}_{1}$ spectrum.

Physical Review A•Dec 7, 2010•14 citations

Laser frequency locking by dispersive response of atoms in transversal magnetic field

Taro Hasegawa, Mitsuyasu Deguchi

A robust laser-frequency-locking scheme to atomic transitions is proposed and demonstrated. In this scheme, dispersion of the Zeeman-shifted atoms instead of absorption in the dichroic atomic vapor laser lock (DAVLL) [Appl. Opt.37, 3295 (1998)] is measured and used as an error signal for stabilization feedback. The error signal of the proposed scheme can provide a wide locking range. Experimental demonstration with the transition between 5d 2D3/2 and 6p 2P1/2 of Ba+ is carried out for a grating feedback external-cavity laser diode at 650 nm.

Journal of the Optical Society of America B•May 13, 2009•11 citations

A home-built lock-in amplifier for laser frequency stabilization

K Sowka, M. Weel, S. Cauchi +2 more

We describe an inexpensive lock-in amplifier that can be built using discrete off-the-shelf RF components and home-built analog circuits. This lock-in has been used in a feedback loop to lock the frequency of a laser to an atomic transition. The frequency stability was tested by trapping rubidium atoms. The feedback loop involves obtaining a modulated saturated absorption signal from a vapor cell using an acousto-optic modulator to modulate the laser frequency. The absorption signal is sent to the lock-in to generate an error signal, proportional to the first derivative of the absorption, which is fed back to the laser to complete the feedback loop. We also demonstrate a simplified optical setup for viewing the saturated absorption spectrum. In this case, the signal consists of narrow saturated absorption spectra riding on top of a Doppler-broadened pedestal. We show that it is possible to greatly reduce the effect of this background and lock the laser to the atomic resonance by modifying the home-built lock-in to generate an error signal proportional to the third derivative of the absorption. The results of this work can be adapted for advanced undergraduate laboratory work.PACS Nos.: 01.50Pa, 07.50.–e, 42.62Fi, 42.60Fc

Canadian Journal of Physics•Sep 1, 2005•14 citations
To overcome the temperature sensitivity of lasers locked to Doppler-broadened transitions, we propose a scheme in which the laser is locked to an isoclinic point of the atom's spectrum: a frequency at which the first derivative of the absorption spectrum does not change upon a physical change of the sample. Here, we demonstrate that an isoclinic point exists in the Rb87D1spectrum at 795 nm, and that it is located midway between the Fg=2 → Fe=1 and Fg=2 → Fe=2 transitions. Locking a VCSEL diode laser to this isoclinic point, we have been able to demonstrate a very low sensitivity of the locked laser's frequency to temperature variations of the atomic vapor.
We report the frequency stabilization of a diode laser by applying the dichroic-atomic-vapor laser lock (DAVLL) method to a thin Rb vapor cell. A 1-mm-long Rb vapor cell is used to obtain a sub-Doppler spectrum that is required for frequency locking, which is easier than in the case of using a saturated absorption spectrometer. A 794-nm diode laser is tuned to the Rb D 1 line, and sub-Doppler signals are observed by introducing a pumping beam and a probe beam in a perpendicular direction. We obtain error signals by subtracting the signals of σ+ polarized beams from that of σ- polarized beams in the presence of a magnetic field and stabilized the 794 nm diode laser frequency without modulating laser parameters. The stability of the 794-nm diode laser is evaluated using other independently stabilized diode laser.
We demonstrate a robust method of stabilizing a diode laser frequency to an atomic transition. This technique employs the Zeeman shift to generate an antisymmetric signal about a Doppler-broadened atomic resonance, and therefore offers a large recapture range as well as high stability. The frequency of a 780-nm diode laser, stabilized to such a signal in Rb, drifted less than 0.5 MHz peak-peak (1 part in 10(9)) in 38 h. This tunable frequency lock can be constructed inexpensively, requires little laser power, rarely loses lock, and can be extended to other wavelengths by use of different atomic species.
In the research presented here, we reconsider the problem of obtaining stable resonant features in linear absorption spectroscopy, which has application to ultraminiature atomic physics where sub-Doppler spectroscopic techniques are not always optimal. In particular, we consider the applicability of isoclinic points for precision atomic spectroscopy. These are defined as ``[a] wavelength, wave number, or frequency at which the first derivative of an absorption spectrum of a sample does not change upon a chemical reaction or physical change of the sample,'' and we demonstrate the existence of isoclinic points in the D1{D}_{1}D1​ spectra of I=3/2I=3/2I=3/2 alkali-metal isotopes, where III is the nuclear spin. We then consider the D1{D}_{1}D1​ isoclinic point of 87Rb^{87}\mathrm{Rb}87Rb in detail, showing that a slight 85Rb^{85}\mathrm{Rb}85Rb contamination in real 87Rb^{87}\mathrm{Rb}87Rb samples should have no significant effect on the frequency stability of the isoclinic point and that optical pumping by a linearly polarized laser should also not affect the isoclinic point's stability (i.e., the isoclinic point is insensitive to laser intensity). Finally, we perform an experiment demonstrating that the 87Rb^{87}\mathrm{Rb}87Rb D1{D}_{1}D1​ isoclinic point has a temperature shift more than an order of magnitude smaller than that of the most isolated transition in the 87Rb^{87}\mathrm{Rb}87Rb D1{D}_{1}D1​ spectrum.
A robust laser-frequency-locking scheme to atomic transitions is proposed and demonstrated. In this scheme, dispersion of the Zeeman-shifted atoms instead of absorption in the dichroic atomic vapor laser lock (DAVLL) [Appl. Opt.37, 3295 (1998)] is measured and used as an error signal for stabilization feedback. The error signal of the proposed scheme can provide a wide locking range. Experimental demonstration with the transition between 5d 2D3/2 and 6p 2P1/2 of Ba+ is carried out for a grating feedback external-cavity laser diode at 650 nm.
We describe an inexpensive lock-in amplifier that can be built using discrete off-the-shelf RF components and home-built analog circuits. This lock-in has been used in a feedback loop to lock the frequency of a laser to an atomic transition. The frequency stability was tested by trapping rubidium atoms. The feedback loop involves obtaining a modulated saturated absorption signal from a vapor cell using an acousto-optic modulator to modulate the laser frequency. The absorption signal is sent to the lock-in to generate an error signal, proportional to the first derivative of the absorption, which is fed back to the laser to complete the feedback loop. We also demonstrate a simplified optical setup for viewing the saturated absorption spectrum. In this case, the signal consists of narrow saturated absorption spectra riding on top of a Doppler-broadened pedestal. We show that it is possible to greatly reduce the effect of this background and lock the laser to the atomic resonance by modifying the home-built lock-in to generate an error signal proportional to the third derivative of the absorption. The results of this work can be adapted for advanced undergraduate laboratory work.PACS Nos.: 01.50Pa, 07.50.–e, 42.62Fi, 42.60Fc