Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement Science and Technology

Automatic minimisation of micromotion in a 88 Sr + optical clock

G. P. Barwood, Guozheng Huang, Hugh A. Klein, Patrick Robert Gill

Published Jun 12, 2015• 1 citation
Publisher

Abstract

Abstract Optical clocks based on narrow linewidth transitions in single cold ions confined in RF traps are being developed at a number of laboratories worldwide. For these ion clock systems, excess micromotion can cause both Stark and Doppler frequency shifts and also a degradation of frequency stability as a result of a reduced excitation rate to the clock transition. At NPL, we detect micromotion in our 88 Sr + optical clocks by observing the correlation between photon arrival times and the zero crossing of the RF trap drive signal. Recently, two nominally identical 88 Sr + optical clocks have been operated over several days and their frequencies compared against one another. During this time the dc voltages on the endcap and compensation voltage electrodes required to minimise the micromotion can change significantly, particularly following the loading of an ion. This paper describes an automatic method to monitor and minimise micromotion applicable to single ion clocks and which we demonstrate using our two NPL 88 Sr + ion clocks.

DOI
10.1088/0957-0233/26/7/075203

Related papers

171Yb+ ion optical clock at NPL: advances in automation and assessment of the trap-induced ac Zeeman shift in an endcap trap geometry

E. A. Curtis, Alexandra Tofful, Adam O. Parsons +2 more

Abstract Ensuring robust operation of optical clock systems requires increasingly complex automation of experimental protocols. This includes real-time monitoring of system output for data validation and for high accuracy assessment of systematic frequency shifts. We report here on recent advances in the control system of the 171 Yb+ ion optical clock at NPL (National Physical Laboratory, UK) and describe how this has led to improvements in systematic shift metrology and reduced the overall uncertainty budget for the optical clock. Additionally we present an assessment of the rf trap drive-induced ac Zeeman effect for our experimental system. These system advances enable us to provide improved contributions to the international efforts in the redefinition of the SI second and other applications such as tests of fundamental physics.

Journal of Physics Conference Series•Nov 1, 2024•1 citation

Micromotion minimisation by synchronous detection of parametrically excited motion

D. P. Nadlinger, P. Drmota, D. Main +6 more

Precise control of charged particles in radio-frequency (Paul) traps requires minimising excess micromotion induced by stray electric fields. We present a method to detect and compensate such fields through amplitude modulation of the radio-frequency trapping field. Modulation at frequencies close to the motional modes of the trapped particle excites coherent motion whose amplitude linearly depends on the stray field. In trapped-ion experiments, this motion can be detected by recording the arrival times of photons scattered during laser cooling. Only a single laser beam is required to resolve fields in multiple directions. In a demonstration using a $^{88}\mathrm{Sr}^{+}$ ion in a surface electrode trap, we achieve a sensitivity of $0.1\, \mathrm{V}\, \mathrm{m}^{-1}\, /\, \sqrt{\mathrm{Hz}}$ and a minimal uncertainty of $0.015\, \mathrm{V}\, \mathrm{m}^{-1}$.

arXiv:2107.00056•Jun 30, 2021•13 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG +6 more

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Minimization of ion micromotion in a Paul trap

Dana J. Berkeland, J.D. Miller, Jonas Bergquist +2 more

Micromotion of ions in Paul traps has several adverse effects, including alterations of atomic transition line shapes, significant second-order Doppler shifts in high-accuracy studies, and limited confinement time in the absence of cooling. The ac electric field that causes the micromotion may also induce significant Stark shifts in atomic transitions. We describe three methods of detecting micromotion. The first relies on the change of the average ion position as the trap potentials are changed. The second monitors the amplitude of the sidebands of a narrow atomic transition, caused by the first-order Doppler shift due to the micromotion. The last technique detects the Doppler shift induced modulation of the fluorescence rate of a broad atomic transition. We discuss the detection sensitivity of each method to Doppler and Stark shifts, and show experimental results using the last technique.

Journal of Applied Physics•May 15, 1998•733 citations
Abstract Optical clocks based on narrow linewidth transitions in single cold ions confined in RF traps are being developed at a number of laboratories worldwide. For these ion clock systems, excess micromotion can cause both Stark and Doppler frequency shifts and also a degradation of frequency stability as a result of a reduced excitation rate to the clock transition. At NPL, we detect micromotion in our 88 Sr + optical clocks by observing the correlation between photon arrival times and the zero crossing of the RF trap drive signal. Recently, two nominally identical 88 Sr + optical clocks have been operated over several days and their frequencies compared against one another. During this time the dc voltages on the endcap and compensation voltage electrodes required to minimise the micromotion can change significantly, particularly following the loading of an ion. This paper describes an automatic method to monitor and minimise micromotion applicable to single ion clocks and which we demonstrate using our two NPL 88 Sr + ion clocks.
Abstract Ensuring robust operation of optical clock systems requires increasingly complex automation of experimental protocols. This includes real-time monitoring of system output for data validation and for high accuracy assessment of systematic frequency shifts. We report here on recent advances in the control system of the 171 Yb+ ion optical clock at NPL (National Physical Laboratory, UK) and describe how this has led to improvements in systematic shift metrology and reduced the overall uncertainty budget for the optical clock. Additionally we present an assessment of the rf trap drive-induced ac Zeeman effect for our experimental system. These system advances enable us to provide improved contributions to the international efforts in the redefinition of the SI second and other applications such as tests of fundamental physics.
Precise control of charged particles in radio-frequency (Paul) traps requires minimising excess micromotion induced by stray electric fields. We present a method to detect and compensate such fields through amplitude modulation of the radio-frequency trapping field. Modulation at frequencies close to the motional modes of the trapped particle excites coherent motion whose amplitude linearly depends on the stray field. In trapped-ion experiments, this motion can be detected by recording the arrival times of photons scattered during laser cooling. Only a single laser beam is required to resolve fields in multiple directions. In a demonstration using a 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ ion in a surface electrode trap, we achieve a sensitivity of 0.1 V m−1 / Hz0.1\, \mathrm{V}\, \mathrm{m}^{-1}\, /\, \sqrt{\mathrm{Hz}}0.1Vm−1/Hz​ and a minimal uncertainty of 0.015 V m−10.015\, \mathrm{V}\, \mathrm{m}^{-1}0.015Vm−1.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
Micromotion of ions in Paul traps has several adverse effects, including alterations of atomic transition line shapes, significant second-order Doppler shifts in high-accuracy studies, and limited confinement time in the absence of cooling. The ac electric field that causes the micromotion may also induce significant Stark shifts in atomic transitions. We describe three methods of detecting micromotion. The first relies on the change of the average ion position as the trap potentials are changed. The second monitors the amplitude of the sidebands of a narrow atomic transition, caused by the first-order Doppler shift due to the micromotion. The last technique detects the Doppler shift induced modulation of the fluorescence rate of a broad atomic transition. We discuss the detection sensitivity of each method to Doppler and Stark shifts, and show experimental results using the last technique.