Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Optical-clock local-oscillator stabilization scheme

V. Letchumanan, Patrick Robert Gill, Alastair G. Sinclair, Erling Riis

Published Apr 1, 2006• 8 citations
Publisher

Abstract

Stabilization of a laser to an optical-clock transition has been demonstrated using Ramsey's phase-modulation technique. The technique was implemented using a 674 nm laser and a component of the 5 s 2S1/2 → 4d 2D5/2 optical clock transition in a single 88Sr+ ion. The lock performance observed was consistent with the short-term stability of the local oscillator. Compared with existing frequency-modulation stabilization schemes, this technique offers advantages for use in single-ion optical clocks through its possible increased resolution and the ability to conveniently compensate known systematic shifts.

DOI
10.1364/josab.23.000714

Related papers

Novel local oscillator stabilization scheme for optical clocks

Alastair G. Sinclair, V. Letchumanan, Patrick Robert Gill +1 more

Controlled modulation of laser phase in an optical Ramsey experiment yields an antisymmetric lineshape. This discriminant is used to stabilize a local oscillator to the optical clock transition in a single 88Sr+ ion.

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

Subkilohertz comparison of the single-ion optical-clock 2S1/2−2D5/2 transition in two 88Sr+ traps

G. P. Barwood, Guozheng Huang, Hugh A. Klein +2 more

A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single ${}^{88}{\mathrm{Sr}}^{+}$ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in ${10}^{11}$ per hour. The difference between center frequencies of the single ${}^{88}{\mathrm{Sr}}^{+}$-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in ${10}^{13}.$

Physical Review A•May 1, 1999•27 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•301 citations

Optical Atomic Clock and Laser Applications to Length and Time Metrology

Ye Jiang, Yuefeng Huang, K. Gao

In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.

CRC Press eBooks•Apr 29, 2021•0 citations

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG +6 more

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Frequency Locking and Power Enhancement by Coherent Addition of a Clock Laser for a Portable Multi-40Ca+ Optical Clock

Akira Nagano, U. Tanaka, Kazuhiro Hayasaka

Summary—We construct a frequency locking system for a portable multi-ion optical clock and develop a clock laser whose power is enhanced by the coherent addition method. We reduce the feedback cycle time down to 50 ms, which realizes short-term stabilization with a commercial confocal cavity. To excite the clock transition at 729 nm of multiple ions, we perform coherent addition of 1458-nm optical amplifier outputs and obtain 100 mW at 729 nm by second-harmonic generation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations
Stabilization of a laser to an optical-clock transition has been demonstrated using Ramsey's phase-modulation technique. The technique was implemented using a 674 nm laser and a component of the 5 s 2S1/2 → 4d 2D5/2 optical clock transition in a single 88Sr+ ion. The lock performance observed was consistent with the short-term stability of the local oscillator. Compared with existing frequency-modulation stabilization schemes, this technique offers advantages for use in single-ion optical clocks through its possible increased resolution and the ability to conveniently compensate known systematic shifts.
A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in 1011{10}^{11}1011 per hour. The difference between center frequencies of the single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in 1013.{10}^{13}.1013.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.