Abstract

For nearly fifty years, atomic resonances have been employed to stabilize electromagnetic field frequency. Here, a dynamical Rabi resonance, associated with an alkali atom's ground state hyperfine transition, is used to stabilize electromagnetic field strength: A 7% sinusoidal variation was superimposed on a microwave field's strength, and through atomic stabilization this variation was reduced to 0.1%. Although the method is demonstrated with microwave fields, the technique could also be employed to stabilize optical fields via Rabi resonances associated with electronic transitions in atoms or molecules.

DOI
10.1103/physrevlett.80.222

Related papers

Atomic stabilization of electromagnetic field-strength and the gas-cell atomic clock

James C. Camparo

For nearly fifty years atomic resonances have been employed to stabilize electromagnetic field frequency. Here, an atom's dynamical "Rabi-resonance" is used to stabilize electromagnetic field-strength. Though the method is demonstrated with microwave fields, the technique could also be employed to stabilize optical fields via Rabi-resonances associated with electronic transitions in atoms or molecules.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•3 citations

Atomic stabilization of field intensity using Rabi resonances

John G. Coffer, James C. Camparo

Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, it is possible to stabilize the intensity or brightness of a field to an atomic Rabi resonance. For ease of reference, such a stabilized field is termed an ``atomic candle.'' Here, we describe a microwave atomic candle based on the $(F=2,$ ${m}_{F}=0)$--$(F=1,$ ${m}_{F}=0)$ ground-state hyperfine transition of ${}^{87}\mathrm{Rb}$ (6834.7 MHz) as observed in an optically pumped vapor. We discuss the atomic candle's operation and the intensity stability of the field it produces (relative to the Rabi-resonance peak). We then discuss our use of the candle to investigate Rabi-resonance shifts. Specifically, we find that the Rabi resonance depends on the ac Stark shift of the hyperfine transition, the microwave field-atom detuning, and the alkali-metal vapor temperature.

Physical Review A•Jun 15, 2000•33 citations

The "atomic candle:" progress towards a smart rubidium atomic clock [and application to microwave dielectric measurements]

James C. Camparo

Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. We term such a device an "atomic candle." We describe the operation of a microwave atomic candle based on the 0-0 ground state hyperfine transition in /sup 87/Rb, and our experiments examining its stability and sensitivity to various experimental parameters. Specifically, we have measured the microwave power stability of our candle, relative to the peak of the Rabi-resonance, and obtained /spl sigma//sub /spl Delta/P/P/(/spl tau/)=9/spl times/10/sup -7/+10/sup -7//spl radic//spl tau/. Additionally, we examined the Rabi-resonance shift as a function of various experimental parameters including microwave detuning from the 0-0 resonance and resonance-cell temperature. The paper concludes with a discussion of a novel application of the atomic candle: the precision measurement of a material's complex dielectric constant.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 8, 2002•3 citations

THE "ATOMIC CANDLE": STABILIZING FIELD AMPLITUDE USING RABI-RESONANCES

James C. Camparo

Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. For ease of reference, we term such a device an "atomic candle." Originally, the atomic candle was developed to stabilize microwave power in the gas-cell atomic clock, thereby eliminating the clock's instability due to microwave power variations. However, atomic candle applications may extend well beyond the area of precise timekeeping, since the device basically provides a means for detecting subtle amplitude changes in strong electromagnetic fields. Here, we describe the general operation of the atomic candle and discuss some of its potential applications.

Symposium on Frequency Standards and Metrology•May 1, 2002•0 citations

Microwave magnetic field strength imaging based on Rabi resonance with alkali-atom vapor cell

Lang Chen, Minghao Yao, Yang Shi +6 more

The present Rabi resonance microwave sensing technique cannot fully describe the microwave magnetic field strength distribution due to the signal detection method. Here, we propose an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell. The experimental results well describe the distribution of the microwave field quantitatively and agree with the absorption imaging results. This technique can also be used as a method to analyze and measure the relaxation rate in an atomic vapor cell and offers a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.

Applied Physics Letters•Jun 6, 2022•7 citations

On Rabi oscillations in ground hyperfine states of 87Rb atom driven by a microwave field

S. Sarkar, Vivek Singh, K. A. P. Singh +3 more

We have observed the Rabi oscillations of the population of $$^{87}Rb$$ atoms in the hyperfine ground state, when a cold atom cloud prepared in the hyperfine ground state ( $$F = 1$$ ) was exposed to a microwave (MW) radiation field resonant to the $$|F = 1, m_{F} = 0>$$ $$\rightarrow$$ $$|F = 2, m_{F} = 0>$$ transition. After exposure to MW field, the atom cloud was imaged using the absorption probe method. The absorption images have revealed that population excited to the hyperfine state ( $$F = 2$$ ) varied with the position in the atom cloud, showing the position dependent atom-field coupling strength. At a given position in the atom cloud, the excited population shows Rabi oscillations between two hyperfine states. Thus, we have demonstrated that by measuring the position dependent Rabi frequency, the spatial variation of magnetic field can be measured using a cold atom cloud.

Applied Physics B•Jul 8, 2025•0 citations
For nearly fifty years, atomic resonances have been employed to stabilize electromagnetic field frequency. Here, a dynamical Rabi resonance, associated with an alkali atom's ground state hyperfine transition, is used to stabilize electromagnetic field strength: A 7% sinusoidal variation was superimposed on a microwave field's strength, and through atomic stabilization this variation was reduced to 0.1%. Although the method is demonstrated with microwave fields, the technique could also be employed to stabilize optical fields via Rabi resonances associated with electronic transitions in atoms or molecules.
Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, it is possible to stabilize the intensity or brightness of a field to an atomic Rabi resonance. For ease of reference, such a stabilized field is termed an ``atomic candle.'' Here, we describe a microwave atomic candle based on the (F=2,(F=2,(F=2, mF=0){m}_{F}=0)mF​=0)--(F=1,(F=1,(F=1, mF=0){m}_{F}=0)mF​=0) ground-state hyperfine transition of 87Rb{}^{87}\mathrm{Rb}87Rb (6834.7 MHz) as observed in an optically pumped vapor. We discuss the atomic candle's operation and the intensity stability of the field it produces (relative to the Rabi-resonance peak). We then discuss our use of the candle to investigate Rabi-resonance shifts. Specifically, we find that the Rabi resonance depends on the ac Stark shift of the hyperfine transition, the microwave field-atom detuning, and the alkali-metal vapor temperature.
Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. We term such a device an "atomic candle." We describe the operation of a microwave atomic candle based on the 0-0 ground state hyperfine transition in /sup 87/Rb, and our experiments examining its stability and sensitivity to various experimental parameters. Specifically, we have measured the microwave power stability of our candle, relative to the peak of the Rabi-resonance, and obtained /spl sigma//sub /spl Delta/P/P/(/spl tau/)=9/spl times/10/sup -7/+10/sup -7//spl radic//spl tau/. Additionally, we examined the Rabi-resonance shift as a function of various experimental parameters including microwave detuning from the 0-0 resonance and resonance-cell temperature. The paper concludes with a discussion of a novel application of the atomic candle: the precision measurement of a material's complex dielectric constant.
Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. For ease of reference, we term such a device an "atomic candle." Originally, the atomic candle was developed to stabilize microwave power in the gas-cell atomic clock, thereby eliminating the clock's instability due to microwave power variations. However, atomic candle applications may extend well beyond the area of precise timekeeping, since the device basically provides a means for detecting subtle amplitude changes in strong electromagnetic fields. Here, we describe the general operation of the atomic candle and discuss some of its potential applications.
The present Rabi resonance microwave sensing technique cannot fully describe the microwave magnetic field strength distribution due to the signal detection method. Here, we propose an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell. The experimental results well describe the distribution of the microwave field quantitatively and agree with the absorption imaging results. This technique can also be used as a method to analyze and measure the relaxation rate in an atomic vapor cell and offers a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.
We have observed the Rabi oscillations of the population of 87Rb^{87}Rb87Rb atoms in the hyperfine ground state, when a cold atom cloud prepared in the hyperfine ground state ( F=1F = 1F=1 ) was exposed to a microwave (MW) radiation field resonant to the ∣F=1,mF=0>|F = 1, m_{F} = 0>∣F=1,mF​=0> →\rightarrow→ ∣F=2,mF=0>|F = 2, m_{F} = 0>∣F=2,mF​=0> transition. After exposure to MW field, the atom cloud was imaged using the absorption probe method. The absorption images have revealed that population excited to the hyperfine state ( F=2F = 2F=2 ) varied with the position in the atom cloud, showing the position dependent atom-field coupling strength. At a given position in the atom cloud, the excited population shows Rabi oscillations between two hyperfine states. Thus, we have demonstrated that by measuring the position dependent Rabi frequency, the spatial variation of magnetic field can be measured using a cold atom cloud.