Physical Review A

Microwave-cavity modes directly observed in a Penning trap

Robert S. Van Dyck, Fred L. Moore, Dean L. Farnham, Paul B. Schwinberg, HANS G. DEHMELT

Published Oct 1, 1987• 14 citations
Publisher

Abstract

The microwave-cavity mode pattern has been directly observed in an old-style compensated Penning trap by a simple bolometric technique which monitors changes in the temperature of the axial center-of-mass motion for a cloud of electrons. The method allows one to easily determine the position of individual modes to a precision better than 0.01%. Presently, over 60 modes have been observed for fields between 17 and 60 kG and an upper limit estimate of 2300 has been made for the cavity Q.

DOI
10.1103/physreva.36.3455

Related papers

Electrostatic modes as a diagnostic in Penning trap experiments

Carl S. Weimer, J. J. Bollinger, David J. Wineland +1 more

A subset of electrostatic modes of a cold cloud of electrons trapped in a Penning trap has been observed and identified using a recent theoretical model. The detection of these modes is accomplished using electronic techniques which could apply to any ion species. The modes are observed in the low density, low rotation limit of the cloud where the electrons approach a two-dimensional charged disk. We observe both axially symmetric and asymmetric drumhead modes. By measuring the frequency of these modes the shape, rotation frequency, and density of the cloud is found in a real-time non-destructive manner. In addition, it is found that radio-frequency sideband cooling compresses the cloud increasing its density. The ability to measure and control the density of a trapped ion cloud might be useful for experiments on low-temperature ion/neutral collisions or recombination rates.

Bulletin of the American Physical Society•May 1, 1993•0 citations

Eliminating cavity shifts from electron magnetic moment (g-2) measurements

G. Gabrielse

A cylindrical Penning trap is of such high quality that a single electron is observed with good signal-to-noise. The trap is also a good approximation to an ideal cylindrical microwave cavity. This is documented in situ at 4 K with a new probe utilizing trapped electrons. An extraordinary control of the cavity-electron interaction results and opens the way to a new generation of electron magnetic moment measurements, not limited by either cavity frequency shifts or damping widths, and to sideband cooling of an electron motion to very low (mK) temperatures.

Bulletin of the American Physical Society•May 1, 1993•0 citations

Demonstration of a Spherical Penning Trap for Single Electrons

Zirui Fang, Xing Fan

A spherical Penning trap has well-separated, clean microwave resonances, making it attractive for precision measurements of the electron magnetic moment and for dark-photon and axion searches with trapped electrons. We demonstrate single-electron trapping in a spherical Penning trap and characterize its microwave resonance structure. The design, single-electron detection, microwave mode characterization, and advantages of this geometry are presented.

physics.atom-phCross-listedarXiv:2606.03639•Jun 3, 2026

Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap

S. Ulmer, K. Blaum, Holger Kracke +4 more

A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.

Physical Review Letters•Sep 1, 2011•23 citations

Chapter 11: Novel Penning Traps

J. Verdú

Penning traps are used in a wide variety of applications, such as mass spectrometry, high precision measurements of atomic and nuclear properties, antihydrogen production and others. The maturity achieved by Penning trap technology has recently led to several theoretical proposals about the construction of a quantum processor using trapped electrons. Novel scalable surface traps have been conceived of and actually built. However, the observation of a single trapped electron and the accurate measurement of its motional frequencies is still an open experimental challenge. At the University of Sussex a new approach has been introduced: the coplanar-waveguide Penning trap. We describe this trap in detail and discuss how the compensation of electric anharmonicities might allow for the observation of a single electron.

IMPERIAL COLLEGE PRESS eBooks•Feb 11, 2014•0 citations

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations
The microwave-cavity mode pattern has been directly observed in an old-style compensated Penning trap by a simple bolometric technique which monitors changes in the temperature of the axial center-of-mass motion for a cloud of electrons. The method allows one to easily determine the position of individual modes to a precision better than 0.01%. Presently, over 60 modes have been observed for fields between 17 and 60 kG and an upper limit estimate of 2300 has been made for the cavity Q.
A subset of electrostatic modes of a cold cloud of electrons trapped in a Penning trap has been observed and identified using a recent theoretical model. The detection of these modes is accomplished using electronic techniques which could apply to any ion species. The modes are observed in the low density, low rotation limit of the cloud where the electrons approach a two-dimensional charged disk. We observe both axially symmetric and asymmetric drumhead modes. By measuring the frequency of these modes the shape, rotation frequency, and density of the cloud is found in a real-time non-destructive manner. In addition, it is found that radio-frequency sideband cooling compresses the cloud increasing its density. The ability to measure and control the density of a trapped ion cloud might be useful for experiments on low-temperature ion/neutral collisions or recombination rates.
A cylindrical Penning trap is of such high quality that a single electron is observed with good signal-to-noise. The trap is also a good approximation to an ideal cylindrical microwave cavity. This is documented in situ at 4 K with a new probe utilizing trapped electrons. An extraordinary control of the cavity-electron interaction results and opens the way to a new generation of electron magnetic moment measurements, not limited by either cavity frequency shifts or damping widths, and to sideband cooling of an electron motion to very low (mK) temperatures.
Penning traps are used in a wide variety of applications, such as mass spectrometry, high precision measurements of atomic and nuclear properties, antihydrogen production and others. The maturity achieved by Penning trap technology has recently led to several theoretical proposals about the construction of a quantum processor using trapped electrons. Novel scalable surface traps have been conceived of and actually built. However, the observation of a single trapped electron and the accurate measurement of its motional frequencies is still an open experimental challenge. At the University of Sussex a new approach has been introduced: the coplanar-waveguide Penning trap. We describe this trap in detail and discuss how the compensation of electric anharmonicities might allow for the observation of a single electron.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.