Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Europhysics Letters (EPL)

Microwave-Optical Double Resonance on a Single Laser-Cooled 171 Yb + Ion

V. Enders, Ph. W. Courteille, R. Huesmann, L. S Ma, Werner Neuhauser, R. Blatt, P. E. Toschek

Published Nov 10, 1993• 18 citations
Publisher

Abstract

A single ion whose energy levels are hyperfine split, 171 Yb + , was electrodynamically trapped and laser cooled. The residual energy of both its driven motion and its secular motion was 11 μeV. Radiofrequency-optical double-resonance excitation yields spectra whose 40 Hz wide lines are determined so far by the duration of the ion's interaction with the 12.6 GHz radiation. These results prove that a microwave clock is feasible with its fractional systematic uncertainty not exceeding 10 −16 .

DOI
10.1209/0295-5075/24/5/002

Related papers

Microwave-optical double resonance on a single laser-cooled 171 Yb + ion

V. Enclers, Ph. W. Courteille, R. Huesmann +4 more

The ground-state hyperfine transitions of trapped clouds of 9Be+, 201Hg+, and 171Yb ions have been made control microwave oscillators.1-5 The frequency stability of these atomic clocks exceeds that of a primary Cs frequency standard in the short-term regime and that of a hydrogen maser for long times. Systematic perturbations derive from the members of the cloud being placed in an inhomogeneous field and showing residual motion. A single cold ion kept in the field node of an electrodynamic trap lacks these perturbations. The precise control of a standard frequency requires a narrow and weak transition whose resonance can be hardly detected by observation of the fluorescence on this line.

•May 8, 1994•1 citation

A Microwave Clock Based on Laser-Cooled 171 Yb + Ions

N. C. Xin, Jianwei Zhang, S. N. Miao +5 more

A microwave frequency standard based on laser-cooled171Yb+ions at Tsinghua University has been investigated. More than 105171Yb+ions were stably trapped for over 40 hours. The ground-state hyperfine splitting frequency of171Yb+was determined to be 12642812118.4672(8) Hz with a fractional frequency uncertainty of 6.33×10−14. Our work is in a continuous line with that of other scholars.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

Ultrahigh-Resolution Microwave Spectroscopy on Trapped Yb+171 Ions

R. Blatt, H. Schnatz, Günther Werth

A laser optical-pumping, double-resonance experiment was performed on electrodynamically confined $^{171}\mathrm{Yb}^{+}$ ions. The ground-state hyperfine splitting has been determined to be $\ensuremath{\Delta}{W}_{\mathrm{h}\mathrm{f}\mathrm{s}}=12642812124.2\ifmmode\pm\else\textpm\fi{}1.4$ Hz. The ultimate linewidth obtained in this experiment was 60 mHz, corresponding to a line $Q$ of 0.2\ifmmode\times\else\texttimes\fi{}${10}^{12}$. It was limited by the stability of the available frequency reference.

Physical Review Letters•Jun 7, 1982•73 citations

Laser-cooled 171 Yb + microwave clock with a systematic uncertainty of 7.8×10 −15

Yong Chen, Y. Zheng, S. N. Miao +4 more

We present a transportable laser-cooled ion microwave clock based on the ground-state hyperfine splitting of 171 Yb + . The system achieves a systematic uncertainty of 7.8×10 −15 and a short-term frequency stability of 9.5×10 −13 / τ . Enhancements to the magnetic-field system suppress the decoherence process in the multi-body ion ensemble and reduce the second-order Zeeman frequency shift by a factor of two. The absolute microwave frequency is measured to be 12 642 812 118.468 6(3) Hz, consistent with the previous measurements and demonstrating twice the precision of the current state-of-the-art.

Optics Letters•Aug 28, 2025•2 citations

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.

Symposium on Frequency Standards and Metrology•May 1, 2002•11 citations

Progress at CSIRO Australia towards a microwave frequency standard based on trapped, laser-cooled /sup 171/Yb/sup +/ ions

Peter Fisk, M.A. Lawn, C. Coles

The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•1 citation
A single ion whose energy levels are hyperfine split, 171 Yb + , was electrodynamically trapped and laser cooled. The residual energy of both its driven motion and its secular motion was 11 μeV. Radiofrequency-optical double-resonance excitation yields spectra whose 40 Hz wide lines are determined so far by the duration of the ion's interaction with the 12.6 GHz radiation. These results prove that a microwave clock is feasible with its fractional systematic uncertainty not exceeding 10 −16 .
The ground-state hyperfine transitions of trapped clouds of 9Be+, 201Hg+, and 171Yb ions have been made control microwave oscillators.1-5 The frequency stability of these atomic clocks exceeds that of a primary Cs frequency standard in the short-term regime and that of a hydrogen maser for long times. Systematic perturbations derive from the members of the cloud being placed in an inhomogeneous field and showing residual motion. A single cold ion kept in the field node of an electrodynamic trap lacks these perturbations. The precise control of a standard frequency requires a narrow and weak transition whose resonance can be hardly detected by observation of the fluorescence on this line.
A laser optical-pumping, double-resonance experiment was performed on electrodynamically confined 171Yb+^{171}\mathrm{Yb}^{+}171Yb+ ions. The ground-state hyperfine splitting has been determined to be $\ensuremath{\Delta}{W}_{\mathrm{h}\mathrm{f}\mathrm{s}}=12642812124.2\ifmmode\pm\else\textpm\fi{}1.4$ Hz. The ultimate linewidth obtained in this experiment was 60 mHz, corresponding to a line QQQ of 0.2\ifmmode\times\else\texttimes\fi{}1012{10}^{12}1012. It was limited by the stability of the available frequency reference.
We present a transportable laser-cooled ion microwave clock based on the ground-state hyperfine splitting of 171 Yb + . The system achieves a systematic uncertainty of 7.8×10 −15 and a short-term frequency stability of 9.5×10 −13 / τ . Enhancements to the magnetic-field system suppress the decoherence process in the multi-body ion ensemble and reduce the second-order Zeeman frequency shift by a factor of two. The absolute microwave frequency is measured to be 12 642 812 118.468 6(3) Hz, consistent with the previous measurements and demonstrating twice the precision of the current state-of-the-art.
We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.
The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>