Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Observation of twin-beam-type quantum correlation in optical fiber

Jay E. Sharping, Marco Fiorentino B, Prem Kumar

Published Mar 15, 2001• 102 citations
Publisher

Abstract

We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.

DOI
10.1364/ol.26.000367

Related papers

Pulsed twin beams of light

Orhan Aytür, Prem Kumar

Pulsed twin beams of light have been generated using an optical-parametric amplifier that is pumped by the second harmonic of a mode-locked and Q-switched neodymium:yttrium aluminum garnet laser. The intensity noise levels on the direct-detected signal and idler beams are found to be correlated by more than 15 dB, and the subtracted noise falls below the quantum limit by more than 6 dB (75%). To our knowledge, this is the first observation of pulsed twin beams of light, and yields the highest quantum-noise reduction observed in any experiment to date. Our measurements are in excellent agreement with the quantum theory of a nondegenerate optical-parametric amplifier.

Physical Review Letters•Sep 24, 1990•182 citations

An all-fiber source of pulsed twin beams for quantum communication

Xueshi Guo, Xiaoying Li, Nannan Liu +2 more

Motivated by the pursuit of a simple system to produce a continuous variable non-classical light source for long-distance quantum communication, we construct an all-fiber source of pulsed twin beams in the 1550 nm band by using a high gain fiber optical parametric amplifier. The intensity-difference noise of the twin beams is below the shot noise limit by 3.1 dB (10.4 dB after correction for losses). A detailed study reveals a number of limiting factors for noise reduction. Therefore, further noise reduction will be feasible once care is taken for these limiting factors.

arXiv:1208.4971•Applied Physics Letters•Dec 24, 2012•32 citations

Multimode theory of pulsed-twin-beam generation using a high-gain fiber-optical parametric amplifier

Xueshi Guo, Xiaoying Li, Nannan Liu +1 more

We theoretically investigate the quantum-noise properties of a pulse-pumped high-gain-fiber optical parametric amplifiers (FOPAs) by using the Bogoliubov transformation in multiple frequency modes to describe the evolution of the nondegenerate signal and idler twin beams. The results show that the noise figure of the FOPA is generally greater than the 3 dB quantum limit unless the joint spectral function is factorable and the spectrum of the input signal well matches the gain spectrum in the signal band. However, the intensity-difference noise of the twin beams, which weakly depends on the joint spectral function, can be significantly less than the shot-noise limit when the temporal modes of the pump and the input signal are properly matched. Moreover, to closely resemble real experimental conditions, the quantum noise of twin beams generated from a broadband FOPA is numerically studied by taking the various kinds of experimental imperfections into account. Our study is not only useful for developing a compact fiber source of twin beams, but also helpful for understanding the quantum-noise limit of a pulse-pumped FOPA in the fiber communication system.

arXiv:1304.5318•Physical Review A•Aug 23, 2013•18 citations

Temporally Incoherent Twin Beams of Light

Orhan Aytür, Prem Kumar

Temporally incoherent twin beams of light are generated by means of an optical parametric amplifier that is pumped by the second harmonic of a Q-switched multi-longitudinal-mode Nd:YAG laser. For a parametric gain of 1·12, the intensity noise levels on the direct-detected signal and idler twin beams are found to be correlated by 1·4 dB, whereas the subtracted noise falls below the quantum limit by 0·7 ± 0·1 dB (15%). Although no direct coherence experiment is performed on the twin beams themselves, their temporal incoherence is manifested by the stringent path-length matching requirement between the pump and input signal beams.

Journal of Modern Optics•May 1, 1991•1 citation

Quantum-noise reduction with a Q-switched laser

Orhan Aytür, Prem Kumar

Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

All-fiber photon-pair source for practical quantum communications

Prem Kumar, Marco Fiorentino B, Paul L. Voss +1 more

Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.

•Jan 1, 2002•5 citations
We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.
Pulsed twin beams of light have been generated using an optical-parametric amplifier that is pumped by the second harmonic of a mode-locked and Q-switched neodymium:yttrium aluminum garnet laser. The intensity noise levels on the direct-detected signal and idler beams are found to be correlated by more than 15 dB, and the subtracted noise falls below the quantum limit by more than 6 dB (75%). To our knowledge, this is the first observation of pulsed twin beams of light, and yields the highest quantum-noise reduction observed in any experiment to date. Our measurements are in excellent agreement with the quantum theory of a nondegenerate optical-parametric amplifier.
Motivated by the pursuit of a simple system to produce a continuous variable non-classical light source for long-distance quantum communication, we construct an all-fiber source of pulsed twin beams in the 1550 nm band by using a high gain fiber optical parametric amplifier. The intensity-difference noise of the twin beams is below the shot noise limit by 3.1 dB (10.4 dB after correction for losses). A detailed study reveals a number of limiting factors for noise reduction. Therefore, further noise reduction will be feasible once care is taken for these limiting factors.
We theoretically investigate the quantum-noise properties of a pulse-pumped high-gain-fiber optical parametric amplifiers (FOPAs) by using the Bogoliubov transformation in multiple frequency modes to describe the evolution of the nondegenerate signal and idler twin beams. The results show that the noise figure of the FOPA is generally greater than the 3 dB quantum limit unless the joint spectral function is factorable and the spectrum of the input signal well matches the gain spectrum in the signal band. However, the intensity-difference noise of the twin beams, which weakly depends on the joint spectral function, can be significantly less than the shot-noise limit when the temporal modes of the pump and the input signal are properly matched. Moreover, to closely resemble real experimental conditions, the quantum noise of twin beams generated from a broadband FOPA is numerically studied by taking the various kinds of experimental imperfections into account. Our study is not only useful for developing a compact fiber source of twin beams, but also helpful for understanding the quantum-noise limit of a pulse-pumped FOPA in the fiber communication system.
Temporally incoherent twin beams of light are generated by means of an optical parametric amplifier that is pumped by the second harmonic of a Q-switched multi-longitudinal-mode Nd:YAG laser. For a parametric gain of 1·12, the intensity noise levels on the direct-detected signal and idler twin beams are found to be correlated by 1·4 dB, whereas the subtracted noise falls below the quantum limit by 0·7 ± 0·1 dB (15%). Although no direct coherence experiment is performed on the twin beams themselves, their temporal incoherence is manifested by the stringent path-length matching requirement between the pump and input signal beams.
Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.
Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.