An absolute magnetometer based on dc Superconducting QUantum Interference Devices

P. Carelli, Maria Gabriella Castellano, K Flacco, Roberto Leoni, G. Torrioli

Published Sep 1, 1997• 28 citations
Publisher

Abstract

We propose a novel device, based on a series of dc SQUIDs (direct current Superconducting QUantum Interference Devices), each one with different sensitive area, that can be used to perform absolute measurements of magnetic field. With this array, we overcome the limit of a single dc SQUID of being sensitive only to variations of the linked magnetic flux. The overall voltage-flux characteristic of our device, in fact, has a non-periodic shape that allows a clear identification of the point with zero magnetic field. We present a discussion of the working principle and of the main characteristics, which have been partially tested on a prototype.

DOI
10.1209/epl/i1997-00396-3

Related papers

Flux qubit as a sensor of magnetic flux

Evgeni V. Il’ichev, Ya. S. Greenberg

A magnetometer based on the quantum properties of a superconducting flux qubit is proposed. The main advantage of this device is that its sensitivity can be below the so-called “standard quantum limit” (for an oscillator this is half of the Plank constant). Moreover its transfer functions relative to the measured flux can be made to be about 10 mV/Φ 0 , which is an order of magnitude more than the best value for a conventional DC SQUIDs with a direct readout. We analyze here the voltage-to-flux, the phase-to-flux transfer functions and the main noise sources. We show that the experimental characteristics of a flux qubit, obtained in recent experiments, allow the use of a flux qubit as magnetometer with energy resolution close to the Planck constant.

arXiv:cond-mat/0608416•Europhysics Letters (EPL)•Feb 27, 2007•20 citations

Temperature-dependent performance of all-NbN DC-SQUID magnetometers

Quansheng Liu, Huiwu Wang, Qiyu Zhang +3 more

Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current–voltage and voltage–flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.

Applied Physics Letters•May 29, 2017•18 citations

Dual On-Chip SQUID Measurement Protocol for Flux Detection in Large Magnetic Fields

Josiah Cochran, Giovanni Franco-Rivera, Denghui Zhang +3 more

Sensitive magnetometers that can operate in high magnetic fields are essential for detecting magnetic resonance signals originating from small ensembles of quantum spins. Such devices have potential applications in quantum technologies, in particular quantum computing. We present a novel experimental setup implementing a differential flux measurement using two Direct-Current Superconducting QUantum Interference Device (DC-SQUID) magnetometers. The differential measurement allows for cancellation of background flux signals while enhancing sample signal. The developed protocol uses pulsed readout, which minimizes on-chip heating since sub-Kelvin temperatures are needed to preserve quantum spin coherence. Results of a proof of concept experiment are shown as well.

arXiv:2012.07559•IEEE Transactions on Applied Superconductivity•Jun 21, 2021•1 citation

Superconducting microwave magnetometer for absolute flux detection

Simon Günzler, Patrick Winkel, Rieger, Dennis +5 more

Superconducting quantum interference devices (SQUIDs) are among the most sensitive detectors for out-of-plane magnetic field components. However, due to their periodic response with short modulation period $M = 1 Φ_0$, determined by the magnetic flux quantum $Φ_0 \approx 2.068\times 10^{-15}\,\mathrm{Wb}$, it is difficult to infer the value of the magnetic flux unambiguously, especially in case the magnetic flux enclosed in the SQUID loop changes by many flux quanta. Here, we demonstrate that by introducing a second degree of freedom in the form of a second SQUID, we substantially enhance the modulation period $M$ of our device without sacrificing sensitivity. As a proof of concept, we implement our idea by embedding two asymmetric direct current SQUIDs into a common tank circuit. By measuring the reflection coefficient of the device, we extract the two lowest energy eigenfrequencies as a function of the external magnetic flux created by a superconducting field coil, from which we experimentally deduce a modulation period $M \geq 15 Φ_0$, as well as the magnetic offset-field $B_0 = 22\,\mathrm{nT}$ present in our experiment.

arXiv:2107.05929•Jul 13, 2021•3 citations

Tracing the characteristics of a flux qubit with a hysteretic dc-superconducting quantum interference device comparator

Maria Gabriella Castellano, F. Chiarello, Roberto Leoni +6 more

A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.

Journal of Applied Physics•Dec 4, 2003•4 citations

Proposal for a Beat Oscillating Superconducting Quantum Interference Device

Hisao Furukawa, Shinji Tomiyama, Itsuo Hatono +1 more

We describe a new dc-superconducting quantum interference device (SQUID) circuit of the FM type, which has a large coefficient for converting an applied magnetic flux into a frequency of MHz band or a lower band. The circuit consists of a SQUID amplifier composed of two stages, formed by a superconducting weak link and two dc-SQUID elements with nonhysteretic characteristics. In the first stage, the weak link and dc-SQUID elements are connected in parallel and operated by a common bias voltage. Since the respective elements oscillate with high frequencies by the ac Josephson effect, the two frequencies interact with each other, so that, the first stage generates a beat signal of a lower frequency. In the second stage, the other dc-SQUID element with a intrinsic flux gain enhances the beat signal generated during the first stage. A theoretical analysis of the circuit with computer simulation shows that the beat frequency is a periodical function of the magnetic flux, and the SQUID amplifier with two stages can improve the flux sensitivity.

Japanese Journal of Applied Physics•May 1, 1998•0 citations
We propose a novel device, based on a series of dc SQUIDs (direct current Superconducting QUantum Interference Devices), each one with different sensitive area, that can be used to perform absolute measurements of magnetic field. With this array, we overcome the limit of a single dc SQUID of being sensitive only to variations of the linked magnetic flux. The overall voltage-flux characteristic of our device, in fact, has a non-periodic shape that allows a clear identification of the point with zero magnetic field. We present a discussion of the working principle and of the main characteristics, which have been partially tested on a prototype.
A magnetometer based on the quantum properties of a superconducting flux qubit is proposed. The main advantage of this device is that its sensitivity can be below the so-called “standard quantum limit” (for an oscillator this is half of the Plank constant). Moreover its transfer functions relative to the measured flux can be made to be about 10 mV/Φ 0 , which is an order of magnitude more than the best value for a conventional DC SQUIDs with a direct readout. We analyze here the voltage-to-flux, the phase-to-flux transfer functions and the main noise sources. We show that the experimental characteristics of a flux qubit, obtained in recent experiments, allow the use of a flux qubit as magnetometer with energy resolution close to the Planck constant.
Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current–voltage and voltage–flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.
Sensitive magnetometers that can operate in high magnetic fields are essential for detecting magnetic resonance signals originating from small ensembles of quantum spins. Such devices have potential applications in quantum technologies, in particular quantum computing. We present a novel experimental setup implementing a differential flux measurement using two Direct-Current Superconducting QUantum Interference Device (DC-SQUID) magnetometers. The differential measurement allows for cancellation of background flux signals while enhancing sample signal. The developed protocol uses pulsed readout, which minimizes on-chip heating since sub-Kelvin temperatures are needed to preserve quantum spin coherence. Results of a proof of concept experiment are shown as well.
Superconducting quantum interference devices (SQUIDs) are among the most sensitive detectors for out-of-plane magnetic field components. However, due to their periodic response with short modulation period M=1Φ0M = 1 Φ_0M=1Φ0​, determined by the magnetic flux quantum Φ0≈2.068×10−15 WbΦ_0 \approx 2.068\times 10^{-15}\,\mathrm{Wb}Φ0​≈2.068×10−15Wb, it is difficult to infer the value of the magnetic flux unambiguously, especially in case the magnetic flux enclosed in the SQUID loop changes by many flux quanta. Here, we demonstrate that by introducing a second degree of freedom in the form of a second SQUID, we substantially enhance the modulation period MMM of our device without sacrificing sensitivity. As a proof of concept, we implement our idea by embedding two asymmetric direct current SQUIDs into a common tank circuit. By measuring the reflection coefficient of the device, we extract the two lowest energy eigenfrequencies as a function of the external magnetic flux created by a superconducting field coil, from which we experimentally deduce a modulation period M≥15Φ0M \geq 15 Φ_0M≥15Φ0​, as well as the magnetic offset-field B0=22 nTB_0 = 22\,\mathrm{nT}B0​=22nT present in our experiment.
A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.
We describe a new dc-superconducting quantum interference device (SQUID) circuit of the FM type, which has a large coefficient for converting an applied magnetic flux into a frequency of MHz band or a lower band. The circuit consists of a SQUID amplifier composed of two stages, formed by a superconducting weak link and two dc-SQUID elements with nonhysteretic characteristics. In the first stage, the weak link and dc-SQUID elements are connected in parallel and operated by a common bias voltage. Since the respective elements oscillate with high frequencies by the ac Josephson effect, the two frequencies interact with each other, so that, the first stage generates a beat signal of a lower frequency. In the second stage, the other dc-SQUID element with a intrinsic flux gain enhances the beat signal generated during the first stage. A theoretical analysis of the circuit with computer simulation shows that the beat frequency is a periodical function of the magnetic flux, and the SQUID amplifier with two stages can improve the flux sensitivity.