Physical Review A

Cavity ringdown heterodyne spectroscopy: High sensitivity with microwatt light power

Jun Ye, J. L. Hall

Published May 17, 2000• 52 citations
Publisher

Abstract

We present an ac heterodyne technique in cavity ringdown spectroscopy that permits $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$ absorption sensitivity with microwatt-level light power. Two cavity modes, one probing the empty cavity and the other probing intracavity absorption, are excited simultaneously but with their intensities temporally out of phase, with one mode decaying and the other rising. Heterodyne detection between the two modes reveals the dynamic time constants associated with the empty cavity and the additional intracavity gas absorption. The method offers a quick comparison between the on- and off-resonance information, a prerequisite to reaching the fundamental shot-noise limit. This simple and yet important improvement of cavity ringdown spectroscopy should lead to the enhanced performance of a wide range of applications.

DOI
10.1103/physreva.61.061802

Related papers

Frequency-switched heterodyne cavity ringdown spectroscopy

M. D. Levenson, Barbara A. Paldus, Thomas G. Spence +4 more

When the frequency of light coupled into a cavity is suddenly shifted, the radiation emanating from the input port of the previously excited cavity can beat with the reflection of the frequency-shifted input on the surface of a photodetector. When the beat frequency is stable, the time decay of the resulting optical heterodyne signal can be used to measure intracavity absorption spectra with near quantum-limited sensitivity.

Optics Letters•Jun 15, 2000•23 citations

TOWARDS THE ULTIMATE OPTICAL DETECTION SENSITIVITY: NEW SPECTROSCOPIC OPPORTUNITIES- AND A ZILLION NEW WAVELENGTH/FREQUENCY STANDARDS

J. L. Hall

High sensitivity detection of quantum absorption is demonstrated at a sensitivity of $1 \\times 10^{11}$ integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -$alpha^{*}$L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse $^{*}2/\\pi.3$) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm ($\\nu_{1} + 3 \\nu_{3}$), and recently, using a Nd:YAG source, from the HCCD P(5) line ($\\nu_{2} + 3 \\nu_{3}$) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz $\\pm 45$ kHz.

•Jan 1, 1996•0 citations

Dispersion and Cavity-Ringdown Spectroscopy

Kevin K. Lehmann

Cavity Ring Down Spectroscopy has become an important method in gas phase spectroscopy and its uses promise to expand. While previous investigators have considered the decay of the stored energy in the cavity ring down cell following short pulsed excitation, this paper considers the effects of pulse reshaping during cavity ring down. It is found that in order to properly model these effects, one must consider not only the mode dependent loss of the ring down cavity, but also dispersion that shifts the resonant modes of the cavity. Only by considering the latter effect does one get a "causal" result where the free induction decay signal of the absorber occurs after the excitation pulse. It is demonstrated that in the limit that the cavity round trip time is long compared to both the T 2 time of the intracavity absorber and the temporal width of the excitation pulse, the reshaping of the n'th pulse out of the ring down cavity is the same as the reshaping produced by free space propagation over a distance of (2 n + 1) L where L is the separation of the mirrors in the cell. However, when the absorber T 2 becomes comparable to or longer than the cavity round trip time, then discrete modes of the ring down cavity become important. A general expression for the output is given for the important case of a weak absorber, and changes in the output are computed for a single absorption line as a function of the ratio of T 2 to the cavity round trip time for several values of the optical thickness of the sample. Lastly, it is suggested that monitoring changes in the pulse shape of the cavity ring down signal provides a way to characterize an absorption spectrum on a frequency scale of the laser bandwidth down to the cavity free spectral range.

ACS symposium series•Apr 8, 1999•12 citations

The superposition principle and cavity ring-down spectroscopy

Kevin K. Lehmann, D. Romanini

Cavity ring-down is becoming a widely used technique in gas phase spectroscopy. It holds promise for further important extensions, which will lead to even more frequent use. However, we have found widespread confusion in the literature about the nature of coherence effects, especially when the optical cavity constituting the ring-down cell is excited with a short coherence length laser source. In this paper we use the superposition principle of optics to present a general and natural framework for describing the excitation of a ring-down cavity regardless of the relative values of the cavity ring-down time, the input pulse coherence time, or the dephasing time of absorption species inside the cavity. This analysis demonstrates that even in the impulsive limit the radiation inside a high finesse cavity can have frequency components only at the natural resonance frequencies of the cavity modes. As an immediate consequence, a sample absorption line can be detected only if it overlaps at least one of the cavity resonances. Since this point is of particular importance for high resolution applications of the technique, we have derived the same conclusion also in the time domain representation. Finally, we have predicted that it is possible to use this effect to do spectroscopy with a resolution much higher than that of the bandwidth of the excitation laser. In order to aid in the design of such experiments, expressions are derived for the temporal and spatial overlap of a Fourier transform limited input Gaussian beam with the TEMmn modes of the cavity. The expressions we derive for the spatial mode overlap coefficients are of general interest in applications where accurate mode matching to an optical cavity is required.

The Journal of Chemical Physics•Dec 15, 1996•199 citations

Optical feedback frequency stabilized cavity ring-down spectroscopy

Johannes Burkart, D. Romanini, S. Kassi

We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.

Optics Letters•Aug 4, 2014•66 citations

Doppler-free nonlinear absorption in ethylene by use of continuous-wave cavity ringdown spectroscopy

Christine R. Bucher, Kevin K. Lehmann, David F. Plusquellic +1 more

We report what we believe to be the first systematic study of Doppler-free, nonlinear absorption by use of cavity ringdown spectroscopy. We have developed a variant of cavity ringdown spectroscopy for the mid-infrared region between 9 and 11 microm, exploiting the intracavity power buildup that is possible with continuous-wave lasers. The infrared source consists of a continuous-wave CO2 laser with 1-mW tunable infrared sidebands that couple into a high-finesse stable resonator. We tune the sideband frequencies to observe a saturated, Doppler-free Lamb dip in the nu7, 11(1,10) <-- 11(2,10) rovibrational transition of ethylene (C2H4). Power studies of the Lamb dip are presented to examine the intracavity effects of saturation on the Lamb-dip linewidth, the peak depth, and the broadband absorption.

Applied Optics•Jun 20, 2000•58 citations
We present an ac heterodyne technique in cavity ringdown spectroscopy that permits 1\ifmmode×\else\texttimes\fi10\ensuremath−101\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}1\ifmmode×\else\texttimes\fi10\ensuremath−10 absorption sensitivity with microwatt-level light power. Two cavity modes, one probing the empty cavity and the other probing intracavity absorption, are excited simultaneously but with their intensities temporally out of phase, with one mode decaying and the other rising. Heterodyne detection between the two modes reveals the dynamic time constants associated with the empty cavity and the additional intracavity gas absorption. The method offers a quick comparison between the on- and off-resonance information, a prerequisite to reaching the fundamental shot-noise limit. This simple and yet important improvement of cavity ringdown spectroscopy should lead to the enhanced performance of a wide range of applications.
High sensitivity detection of quantum absorption is demonstrated at a sensitivity of 1times10111 \\times 10^{11}1times1011 integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -alpha∗alpha^{*}alpha∗L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse ∗2/pi.3^{*}2/\\pi.3∗2/pi.3) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm (nu1+3nu3\\nu_{1} + 3 \\nu_{3}nu1​+3nu3​), and recently, using a Nd:YAG source, from the HCCD P(5) line (nu2+3nu3\\nu_{2} + 3 \\nu_{3}nu2​+3nu3​) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz pm45\\pm 45pm45 kHz.
Cavity Ring Down Spectroscopy has become an important method in gas phase spectroscopy and its uses promise to expand. While previous investigators have considered the decay of the stored energy in the cavity ring down cell following short pulsed excitation, this paper considers the effects of pulse reshaping during cavity ring down. It is found that in order to properly model these effects, one must consider not only the mode dependent loss of the ring down cavity, but also dispersion that shifts the resonant modes of the cavity. Only by considering the latter effect does one get a "causal" result where the free induction decay signal of the absorber occurs after the excitation pulse. It is demonstrated that in the limit that the cavity round trip time is long compared to both the T 2 time of the intracavity absorber and the temporal width of the excitation pulse, the reshaping of the n'th pulse out of the ring down cavity is the same as the reshaping produced by free space propagation over a distance of (2 n + 1) L where L is the separation of the mirrors in the cell. However, when the absorber T 2 becomes comparable to or longer than the cavity round trip time, then discrete modes of the ring down cavity become important. A general expression for the output is given for the important case of a weak absorber, and changes in the output are computed for a single absorption line as a function of the ratio of T 2 to the cavity round trip time for several values of the optical thickness of the sample. Lastly, it is suggested that monitoring changes in the pulse shape of the cavity ring down signal provides a way to characterize an absorption spectrum on a frequency scale of the laser bandwidth down to the cavity free spectral range.
Cavity ring-down is becoming a widely used technique in gas phase spectroscopy. It holds promise for further important extensions, which will lead to even more frequent use. However, we have found widespread confusion in the literature about the nature of coherence effects, especially when the optical cavity constituting the ring-down cell is excited with a short coherence length laser source. In this paper we use the superposition principle of optics to present a general and natural framework for describing the excitation of a ring-down cavity regardless of the relative values of the cavity ring-down time, the input pulse coherence time, or the dephasing time of absorption species inside the cavity. This analysis demonstrates that even in the impulsive limit the radiation inside a high finesse cavity can have frequency components only at the natural resonance frequencies of the cavity modes. As an immediate consequence, a sample absorption line can be detected only if it overlaps at least one of the cavity resonances. Since this point is of particular importance for high resolution applications of the technique, we have derived the same conclusion also in the time domain representation. Finally, we have predicted that it is possible to use this effect to do spectroscopy with a resolution much higher than that of the bandwidth of the excitation laser. In order to aid in the design of such experiments, expressions are derived for the temporal and spatial overlap of a Fourier transform limited input Gaussian beam with the TEMmn modes of the cavity. The expressions we derive for the spatial mode overlap coefficients are of general interest in applications where accurate mode matching to an optical cavity is required.
We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.
We report what we believe to be the first systematic study of Doppler-free, nonlinear absorption by use of cavity ringdown spectroscopy. We have developed a variant of cavity ringdown spectroscopy for the mid-infrared region between 9 and 11 microm, exploiting the intracavity power buildup that is possible with continuous-wave lasers. The infrared source consists of a continuous-wave CO2 laser with 1-mW tunable infrared sidebands that couple into a high-finesse stable resonator. We tune the sideband frequencies to observe a saturated, Doppler-free Lamb dip in the nu7, 11(1,10) <-- 11(2,10) rovibrational transition of ethylene (C2H4). Power studies of the Lamb dip are presented to examine the intracavity effects of saturation on the Lamb-dip linewidth, the peak depth, and the broadband absorption.