Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

Doppler-free nonlinear absorption in ethylene by use of continuous-wave cavity ringdown spectroscopy

Christine R. Bucher, Kevin K. Lehmann, David F. Plusquellic, G. T. Fraser

Published Jun 20, 2000• 58 citations
Publisher

Abstract

We report what we believe to be the first systematic study of Doppler-free, nonlinear absorption by use of cavity ringdown spectroscopy. We have developed a variant of cavity ringdown spectroscopy for the mid-infrared region between 9 and 11 microm, exploiting the intracavity power buildup that is possible with continuous-wave lasers. The infrared source consists of a continuous-wave CO2 laser with 1-mW tunable infrared sidebands that couple into a high-finesse stable resonator. We tune the sideband frequencies to observe a saturated, Doppler-free Lamb dip in the nu7, 11(1,10) <-- 11(2,10) rovibrational transition of ethylene (C2H4). Power studies of the Lamb dip are presented to examine the intracavity effects of saturation on the Lamb-dip linewidth, the peak depth, and the broadband absorption.

DOI
10.1364/ao.39.003154

Related papers

Optical feedback frequency stabilized cavity ring-down spectroscopy

Johannes Burkart, D. Romanini, S. Kassi

We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.

Optics Letters•Aug 4, 2014•66 citations

Cavity ringdown heterodyne spectroscopy: High sensitivity with microwatt light power

Jun Ye, J. L. Hall

We present an ac heterodyne technique in cavity ringdown spectroscopy that permits $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$ absorption sensitivity with microwatt-level light power. Two cavity modes, one probing the empty cavity and the other probing intracavity absorption, are excited simultaneously but with their intensities temporally out of phase, with one mode decaying and the other rising. Heterodyne detection between the two modes reveals the dynamic time constants associated with the empty cavity and the additional intracavity gas absorption. The method offers a quick comparison between the on- and off-resonance information, a prerequisite to reaching the fundamental shot-noise limit. This simple and yet important improvement of cavity ringdown spectroscopy should lead to the enhanced performance of a wide range of applications.

Physical Review A•May 17, 2000•52 citations

Saturated absorption spectroscopy of acetylene molecules with an optical nanofiber

Masato Takiguchi, Yutaka Yoshikawa, Takayuki Yamamoto +2 more

We performed saturated absorption spectroscopy of acetylene (C₂H₂) ν₁ + ν₃ band transitions with an optical nanofiber (ONF). Owing to high-intensity light around the ONF, we observed a Lamb dip at relatively low-power laser (~10 mW) without a cavity. Our results showed that the simple ONF spectrometer is advantageous for performing saturation absorption spectroscopy and serves as a practical low-cost wavelength reference in the optical fiber communication band.

Optics Letters•Mar 29, 2011•29 citations

Sub-Doppler noise-immune cavity-enhanced optical heterodyne molecular spectrometry modeling: from Doppler broadening to cross-sideband resonances

Patrick Dupré

An analytical methodology is presented to calculate spectra provided by NICE-OHMS. It is based on the solutions of the equations of motion of an open two-blocked-level system performed in the frequency domain. The polychromaticity of the impinging electromagnetic field, furthermore, trapped inside a high-finesse cavity, is a potential source of induced resonances when this field interacts with a weakly absorbing nonlinear medium. These are optimal conditions to produce the well-established hole burning. However, the radio-frequency sidebands intrinsically associated with the NICE-OHMS technique require a specific treatment for describing both absorption and optical phase shift contributions. To validate the approach, numerical simulations of two transitions of C2H2 in the near-infrared range are discussed. The Doppler broadening-free cross-sideband resonances have been clearly characterized under the regime of moderate electromagnetically induced saturation. Comparison to experimental data available [Opt. Express16, 14689 (2008)OPEXFF1094-408710.1364/OE.16.014689] allowed us to assess the eligibility of the approach.

Journal of the Optical Society of America B•Apr 13, 2015•9 citations

Saturated absorption in NH3 demonstrated using a tuneable diode laser

D. E. Jennings

Saturation of molecular transitions using a tuneable diode laser has been demonstrated for the first time using a standing-wave-cavity configuration with the laser beam focused at the sample. Observed saturation effects in NH3 transitions near 888 cm−1 include sub-Doppler (Lamb-dip) resonances at the line center.

Applied Physics Letters•Sep 15, 1978•19 citations

Sub-Doppler resolution near-infrared spectroscopy at 128 μm with the noise-immune cavity-enhanced optical heterodyne molecular spectroscopy method

Tzu-Ling Chen, Yi-Wei Liu

We report on the sub-Doppler saturation spectroscopy of the nitrous oxide (N2O) overtone transition at 1.28 μm. This measurement is performed by the noise-immune cavity-enhanced optical heterodyne molecular spectroscopy technique based on the quantum-dot (QD) laser. A high intra-cavity power, up to 10 W, reaches the saturation limit of the overtone line using an optical cavity with a high finesse of 1.14(5)×105. At a pressure of several mTorr, the saturation dip is observed with a full width at half-maximum of about 2 MHz and a signal-to-noise ratio of 71. To the best of our knowledge, this is the first saturation spectroscopy of molecular overtone transitions in the 1.3 μm region. The QD laser is then locked to this dispersion signal with a stability of 15 kHz at 1 s integration time. We demonstrate the potential of the N2O as a marker because of its particularly rich spectrum at the vicinity of 1.28–1.30 μm where there are several important forbidden transitions of atomic parity violation measurements and the 1.3 μm O-band of optical communication.

arXiv:1705.05208•Optics Letters•Jun 15, 2017•10 citations
We report what we believe to be the first systematic study of Doppler-free, nonlinear absorption by use of cavity ringdown spectroscopy. We have developed a variant of cavity ringdown spectroscopy for the mid-infrared region between 9 and 11 microm, exploiting the intracavity power buildup that is possible with continuous-wave lasers. The infrared source consists of a continuous-wave CO2 laser with 1-mW tunable infrared sidebands that couple into a high-finesse stable resonator. We tune the sideband frequencies to observe a saturated, Doppler-free Lamb dip in the nu7, 11(1,10) <-- 11(2,10) rovibrational transition of ethylene (C2H4). Power studies of the Lamb dip are presented to examine the intracavity effects of saturation on the Lamb-dip linewidth, the peak depth, and the broadband absorption.
We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.
We present an ac heterodyne technique in cavity ringdown spectroscopy that permits $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$ absorption sensitivity with microwatt-level light power. Two cavity modes, one probing the empty cavity and the other probing intracavity absorption, are excited simultaneously but with their intensities temporally out of phase, with one mode decaying and the other rising. Heterodyne detection between the two modes reveals the dynamic time constants associated with the empty cavity and the additional intracavity gas absorption. The method offers a quick comparison between the on- and off-resonance information, a prerequisite to reaching the fundamental shot-noise limit. This simple and yet important improvement of cavity ringdown spectroscopy should lead to the enhanced performance of a wide range of applications.
An analytical methodology is presented to calculate spectra provided by NICE-OHMS. It is based on the solutions of the equations of motion of an open two-blocked-level system performed in the frequency domain. The polychromaticity of the impinging electromagnetic field, furthermore, trapped inside a high-finesse cavity, is a potential source of induced resonances when this field interacts with a weakly absorbing nonlinear medium. These are optimal conditions to produce the well-established hole burning. However, the radio-frequency sidebands intrinsically associated with the NICE-OHMS technique require a specific treatment for describing both absorption and optical phase shift contributions. To validate the approach, numerical simulations of two transitions of C2H2 in the near-infrared range are discussed. The Doppler broadening-free cross-sideband resonances have been clearly characterized under the regime of moderate electromagnetically induced saturation. Comparison to experimental data available [Opt. Express16, 14689 (2008)OPEXFF1094-408710.1364/OE.16.014689] allowed us to assess the eligibility of the approach.
We report on the sub-Doppler saturation spectroscopy of the nitrous oxide (N2O) overtone transition at 1.28 μm. This measurement is performed by the noise-immune cavity-enhanced optical heterodyne molecular spectroscopy technique based on the quantum-dot (QD) laser. A high intra-cavity power, up to 10 W, reaches the saturation limit of the overtone line using an optical cavity with a high finesse of 1.14(5)×105. At a pressure of several mTorr, the saturation dip is observed with a full width at half-maximum of about 2 MHz and a signal-to-noise ratio of 71. To the best of our knowledge, this is the first saturation spectroscopy of molecular overtone transitions in the 1.3 μm region. The QD laser is then locked to this dispersion signal with a stability of 15 kHz at 1 s integration time. We demonstrate the potential of the N2O as a marker because of its particularly rich spectrum at the vicinity of 1.28–1.30 μm where there are several important forbidden transitions of atomic parity violation measurements and the 1.3 μm O-band of optical communication.