Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Optical lattice clocks and frequency comparisons

Hidetoshi Katori

Published Jun 1, 2010• 0 citations
Publisher

Abstract

To date, optical clocks based on singly trapped ions and ultracold neutral atoms trapped in the Stark-shift-free optical lattices are regarded as promising candidates for future atomic clocks. Since 2006, “optical lattice clocks” have been evaluated close to the Cs clocks' uncertainty limit internationally. One of the essential experimental challenges in the development of “optical lattice clocks” is to find out the better lattice geometries as well as interrogated atom species (including their quantum statistics) that bring out the potential performance of the clock scheme, taking into account the collisional frequency shift, the Black body radiation (BBR) shift, the atomic multipolar and hyperpolarizability effects.

DOI
10.1109/cpem.2010.5544504

Related papers

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Spin- 1/2 Optical Lattice Clock

N. Lemke, Andrew D. Ludlow, Zeb W. Barber +7 more

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

arXiv:0906.1219•Physical Review Letters•Aug 3, 2009•281 citations

OPTICAL LATTICE CLOCK: SEVEN YEARS OF PROGRESS AND NEXT STEPS

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Spin-1/2 Optical Lattice Clock

N. Lemke, Andrew D. Ludlow, Zeb W. Barber +7 more

We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

•Jun 5, 2009•0 citations

DEVELOPMENT OF AN OPTICAL CLOCK BASED ON NEUTRAL STRONTIUM ATOMS HELD IN A LATTICE TRAP

E. A. Curtis, Yuri B. Ovchinnikov, Ian R. Hill +2 more

At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations
To date, optical clocks based on singly trapped ions and ultracold neutral atoms trapped in the Stark-shift-free optical lattices are regarded as promising candidates for future atomic clocks. Since 2006, “optical lattice clocks” have been evaluated close to the Cs clocks' uncertainty limit internationally. One of the essential experimental challenges in the development of “optical lattice clocks” is to find out the better lattice geometries as well as interrogated atom species (including their quantum statistics) that bring out the potential performance of the clock scheme, taking into account the collisional frequency shift, the Black body radiation (BBR) shift, the atomic multipolar and hyperpolarizability effects.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.
We experimentally investigate an optical clock based on 171^{171}171Yb (I=1/2I=1/2I=1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4×10−163.4 \times 10^{-16}3.4×10−16, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.
At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.