Review of Scientific Instruments

Ion imaging in a high-gradient magnetic guide

Varun Vaidya, Mallory Traxler, Cornelius Hempel, Rahul R. Mhaskar, Georg A. Raithel

Published Apr 1, 2010• 3 citations
Publisher

Abstract

We study a photoionization method to detect and image a narrow beam of cold atoms traveling along a high-gradient two-wire magnetic guide that is continuously on. Ions are accelerated in a compact acceleration region, directed through a drift region several centimeters in length, and detected using a position-sensitive ion detector. The potentials of several electrodes can be varied to adjust the imaging properties. Using ion trajectory simulations as well as experiments, we study the passage of the ions through the detection system, the magnification of the detection system, and the time-of-flight characteristics.

DOI
10.1063/1.3386583

Related papers

Continuous propagation and energy filtering of a cold atomic beam in a long high-gradient magnetic atom guide

Spencer E. Olson, Rahul R. Mhaskar, Georg A. Raithel

We demonstrate the continuous injection and propagation of a cold atomic beam in a high-gradient (up to $2.7\phantom{\rule{0.3em}{0ex}}\mathrm{kG}∕\mathrm{cm}$) magnetic guide of $1.7\phantom{\rule{0.3em}{0ex}}\mathrm{m}$ length. Continuous injection is accomplished using a side-loading scheme that involves a sequence of two modified magneto-optic traps. Methods are developed to measure the atomic-flow temperatures and the flux under steady-state conditions. In the high-gradient portion of the guide, the guided atomic beam has a transverse temperature of $420\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{K}\ifmmode\pm\else\textpm\fi{}40\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{K}$, a longitudinal temperature of $1\phantom{\rule{0.3em}{0ex}}\mathrm{mK}$, and an average velocity of order $1\phantom{\rule{0.3em}{0ex}}\mathrm{m}∕\mathrm{s}$. Using a radio-frequency current of a fixed frequency $\ensuremath{\nu}$ coupled directly into the guide wires, atoms exceeding a transverse energy of $h\ensuremath{\nu}$ can be continuously and selectively removed from the atomic beam.

Physical Review A•Mar 29, 2006•28 citations

Long, high -gradient magnetic atom guide and progress towards an atom laser.

Spencer E. Olson

The continuous injection and propagation of a cold atomic beam in a 1.7 m long high-gradient (up to 2.7 kG/cm) magnetic guide is demonstrated. Continuous injection is accomplished by side-loading a magnetic guide with atoms from a sequence of two modified magneto-optical traps. In the high-gradient portion of the guide, the guided atomic beam has a transverse temperature of 420 muK +/- 40 muK, a longitudinal temperature of 1 mK, and an average velocity of order 1 m/s. Essential for the characterization of this steady-state atomic beam, imaging methods compatible with the high field-gradients associated with this magnetic guide have been investigated and developed. By utilizing a probe laser tuned to an open transition, the fluorescence yield per atom is largely fixed throughout the trap volume, independent of the trapping field. This enables a reliable conversion of fluorescence images into atomic-density profiles. Using a fixed radio-frequency (nurf) current coupled directly onto the guide wires, continuous and selective removal of atoms with a transverse energy exceeding hnurf is demonstrated. This removal scheme is the essence of an rf filter, where the number of modes occupied by the atomic flow is reduced. Through sufficient rf-filtering, a near-single-mode guided atomic beam should be achievable, enabling basic atom-interferometric experiments. The extension of this fixed-frequency removal of atoms for continuous position-resolved evaporative cooling in a long magnetic guide is outlined. Employing an innovative gridless technique for performing Direct Simulation of rarefied gas dynamics via Monte Carlo (DSMC), the evaporative cooling process in a guided atomic beam has been simulated. Both fixed-frequency as well as variable-frequency evaporative cooling layouts have been explored and the results of these simulations are presented. The implementation of this gridless technique is presented and its benefits are briefly outlined. In parallel with the development of a continuous-wave atom laser, tools suited to manipulate cold atomic beams in atom guides have been explored. An atomic guide with a tunable aspect ratio, using rf-dressed state potentials, is presented.

•Jan 1, 2006•0 citations

Guiding of Rydberg atoms in a high-gradient magnetic guide

Mallory Traxler, Rachel Sapiro, Cornelius Hempel +3 more

We study the guiding of ${}^{87}$Rb 59$D$${}_{5/2}$ Rydberg atoms in a linear, high-gradient, two-wire magnetic guide. Time-delayed microwave ionization and ion detection are used to probe the Rydberg atom motion. We observe guiding of Rydberg atoms over a period of 5 ms following excitation. The decay time of the guided-atom signal is about five times that of the initial state. We attribute the lifetime increase to an initial phase of $l$-changing collisions and thermally induced Rydberg-Rydberg transitions. Detailed simulations of Rydberg-atom guiding reproduce most experimental observations and offer insight into the internal-state evolution.

arXiv:1202.5240•Physical Review A•Aug 20, 2012•3 citations

Imaging of neutral atomic beams

B. Sheehy, S-Q. Shang, Harold J. Metcalf +1 more

We have developed a method to image a beam of neutral atoms (chiefly usable for alkalis) that is essentially an extension to two dimensions of the usual hot wire method of detection. The beam of neutral atoms first passes through a a highly transparent, positively charged grid and then impinges on a heated grid of electroformed nickel with lower transparency and at ground potential. Atoms with ionization potential less than the work function of Ni that strike the heated grid are ionized at its surface and are then pushed through it by the 250-V/cm field produced by the voltage on the first grid. The ions are then accelerated through ~700 V to a pair of multichannel plates (MCPs) ~3 mm away where the single charged ion signal is amplified. The output electrons from the MCPs are accelerated by 1.7 kV to a phosphor screen ~3 mm away that glows when the electrons strike it. The phosphor screen is viewed by a TV camera whose output goes to a frame processor in a PC. The system has been used for studying transverse laser cooling (optical collimation) of a Rb beam done with diode lasers.

Annual Meeting Optical Society of America•Jan 1, 1989•0 citations

Toward an atom laser: Cold atoms in a long, high-gradient magnetic guide

Rahul R. Mhaskar

The propagation of an atomic beam through a 1.7 m long magnetic guide with magnetic field gradient of up to 2.7 kGauss/cm has been demonstrated. The guide is side-loaded with an atomic beam from a Pyramidal MOT Low-velocity Intense Source. The atomic beam observed at the end of the guide has a flux of 3×10e7 atoms/s with a velocity of 1.2 m/s, a transverse temperature of 420±40 μK and a longitudinal temperature of 1 mK. The guided atomic beam was mode-filtered by selective removal of high-energy atoms using radio-frequency coupling to magnetically untrapped states. We found that the phase-space density of the atomic beam was very low for evaporative cooling to be functional. An imaging technique was developed to characterize the guided atomic flow in the presence of a high magnetic field gradient. This technique utilizes the open-channel transition to obtain nearly constant photon yield per atom independent of the location of the atom in the guide, providing a mapping of the fluorescence images to the atomic-density profiles. This technique was theoretically studied using Quantum Monte-Carlo Simulations and validated. A Zeeman slower was constructed and characterized to be used as the primary source of atoms to the magnetic guide. The Zeeman slower output atomic beam has a flux of 3×10e11 atoms/s at a velocity of 40 m/s. We have designed a new injection scheme to transfer atoms from the Zeeman slower to the magnetic guide efficiently. The details of a new method to evaporatively cool atoms in the magnetic guide using surface adsorption are described. Finally, a new guide geometry based on a spiral structure is discussed.

•Jan 1, 2008•1 citation

A high resolution ion microscope for cold atoms

Markus Stecker, Hannah Schefzyk, József Fortágh +1 more

We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.

arXiv:1701.02915•New Journal of Physics•Apr 13, 2017•29 citations
We study a photoionization method to detect and image a narrow beam of cold atoms traveling along a high-gradient two-wire magnetic guide that is continuously on. Ions are accelerated in a compact acceleration region, directed through a drift region several centimeters in length, and detected using a position-sensitive ion detector. The potentials of several electrodes can be varied to adjust the imaging properties. Using ion trajectory simulations as well as experiments, we study the passage of the ions through the detection system, the magnification of the detection system, and the time-of-flight characteristics.
We demonstrate the continuous injection and propagation of a cold atomic beam in a high-gradient (up to 2.7kG∕cm2.7\phantom{\rule{0.3em}{0ex}}\mathrm{kG}∕\mathrm{cm}2.7kG∕cm) magnetic guide of 1.7m1.7\phantom{\rule{0.3em}{0ex}}\mathrm{m}1.7m length. Continuous injection is accomplished using a side-loading scheme that involves a sequence of two modified magneto-optic traps. Methods are developed to measure the atomic-flow temperatures and the flux under steady-state conditions. In the high-gradient portion of the guide, the guided atomic beam has a transverse temperature of $420\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{K}\ifmmode\pm\else\textpm\fi{}40\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{K}$, a longitudinal temperature of 1mK1\phantom{\rule{0.3em}{0ex}}\mathrm{mK}1mK, and an average velocity of order 1m∕s1\phantom{\rule{0.3em}{0ex}}\mathrm{m}∕\mathrm{s}1m∕s. Using a radio-frequency current of a fixed frequency $\ensuremath{\nu}$ coupled directly into the guide wires, atoms exceeding a transverse energy of $h\ensuremath{\nu}$ can be continuously and selectively removed from the atomic beam.
The continuous injection and propagation of a cold atomic beam in a 1.7 m long high-gradient (up to 2.7 kG/cm) magnetic guide is demonstrated. Continuous injection is accomplished by side-loading a magnetic guide with atoms from a sequence of two modified magneto-optical traps. In the high-gradient portion of the guide, the guided atomic beam has a transverse temperature of 420 muK +/- 40 muK, a longitudinal temperature of 1 mK, and an average velocity of order 1 m/s. Essential for the characterization of this steady-state atomic beam, imaging methods compatible with the high field-gradients associated with this magnetic guide have been investigated and developed. By utilizing a probe laser tuned to an open transition, the fluorescence yield per atom is largely fixed throughout the trap volume, independent of the trapping field. This enables a reliable conversion of fluorescence images into atomic-density profiles. Using a fixed radio-frequency (nurf) current coupled directly onto the guide wires, continuous and selective removal of atoms with a transverse energy exceeding hnurf is demonstrated. This removal scheme is the essence of an rf filter, where the number of modes occupied by the atomic flow is reduced. Through sufficient rf-filtering, a near-single-mode guided atomic beam should be achievable, enabling basic atom-interferometric experiments. The extension of this fixed-frequency removal of atoms for continuous position-resolved evaporative cooling in a long magnetic guide is outlined. Employing an innovative gridless technique for performing Direct Simulation of rarefied gas dynamics via Monte Carlo (DSMC), the evaporative cooling process in a guided atomic beam has been simulated. Both fixed-frequency as well as variable-frequency evaporative cooling layouts have been explored and the results of these simulations are presented. The implementation of this gridless technique is presented and its benefits are briefly outlined. In parallel with the development of a continuous-wave atom laser, tools suited to manipulate cold atomic beams in atom guides have been explored. An atomic guide with a tunable aspect ratio, using rf-dressed state potentials, is presented.
We study the guiding of 87{}^{87}87Rb 59DDD5/2{}_{5/2}5/2​ Rydberg atoms in a linear, high-gradient, two-wire magnetic guide. Time-delayed microwave ionization and ion detection are used to probe the Rydberg atom motion. We observe guiding of Rydberg atoms over a period of 5 ms following excitation. The decay time of the guided-atom signal is about five times that of the initial state. We attribute the lifetime increase to an initial phase of lll-changing collisions and thermally induced Rydberg-Rydberg transitions. Detailed simulations of Rydberg-atom guiding reproduce most experimental observations and offer insight into the internal-state evolution.
We have developed a method to image a beam of neutral atoms (chiefly usable for alkalis) that is essentially an extension to two dimensions of the usual hot wire method of detection. The beam of neutral atoms first passes through a a highly transparent, positively charged grid and then impinges on a heated grid of electroformed nickel with lower transparency and at ground potential. Atoms with ionization potential less than the work function of Ni that strike the heated grid are ionized at its surface and are then pushed through it by the 250-V/cm field produced by the voltage on the first grid. The ions are then accelerated through ~700 V to a pair of multichannel plates (MCPs) ~3 mm away where the single charged ion signal is amplified. The output electrons from the MCPs are accelerated by 1.7 kV to a phosphor screen ~3 mm away that glows when the electrons strike it. The phosphor screen is viewed by a TV camera whose output goes to a frame processor in a PC. The system has been used for studying transverse laser cooling (optical collimation) of a Rb beam done with diode lasers.
The propagation of an atomic beam through a 1.7 m long magnetic guide with magnetic field gradient of up to 2.7 kGauss/cm has been demonstrated. The guide is side-loaded with an atomic beam from a Pyramidal MOT Low-velocity Intense Source. The atomic beam observed at the end of the guide has a flux of 3×10e7 atoms/s with a velocity of 1.2 m/s, a transverse temperature of 420±40 μK and a longitudinal temperature of 1 mK. The guided atomic beam was mode-filtered by selective removal of high-energy atoms using radio-frequency coupling to magnetically untrapped states. We found that the phase-space density of the atomic beam was very low for evaporative cooling to be functional. An imaging technique was developed to characterize the guided atomic flow in the presence of a high magnetic field gradient. This technique utilizes the open-channel transition to obtain nearly constant photon yield per atom independent of the location of the atom in the guide, providing a mapping of the fluorescence images to the atomic-density profiles. This technique was theoretically studied using Quantum Monte-Carlo Simulations and validated. A Zeeman slower was constructed and characterized to be used as the primary source of atoms to the magnetic guide. The Zeeman slower output atomic beam has a flux of 3×10e11 atoms/s at a velocity of 40 m/s. We have designed a new injection scheme to transfer atoms from the Zeeman slower to the magnetic guide efficiently. The details of a new method to evaporatively cool atoms in the magnetic guide using surface adsorption are described. Finally, a new guide geometry based on a spiral structure is discussed.
We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.