Optics Letters

Atomic vapor cells for chip-scale atomic clocks with improved long-term frequency stability

Svenja A. Knappe, Vladislav P. Gerginov, Peter D. D. Schwindt, Vishal Shah, H. G. Robinson, Leo W. Hollberg, John E. Kitching

Published Sep 15, 2005• 223 citations
Publisher

Abstract

A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume 1 mm3, containing 87Rb and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of 6 x 10(-12) at 1000 s of integration was measured. The long-term drift of the F=1, mF=0-->F=2, mF=0 hyperfine frequency of atoms in these cells is below 5 x 10(-11)/day.

DOI
10.1364/ol.30.002351

Related papers

Microfabricated alkali atom vapor cells

Li‐Anne Liew, Svenja A. Knappe, John Moreland +3 more

We describe the fabrication of chip-sized alkali atom vapor cells using silicon micromachining and anodic bonding technology. Such cells may find use in highly miniaturized atomic frequency references or magnetometers. The cells consist of cavities etched in silicon, with internal volumes as small as 1 mm3. Two techniques for introducing cesium and a buffer gas into the cells are described: one based on chemical reaction between cesium chloride and barium azide, and the other based on direct injection of elemental cesium within a controlled anaerobic environment. Cesium optical absorption and coherent population trapping resonances were measured in the cells.

Applied Physics Letters•Apr 1, 2004•377 citations

Micromachined alkali atom vapor cells for chip-scale atomic clocks

Li‐Anne Liew, Svenja A. Knappe, John Moreland +3 more

This paper describes the fabrication of chip-scale alkali atom vapor cells, for use in highly miniaturized atomic frequency references, using silicon micromachining and anodic bonding technology. The cells consist of silicon cavities with internal volume ranging from a few mm/sup 3/ to less than 1 mm/sup 3/. The cells were filled with cesium and nitrogen buffer gas either by chemical reaction of cesium chloride and barium azide, or by direct injection of elemental cesium within a controlled anaerobic environment. Cesium optical absorption spectra were obtained from the cells, and coherent population trapping resonances with linewidths of about 1 kHz were measured.

IEEE International Conference on Micro Electro Mechanical Systems (MEMS)•Aug 2, 2004•15 citations

Microfabricated Alkali Atom Vapor Cells for Chip Scale Atomic Clock

M.-Z. Huang, Jiashan Zhu, Guangfeng Shi +2 more

In this paper we present a novel fabrication technique for coherent population trapping based chip-sized alkali vapor cells. There are two cavities in the cell design, one is a reaction cavity for alkali dispenser and the other one is a working cavity for alkali storage. An alkali dispenser pill is placed in the reaction cavity and subsequently reacted to obtain pure alkali material. The alkali atoms can be transferred into the working cavity in vapor form once the cell is heated up to 70 degree. Since alkali reacts with many materials and cannot be handled in air, our method provides a low cost and high reproducible way to fabricate highly miniaturized vapor cells. Silicon micromachining and glass-Si-glass three-layer anodic bonding technology is applied to introduce alkali atoms and a buffer gas into the cell and effectively seal this environment within the cell. A rubidium vapor cell is demonstrated using our design. The cell size is 5×4×1.6 mm 3 , with hermetic seal leakage <5e −9 atm cc/s. Modulated optical absorption spectrum of the cell is obtained and matched with pure rubidium atom, indicating the suitability of these cells for use in highly miniaturized atomic frequency references based on CPT excitation scheme. In addition, the entire process is fabricated at the wafer level, with subsequent dicing into individual cells.

Annual Conference of the Chinese Society of Micro-Nano Technology (CSMNT)•Nov 22, 2017•0 citations

Microfabricated Atomic Clocks at NIST

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +5 more

This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.

•Dec 1, 2004•3 citations

The Microfabricated Alkali Vapor Cell with High Hermeticity for Chip-Scale Atomic Clock

Shuo Jia, Zhiyuan Jiang, Binbin Jiao +4 more

Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.

Applied Sciences•Jan 3, 2022•21 citations

Microfabricated cells for chip-scale atomic clock based on coherent population trapping: Fabrication and investigation

Ермак Сергей Викторович, V. V. Semenov, Пятышев Евгений Нилович +5 more

A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.

St Petersburg Polytechnical University Journal Physics and Mathematics•Mar 1, 2015•10 citations
A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume 1 mm3, containing 87Rb and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of 6 x 10(-12) at 1000 s of integration was measured. The long-term drift of the F=1, mF=0-->F=2, mF=0 hyperfine frequency of atoms in these cells is below 5 x 10(-11)/day.
We describe the fabrication of chip-sized alkali atom vapor cells using silicon micromachining and anodic bonding technology. Such cells may find use in highly miniaturized atomic frequency references or magnetometers. The cells consist of cavities etched in silicon, with internal volumes as small as 1 mm3. Two techniques for introducing cesium and a buffer gas into the cells are described: one based on chemical reaction between cesium chloride and barium azide, and the other based on direct injection of elemental cesium within a controlled anaerobic environment. Cesium optical absorption and coherent population trapping resonances were measured in the cells.
This paper describes the fabrication of chip-scale alkali atom vapor cells, for use in highly miniaturized atomic frequency references, using silicon micromachining and anodic bonding technology. The cells consist of silicon cavities with internal volume ranging from a few mm/sup 3/ to less than 1 mm/sup 3/. The cells were filled with cesium and nitrogen buffer gas either by chemical reaction of cesium chloride and barium azide, or by direct injection of elemental cesium within a controlled anaerobic environment. Cesium optical absorption spectra were obtained from the cells, and coherent population trapping resonances with linewidths of about 1 kHz were measured.
In this paper we present a novel fabrication technique for coherent population trapping based chip-sized alkali vapor cells. There are two cavities in the cell design, one is a reaction cavity for alkali dispenser and the other one is a working cavity for alkali storage. An alkali dispenser pill is placed in the reaction cavity and subsequently reacted to obtain pure alkali material. The alkali atoms can be transferred into the working cavity in vapor form once the cell is heated up to 70 degree. Since alkali reacts with many materials and cannot be handled in air, our method provides a low cost and high reproducible way to fabricate highly miniaturized vapor cells. Silicon micromachining and glass-Si-glass three-layer anodic bonding technology is applied to introduce alkali atoms and a buffer gas into the cell and effectively seal this environment within the cell. A rubidium vapor cell is demonstrated using our design. The cell size is 5×4×1.6 mm 3 , with hermetic seal leakage <5e −9 atm cc/s. Modulated optical absorption spectrum of the cell is obtained and matched with pure rubidium atom, indicating the suitability of these cells for use in highly miniaturized atomic frequency references based on CPT excitation scheme. In addition, the entire process is fabricated at the wafer level, with subsequent dicing into individual cells.
This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.
Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.
A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.