Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

RESEARCH OF FREQUENCY STANDARDS IN SIOM — ATOMIC FREQUENCY STANDARDS BASED ON COHERENT STORAGE

B. YAN, He Cheng, Y. S., W. Z. ZHANG, L. LIU, Y. Z. WANG

Published May 1, 2009• 0 citations
Publisher

Abstract

In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.

DOI
10.1142/9789812838223_0038

Related papers

Formation of Ramsey fringes based on pulsed coherent light storage

Bo Yan, Yisheng Ma, Yuzhu Wang

We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low $Q$ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.

arXiv:0810.0623•Physical Review A•Jun 11, 2009•6 citations

LASER COOLING OF ATOMS AND ITS APPLICATION IN FREQUENCY STANDARDS

Vladilen S Letokhov, Vladimir G. Minogin

The results of studies into the laser cooling of atoms have been summarized and the possibilities of application of cold atoms in frequency standards have been considered. It has been shown that the optical frequency standard on the basis of laser-cooled atoms Mg, Ca or Sr may have the long-term stability of about 10-15.

Le Journal de Physique Colloques•Dec 1, 1981•1 citation

High-stability compact atomic clock based on isotropic laser cooling

François-Xavier Esnault, David Holleville, Nicolas Rossetto +2 more

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

Physical Review A•Sep 29, 2010•84 citations

Ramsey-coherent population trapping Cs atomic clock based on lin∥lin optical pumping with dispersion detection*

Pengfei Cheng, Jianwei Zhang, Lijun Wang

A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.

Chinese Physics B•Jul 1, 2019•9 citations

Investigations on continuous and pulsed interrogation for a CPT atomic clock

N. Castagna, Rodolphe Boudot, Stéphane Guérandel +3 more

We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Feb 1, 2009•65 citations

Study of Pulsed Optically Pumped Rb Frequency Standard

Shougang Zhang

The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.

Wuhan Daxue xuebao. Xinxi kexue ban•Jan 1, 2011•0 citations
In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.
We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low QQQ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.
We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.
A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.
We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.
The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.