arXiv:0810.0623 · Physical Review A

Formation of Ramsey fringes based on pulsed coherent light storage

Bo Yan, Yisheng Ma, Yuzhu Wang

Published Jun 11, 2009• 6 citations
arXivHTMLPDF

Abstract

We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low $Q$ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.

DOI
10.1103/physreva.79.063820

Related papers

RESEARCH OF FREQUENCY STANDARDS IN SIOM — ATOMIC FREQUENCY STANDARDS BASED ON COHERENT STORAGE

B. YAN, He Cheng, Y. S. +3 more

In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Light shifts in a pulsed cold-atom coherent-population-trapping clock

E. Blanshan, Simon Rochester, Elizabeth A. Donley +1 more

Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in applications ranging from network synchronization to inertial navigation. A coherent-population-trapping clock featuring laser-cooled $^{87}\mathrm{Rb}$ atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the frequency biases can be minimized and controlled. Here we characterize the light shift in a cold-atom coherent-population-trapping clock, explaining observed shifts in terms of phase shifts that arise during the formation of dark-state coherences combined with optical-pumping effects caused by unwanted incoherent light in the interrogation spectrum. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that would reduce clock frequency uncertainty from light shifts to a fractional frequency level of $\ensuremath{\Delta}\ensuremath{\nu}/\ensuremath{\nu}=4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ per 100 kHz of laser frequency uncertainty.

Physical Review A•Apr 10, 2015•44 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•89 citations

High contrast transparent ramsey fringes using microwave pulses interaction with atomic coherent state in warm rubidium vapor

Yisheng Ma Yisheng, Jianliao Deng Jianliao Deng, Zhengfeng Hu Zhengfeng Hu +2 more

High contrast transparent Ramsey fringes are observed using double microwave pulses interaction with the prepared atomic coherent state in a warm 87 Rb vapor with mixture buffer gases in a closed cell.The Ramsey fringes are generated by the pulsed technique, a strong coupling light pulse and a weak signal light pulse are applied to prepare the atomic coherent state, followed by the application of double microwave pulses to interact with the atomic coherent state.Afterwards, the light pulses are applied again with weaker intensity and detecting the signal transmission is delected.The central line of the transparent Ramsey fringes has narrow linewidth of 125 Hz and high contrast of 21%.The light shift is dramatically reduced since the interrogating process is not involved the light field, and the cavity pulling effect is negligible due to the low Q requirement, which is promising for building small, compact, and stable atomic clocks.

Chinese Optics Letters•Jan 1, 2013•1 citation

Optical Ramsey interference and its performance in D1 line excitation in rubidium vapor for implementation of a vapor cell clock

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky +1 more

Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 10, 2011•6 citations

Prospect for development of a pulsed CPT Raman Ramsey clock using atomic vapor

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky +1 more

The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 11, 2010•2 citations
We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low QQQ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.
In this paper we proposed a frequency standard based on pulsed coherent storage (PCS), the basic idea of the PCS scheme is combining the information storage technique with the optical pumping method. It shows that the Ramsey pattern is printed on the coherence of the atom states, then is detected in the form of the retrieval light. The proposed PCS frequency standards are free of light shifts, low Q requirement, high signal contrast and low noise background. The estimated frequency stability is 2 × 10 -14 in 1 second. Meanwhile we report the progress in laser cooling of atoms in an integrating sphere, some experimental results are given. This cooling method provides a robust source which is suitable to construct a compact PCS clock.
Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in applications ranging from network synchronization to inertial navigation. A coherent-population-trapping clock featuring laser-cooled 87Rb^{87}\mathrm{Rb}87Rb atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the frequency biases can be minimized and controlled. Here we characterize the light shift in a cold-atom coherent-population-trapping clock, explaining observed shifts in terms of phase shifts that arise during the formation of dark-state coherences combined with optical-pumping effects caused by unwanted incoherent light in the interrogation spectrum. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that would reduce clock frequency uncertainty from light shifts to a fractional frequency level of $\ensuremath{\Delta}\ensuremath{\nu}/\ensuremath{\nu}=4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ per 100 kHz of laser frequency uncertainty.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
High contrast transparent Ramsey fringes are observed using double microwave pulses interaction with the prepared atomic coherent state in a warm 87 Rb vapor with mixture buffer gases in a closed cell.The Ramsey fringes are generated by the pulsed technique, a strong coupling light pulse and a weak signal light pulse are applied to prepare the atomic coherent state, followed by the application of double microwave pulses to interact with the atomic coherent state.Afterwards, the light pulses are applied again with weaker intensity and detecting the signal transmission is delected.The central line of the transparent Ramsey fringes has narrow linewidth of 125 Hz and high contrast of 21%.The light shift is dramatically reduced since the interrogating process is not involved the light field, and the cavity pulling effect is negligible due to the low Q requirement, which is promising for building small, compact, and stable atomic clocks.
Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.
The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.